Sysmex - FPIA 3000
Manufactured by Sysmex
Particle Characterization System
The Sysmex FPIA-3000 enables reliable, repeatable and routine characterization of particle size distributions and particle shape distributions using automated imaging techniques.
Particle shape information is generated from the analysis of a large number of particles, displays of size and shape data are supported by images of all particles to provide further visual understanding of the measurement data. Particle shape provides an additional parameter to understand the source of manufacturing variations.
Particle shape information is generated from the analysis of a large number of particles, displays of size and shape data are supported by images of all particles to provide further visual understanding of the measurement data. Particle shape provides an additional parameter to understand the source of manufacturing variations.
Active Questions & AnswersAsk a Question
There are no current Discussions
Particle Size Analyzers Service ProvidersView All (2)
Documents & ManualsView All Documents
Features of FPIA 3000
- Measuring range: Measures materials from 0.8µm to 300µm.
- Sample types: For the measurement of emulsions, suspensions. Compatible sheath reagents include particle sheath reagent—aqueous based, methanol, ethanol, isopropyl alcohol and ethylene glycol solution (25%)
- User friendly software: Predefined measurement and analysis procedures ensure measurement reproducibility. Shape characterization using multiple shape parameters. Unique particle size vs. circularity scattergram provides sample finger printing. Particle classification facility. Data generated includes particle size distributions, particle shape distributions, and concentration. Stores images of particles with size data.
- Applications: Biotechnology, Ceramics, Graphite, Abrasives, Toners, Metal Powders, Polymers, Yeast, Algae, Protein Crystals and Pharmaceutical materials e.g. Actives and excipients.
- Controlled sample presentation: Sheath flow ensures all particles are separated and in focus. Unique flow cell design for unprecedented particle image quality and consistent particle orientation.
- Ease of use: Fully automated for ease of use. High through put – typical measurement completed in < 3 minutes.
General Specifications
There are no General Specifications available.
Additional Specifications
Measurement technique: Automated image analysis—flow cytometry
Light source: White light stroboscope (60Hz)
Detector: CCD (charge-coupled device)
Standard sample volume: 5ml
Measurement time: 2.5 minutes
Dimensions: (Main Unit) 900(w) x 455(h) x 475(d)
Weight: 59.5kg