Metrohm - 859 Titrotherm
Manufactured by Metrohm
USB-enabled thermometric titrator with one measuring input each for a Thermoprobe and a potentiometric sensor as well as four MSB connections
859 Titrotherm is a USB-enabled thermometric titrator with one measuring input each for a Thermoprobe and a potentiometric sensor as well as four MSB connections for 800 Dosino® and stirrers. Titrotherm software, a Thermoprobe and a USB connecting cable for a PC are also included.
What is thermometric titration?
Titration is the oldest and most widespread method used in analytical chemistry. For a long time now, potentiometric sensors (indicator electrodes) have been used to cover a wide range of applications in the titration field. As a result, potentiometric titration has become an established analytical method and features many standards.
The electrochemical potential is only one of the possible ways of following a chemical reaction. A far more universal parameter is the reaction enthalpy.
Every chemical reaction is accompanied by a change in enthalpy (_H). As long as the reaction takes place, this results in either an increase (exothermal reaction) or decrease (endothermal reaction) in the temperature of the sample solution. For a simple reaction this means that the increase or reduction in temperature depends on the converted amount of substance.
What is thermometric titration?
Titration is the oldest and most widespread method used in analytical chemistry. For a long time now, potentiometric sensors (indicator electrodes) have been used to cover a wide range of applications in the titration field. As a result, potentiometric titration has become an established analytical method and features many standards.
The electrochemical potential is only one of the possible ways of following a chemical reaction. A far more universal parameter is the reaction enthalpy.
Every chemical reaction is accompanied by a change in enthalpy (_H). As long as the reaction takes place, this results in either an increase (exothermal reaction) or decrease (endothermal reaction) in the temperature of the sample solution. For a simple reaction this means that the increase or reduction in temperature depends on the converted amount of substance.
Active Questions & AnswersAsk a Question
Recent Questions & Answers
Asked byhalfaoui
Titrators Service ProvidersView All (5)
Documents & Manuals
There are no Documents or Manuals available.
Features of 859 Titrotherm
- Proven method
- Easy learning and easy carrying-out of thermometric titration through incorporation of the method in the tiamoTM titration software
- Problem solver for difficult samples that cannot be titrated potentiometrically
- Rapid results
- No sensor calibration required
- Maintenance-free sensor
- Robust method for routine work
- Well suited for aggressive media
- One sensor for all applications
- No membrane or diaphragm problems
General Specifications
| Titrator Type | Thermometric |