VistaLab Technologies - MLA Micro D-Tipper
Manufactured by VistaLab Technologies
Micro D-Tipper pipettes use a smooth two-stroke action (with overblow) to achieve repeatable results and dependable...
Micro D-Tipper pipettes use a smooth two-stroke action (with overblow) to achieve repeatable results and dependable performance on microvolume sample sizes. Made of precision engineered aluminum and stainless steel, these pipettes are easy to use and require a simple upward lift on the pipette bonnet to eject used pipette tips. In-lab calibration is performed with minimal effort.
Active Questions & AnswersAsk a Question
There are no current Discussions
Pipettes Service ProvidersView All (10)
Documents & ManualsView All Documents
Features
There are no Features available.
General Specifications
There are no General Specifications available.
Series Modals
VistaLab Technologies - 10µL pipette
[+] View Model Specifications| Channel(s) | 1 |
| Pipette Accuracy | ±1.00% |
| Pipette Precision | 1.00% |
| Pipette Type | Manual Air Displacement |
| Pipette Volume Type | Fixed |
| Additional Model Specifications |
VistaLab Technologies - 2µL pipette
[+] View Model Specifications| Pipette Accuracy | ±2.00% |
| Pipette Precision | 2.50% |
| Pipette Type | Manual Air Displacement |
| Pipette Volume Type | Fixed |
| Additional Model Specifications |
VistaLab Technologies - 3µL pipette
[+] View Model Specifications| Channel(s) | 1 |
| Pipette Accuracy | ±1.50% |
| Pipette Precision | 2.00% |
| Pipette Type | Manual Air Displacement |
| Pipette Volume Type | Fixed |
| Additional Model Specifications |
VistaLab Technologies - 4µL pipette
[+] View Model Specifications| Channel(s) | 1 |
| Pipette Accuracy | ±1.50% |
| Pipette Precision | 2.00% |
| Pipette Type | Manual Air Displacement |
| Pipette Volume Type | Fixed |
| Additional Model Specifications |
VistaLab Technologies - 5µL pipette
[+] View Model Specifications| Channel(s) | 1 |
| Pipette Accuracy | ±1.00% |
| Pipette Precision | 1.50% |
| Pipette Type | Manual Air Displacement |
| Pipette Volume Type | Fixed |
| Additional Model Specifications |
VistaLab Technologies - 6µL pipette
[+] View Model Specifications| Channel(s) | 1 |
| Pipette Accuracy | ±1.00% |
| Pipette Precision | 1.50% |
| Pipette Type | Manual Air Displacement |
| Pipette Volume Type | Fixed |
| Additional Model Specifications |
VistaLab Technologies - 7µLpipette
[+] View Model Specifications| Channel(s) | 1 |
| Pipette Accuracy | ±1.00% |
| Pipette Precision | 1.50% |
| Pipette Type | Manual Air Displacement |
| Pipette Volume Type | Fixed |
| Additional Model Specifications |
VistaLab Technologies - 8µL pipette
[+] View Model Specifications| Channel(s) | 1 |
| Pipette Accuracy | ±1.00% |
| Pipette Precision | 1.50% |
| Pipette Type | Manual Air Displacement |
| Pipette Volume Type | Fixed |
| Additional Model Specifications |
VistaLab Technologies - 9µL pipette
[+] View Model Specifications| Channel(s) | 1 |
| Pipette Accuracy | ±1.00% |
| Pipette Precision | 1.50% |
| Pipette Type | Manual Air Displacement |
| Pipette Volume Type | Fixed |
| Additional Model Specifications |