Netzsch - TG 449 F3 Jupiter®
Manufactured by Netzsch
The thermobalance for every application - robust and upgradeable
The TG 449 F3 Jupiter® is the workhorse for thermogravimetric analyses of a moderate to high sample weights from -150°C into the high temperature range of 2000°C.
The vertical design with top-loaded samples ensures total protection of the balance, which is on the bottom, through accurate flow of the purge and protective gases in a natural vertical path to the top, with optimal conditions for coupling FTIR and MS gas analysis systems to the heated furnace outlet.
The TG sample carriers are always equipped with a thermocouple for direct measurement of the temperature at the sample.
The high capacity of the balance along with constant resolution over the entire weighing range provide the best conditions for using the wide variety of ceramic or metallic sample crucibles and pans in different shapes and sizes.
Of course, vacuum-tight construction providing for pure atmospheres goes without saying.
The TG 449 F3 Jupiter® is designed for upgrading to simultaneous TG-DSC or simultaneous TGA-DTA. The TGA sample carriers can be exchanged with TGA-DSC or TGA-DTA sample carriers in a matter of seconds so that a very cost-effective upgrade can be made at any time into a full-fledged, universal STA.
The TG 449 F3 Jupiter® is one of the versatile TGA systems for routine use in material research and development as well as in quality assurance – primarily in the area of inorganics.
The vertical design with top-loaded samples ensures total protection of the balance, which is on the bottom, through accurate flow of the purge and protective gases in a natural vertical path to the top, with optimal conditions for coupling FTIR and MS gas analysis systems to the heated furnace outlet.
The TG sample carriers are always equipped with a thermocouple for direct measurement of the temperature at the sample.
The high capacity of the balance along with constant resolution over the entire weighing range provide the best conditions for using the wide variety of ceramic or metallic sample crucibles and pans in different shapes and sizes.
Of course, vacuum-tight construction providing for pure atmospheres goes without saying.
The TG 449 F3 Jupiter® is designed for upgrading to simultaneous TG-DSC or simultaneous TGA-DTA. The TGA sample carriers can be exchanged with TGA-DSC or TGA-DTA sample carriers in a matter of seconds so that a very cost-effective upgrade can be made at any time into a full-fledged, universal STA.
The TG 449 F3 Jupiter® is one of the versatile TGA systems for routine use in material research and development as well as in quality assurance – primarily in the area of inorganics.
Active Questions & AnswersAsk a Question
1Replies
Startup Temperature Problem
1Replies
Reactive Gas Exhaust not Escaping
Need Equipment Support?
Documents & ManualsView All Documents
Features of TG 449 F3 Jupiter®
- Switch valve for 2 purge gases and 1 protective gas
- Mass flow control for 3 gas channels (optional)
- Vacuum-tight assembly up to 10-2 mbar
- c-DTA® for the calculated DTA-signal, ideal for temperature calibration at TG applications
- TGA-DSC and TGA-DTA sample carriers for real simultaneous operation
- Automatic sample changer (ASC) for up to 20 samples and references (option)
- Coupling with FTIR, MS and GC-MS over a heatable adapter (option)
- Extension with unique PulseTA® system (option)
General Specifications
Temperature Range | -150 to 2000 °C |
Additional Specifications
Heating and cooling rates: 0.001 K/min ... 50 K/min (dependent on furnace)
Weighing range: 35000 mg
TGA resolution: 1 µg
Atmospheres: inert, oxidizing, reducing, static, dynamic