Features of 231
  • Precise 402 Syringe Pump assures accuracy of injection volumes     
  • 402 Syringe Pump delivers volumes from 1 mL to 99 mL, allows selection of flow rates to compensate for different sample viscosities     
  • Task-oriented software for fast and easy building of injection protocols     
  • Can be configured for use in a sample prep GPC or GPC/SPE system
General Specifications
Cross Contamination0.0001 % with liquid level detection and recommended needle rinsing parameters; <0.005% without liquid level detection
Depth 18.3 in
Height14.5 in
Width 13 in
Power Requirements 100–120 V, 60 Hz / 200–240 V, 50 Hz
Weight13 kg
Additional Specifications

Manufacturing Standards: Meets applicable safety and EMC certification standards; UL and CE certified     
Analog Input: One analog signal (10 or 100 mV); convertible as fifth contact input     
Arm Speed: X/Y: 25 cm/sec (9.8 in./sec)    
Z upward: 12.5 cm/sec (4.9 in./sec)    
Z downward: 9 cm/sec (3.5 in./sec)     
Available Sample Loop: 20 µL     
Available Valves: Rheodyne 7010, Rheodyne 7413     
Communication Interface: RS-232 or GSIOC; Four inputs, four outputs, three relay outputs and two 12V power supplies     
Environmental Conditions: Indoor use    
Altitude: up to 2000 m    
Temperature range: 5–40°C    
Air pressure: 75–105 kPa    
Pollution degree: 1 or 2, in accordance with IEC 66    
Humidity: Maximum relative humidity 80% for temperatures up to 31°C, decreasing linearly to 50% relative humidity at 40°C     
Injection Volume From 2 µL to 5 mL with partial loop filling of 7010 valve; from 0.5 to 2 µL with 7413 valve     
Liquid Contact Materials: 316L stainless steel or titanium, FEP, PTFE, PEEK, PP, PI     
Maximum Number of Sample Vessels: 231 XL: 120 (6 x 32 mm or 7 x 40 mm) tubes or 2 microplates    
232 XL/233 XL: 540 (7 x 40 mm or 10 x 75 mm) tubes or 9 microplates     
Minimum Sample Volume: 10 µL, for four 1 µL injections, with peak area variations of less than 0.8%     
Sample Loading Method Direct introduction into a loop filler port allowing partial and total loop filling at selected flow rate     
Software Via Gilson Trilution™ LC Software     
Syringe Capacity (402 Syringe Pump) 100, 250 or 500 µL; 1, 5, 10 or 25 mL     
Transfer Flow Rate Selectable from 3 to 1600 µL/sec (0.2–96 mL/min)     
Dimensions:(w x d x h)     
231 XL: 33 x 46.5 x 23 cm (13 x 18.3 x 14.5 in.)    
232 XL/233 XL: 51.5 x 62 x 23 cm (20.3 x 24.4 x 14.5 in.)     
Weight:     
231 XL: 13 kg (29.3 lbs.)    
232 XL/233 XL: 17 kg (38.3 lbs.)     
    
† Contact Gilson Customer Service to learn what methods and conditions were used to obtain the values.