This product is Discontinued
Molecular Devices - Flexstation II
Manufactured by Molecular Devices
Scanning Fluorometer with Integrated Fluid Transfer Workstation
The Molecular Devices FlexStation II is a benchtop scanning fluorometer and integrated fluid transfer workstation capable of conducting endpoint, kinetic, lambda scan and well scan experiments in a multi-well plate format (6, 12, 24, 48 and 96-well) and fluidics transfer experiments in 96-well format. The FlexStation II is ideal for measuring the activity of Gq-coupled receptors via the detection of intracellular calcium release. In addition, kits are available for the measurement of fatty acid uptake, cyclic GMP and AMP levels, potassium ion channel flux, and membrane potential. The dual monochromator optical bench design allows the user to choose multiple wavelengths and to optimize excitation and emission wavelengths for most fluorometric assays.
Allow the user to obtain real-time kinetic data milliseconds before and after fluid transfer events. The dual monochromator optical bench design enables the user to choose multiple wavelengths and to optimize both excitation and emission wavelengths for most fluorometric assays.
Allow the user to obtain real-time kinetic data milliseconds before and after fluid transfer events. The dual monochromator optical bench design enables the user to choose multiple wavelengths and to optimize both excitation and emission wavelengths for most fluorometric assays.
Active Questions & AnswersAsk a Question
Recent Questions & Answers
Asked byTheLabSquad
Microplate Readers Service ProvidersView All (12)
Documents & Manuals
There are no Documents or Manuals available.
Features of Flexstation II
- Wavelength Range 360-850 nm
- Homogeneous, kinetic and cell-based fluorometric assays
- Assay development/ screening tool for functional cellular assays
- Dual monochromator optical design
- Luminescence Capability
- Fluorescence Photometric Excitation wavelength range: 250-850 nm
General Specifications
Depth | 40 cm |
Height | 49 cm |
Width | 58 cm |
Sample Formats | 6-, 12-, 24-, 48-, 96-, 384- well |
Additional Specifications
Fluorescence Photometric
Emission Wavelength Range: 375-850 nm
Excitation Wavelength Range: 250-850 nm
Scanning Increments: 1 nm
Fluidics (96 well plate)
Max Volume: 8Ch. 200µL
Dispense Max. Rate: 8Ch. 208µL/sec.
Precision at 50µL: 8Ch. 2%CV
Precision at 5µL: 8Ch. 8% CV
Read Time: 96 well in < 15 seconds
Single Well Read Time Frequency: 20 Hz
Shaker Time: 0 to 999 seconds