This product is Discontinued

Gilson - FC 206 Fraction Collector

Manufactured by  Gilson
Follow this Equipment

Gilson's FC 206 is a high-flow fraction collector, ideal for large-scale preparative work.

Gilson's FC 206 is a high-flow fraction collector, ideal for large-scale preparative work. Enables collection of up to 40 fractions at flow rates from 200 mL/min. to 800 mL/min. with the addition of high-flow accessories.
Active Questions & AnswersAsk a Question

Recent Questions & Answers

Need Equipment Support?

Request Support
Documents & Manuals

There are no Documents or Manuals available.

Features of FC 206 Fraction Collector

• Fits easily into a fume hood; separate keypad for operator safety    • Allows collection into both tubes and large bottles (up to several liters)    • Capable of time, peak and combined modes

General Specifications

There are no General Specifications available.

Additional Specifications

Manufacturing Standards  
Meets applicable safety and EMC certification standards; UL and CE certified   
3-way Valves 3-port, PTFE, 50 µL dead volume, up to 100 mL/min   
Communication Interface RS-232 or GSIOC; Two electrical inputs for start/stop and pause/resume; three electrical outputs for event marker, safety and programmable   
Detector Input ±10 mV, 100 mV, 1V or 10V full scale   
Environmental Conditions Indoor use  
Altitude: up to 2000 m  
Temperature range: 5–40°C  
Air pressure: 75–105 kPa  
Pollution degree: 1 or 2, in accordance with IEC 66  
Humidity: Maximum relative humidity 80% for temperatures up to 31°C, decreasing linearly to 50% relative humidity at 40°C   
Keypad Two-line, 24-character display. Five soft keys; STOP, HELP, ESCAPE, CLEAR and 0–9 numeric hard keys   
Maximum Flow Rate 200 mL/min (standard configuration); 800 mL/min with high-flow accessories   
Maximum Number of Sample Vessels 108 tubes (3-mL)  
40 large bottles (several liters)   
Method Storage Up to 9 files; lock/unlock, delete/copy   
Multiple-Cycle Operation Up to 999 cycles; for repetitive injection of same sample or automatic injection of different samples. Possible to overlap multiple injections   
Number of Racks Holds one rack   
Operating Modes Manual, Peak, Peak + Time, Time, Time Prog. and Time + Prog.   
Peak Detection Up to 99 selected peaks, positive or negative, with automatic tracking of baseline drift. Peak parameters: threshold level and maximum width at peak base. Time constant: 8 values from 0.2 to 30 seconds   
Power Requirements Frequency: 50–60 Hz  
Voltage: 100–120 or 220–240V; mains voltage fluctuations not to exceed ±10% of the nominal voltage   
Programmable Time Units From 0.01 to 999.99 minutes   
Software Via Gilson UniPoint™ System Software   
Time-Based Programming Up to 20 collection windows and 20 drain steps   
Dimensions (w x d x h) 33 x 15.5 x 24.5 cm (13 x 6.1 x 9.6 in.)   
Weight 8 kg (17.6 lbs.)