MilliporeSigma - Elix Large 20/35/70/100
Manufactured by MilliporeSigma
Type 2 analytical-grade water
Produce Up to 4000 L/day of Pure Water
Elix systems are designed to produce up to 4000 L/day of Type 2 analytical-grade water from potable tap feedwater to meet or exceed the relevant standards defined by CLSI, ISO® 3696 / BS 3997 and the European and US Pharmacopoeia.
One Complete Purification and Control Unit
Elix systems can be integrated into a centralized system, providing total control of all parameters within the system itself as well as within the external pure water distribution loop.
Elix systems are designed to produce up to 4000 L/day of Type 2 analytical-grade water from potable tap feedwater to meet or exceed the relevant standards defined by CLSI, ISO® 3696 / BS 3997 and the European and US Pharmacopoeia.
One Complete Purification and Control Unit
Elix systems can be integrated into a centralized system, providing total control of all parameters within the system itself as well as within the external pure water distribution loop.
Active Questions & AnswersAsk a Question
Water Purification Service ProvidersView All (6)
Documents & ManualsView All Documents
Features of Elix Large 20/35/70/100
- Total control of all functions, operating parameters and standard accessory components within the Elix system itself and within the external pure water distribution loop
- Patented Elix electrodeionization module continuously regenerates ion-exchange resins
- Built-in resistivity and TOC (Total Organic Carbon) monitoring to ensure water quality
- No additional softeners are required for most feedwater conditions
- Easy-to-replace pretreatment packs, tailored to the feedwater source Built-in UV lamp for bacteria-sensitive applications
- Built-in UV lamp for bacteria-sensitive applications
- Systems contain integrated control functions for distribution loop components (pump, UV lamp, ASM, TOC and resistivity meters)
Applications Elix product water is suitable for the following applications:
- Microbiological media preparation
- Buffer preparation
- Hydroponics
- Manufacturing chemical and biochemical reagents
- Pharmaceutical use of purified water
- Feed for laboratory equipment
- Feed to Milli-Q and Super-Q ultrapure water systems
General Specifications
There are no General Specifications available.
Series Modals
MilliporeSigma - Elix 100
[+] View Model SpecificationsFlow Rate | 100 L/hr |
Water Purification Method | RO |
ASTM Type | ASTM Type II |
TOC | 30 ppb |
Depth | 17.4 in |
Height | 28.9 in |
Width | 26.1 in |
Weight | 137 lbs (operational) |
Additional Model Specifications | Power Supply: 117 V/60 Hz, 10 A, (10 A Slo-Blo® fuse) 230 V/50 Hz, 5 A, (10 A Slo-Blo fuse) 110 V/50/60 Hz, 10 A, (10 A Slo-Blo fuse) System Performance Water recovery: up to 50% Water resistivity*: > 5 MΩ-cm Water conductivity: 99.9% * [CO2] 5 MΩ-cm* (typically 10 -15 MΩ-cm) Conductivity: 50 %) Total Chlorine level: Millipore Application Specialist will determine pretreatment required Fouling index: Millipore Application Specialist will determine pretreatment required Flow rate > 5 l/min at 2 bar (1.3 gal/min at 29 psi) |
MilliporeSigma - Elix 20
[+] View Model SpecificationsFlow Rate | 20 L/hr |
Water Purification Method | RO |
ASTM Type | ASTM Type II |
TOC | 30 ppb |
Depth | 17.4 in |
Height | 28.9 in |
Width | 26.1 in |
Weight | 99 lbs (operational) |
Additional Model Specifications | Power Supply: 117 V/60 Hz, 10 A, (10 A Slo-Blo® fuse) 230 V/50 Hz, 5 A, (10 A Slo-Blo fuse) 110 V/50/60 Hz, 10 A, (10 A Slo-Blo fuse) System Performance Water recovery: up to 30% Water resistivity*: > 5 M&Omeag;-cm Water conductivity: 99.9% * [CO2] 5 MΩ-cm* (typically 10 -15 MΩ-cm) Conductivity: 50 %) Total Chlorine level: Millipore Application Specialist will determine pretreatment required Fouling index: Millipore Application Specialist will determine pretreatment required Flow rate > 5 l/min at 2 bar (1.3 gal/min at 29 psi). |
MilliporeSigma - Elix 35
[+] View Model SpecificationsFlow Rate | 35 L/hr |
Water Purification Method | RO |
ASTM Type | ASTM Type II |
TOC | 30 ppb |
Depth | 17.4 in |
Height | 28.9 in |
Width | 26.1 in |
Weight | 106 lbs (operational) |
Additional Model Specifications | Power Supply: 117 V/60 Hz, 10 A, (10 A Slo-Blo® fuse) 230 V/50 Hz, 5 A, (10 A Slo-Blo fuse) 110 V/50/60 Hz, 10 A, (10 A Slo-Blo fuse) System Performance Water recovery: up to 40% Water resistivity*: > 5 MΩ-cm Water conductivity: 99.9% * [CO2 5 MΩ-cm* (typically 10 -15 MΩ-cm) Conductivity: Less than 0.2 µS/cm* (typically 0.067 - 0.10 µS/cm) Bacterial count: 50 %) Total Chlorine level: Millipore Application Specialist will determine pretreatment required Fouling index: Millipore Application Specialist will determine pretreatment required |
MilliporeSigma - Elix 70
[+] View Model SpecificationsFlow Rate | 70 L/hr |
Water Purification Method | RO |
ASTM Type | ASTM Type II |
TOC | 30 ppb |
Depth | 17.4 in |
Height | 28.9 in |
Width | 26.1 in |
Weight | 123 lbs (operational) |
Additional Model Specifications | Power Supply: 117 V/60 Hz, 10 A, (10 A Slo-Blo® fuse) 230 V/50 Hz, 5 A, (10 A Slo-Blo fuse) 110 V/50/60 Hz, 10 A, (10 A Slo-Blo fuse) System Performance Water recovery: up to 50% Water resistivity*: > 5 MΩ-cm Water conductivity: 99.9% * [CO2] 5 MΩ-cm* (typically 10 -15 MΩ-cm) Conductivity: 50 %) Total Chlorine level: Millipore Application Specialist will determine pretreatment required Fouling index: Millipore Application Specialist will determine pretreatment required Flow rate > 5 l/min at 2 bar (1.3 gal/min at 29 psi) |