Gilson - UniPoint System Software
UniPoint™ System Software is an extremely powerful and flexible chromatography software package.
Active Questions & AnswersAsk a Question
Recent Questions & Answers
Updated byalmhde
Need Equipment Support?
Documents & ManualsView All Documents
Features of UniPoint System Software
True multitasking capabilities:
- Control multiple systems simultaneously from a single computer
- Edit UniPoint Software methods or re-analyze your data during a chromatography run
- Utilize other software while controlling your HPLC system
- Liquid handling capabilities for reformatting, diluting, etc.
- Versatile and flexible injection techniques
- Control of peripheral devices via RS-232
- Injection and fraction collection on one hardware platform
- Re-inject collected fractions into analytical system for purity check and estimate concentration
- Use multiple variables to customize operations and methods
- Easily add switching valves for multiple columns and multiple mobile phases
- 2-D chromatography
- Preparative injection and collection to 200 mL/min with an unlimited collection volume
- Multiple detector signals with a single run
Graphical sample tracking offers several time-saving features:
- Powerful sample tracking
- View a single peak of the plot
- Overlay traces by simply pointing and clicking
- Sample description files are easily imported from and exported to external spreadsheets for fast, accurate file exchange
- Automated re-injection of collected fractions directly from the fraction sites with no manual intervention
- The interactive screen allows you to click on a fraction tube/well, peak or sample location; the screen automatically updates corresponding windows
Electronic Record Management features:
- Fully validated
- Electronic signatures and workflow capabilities
- Automatic versioning of records
- Help ensure GMP, GLP and 21 CFR Part 11 compliance
- Security integrated with Microsoft® Windows®-based security
General Specifications
Depth | 17.5 cm |
Height | 18 cm |
Width | 15 cm |
Weight | 4 kg |
Additional Specifications
Manufacturing Standards Meets applicable safety and EMC certification standards; UL and CE certified
Communication Interface RS-232 or GSIOC; Two TTL-compatible inputs for control of start/stop and direction of flow and one analog input (0–5V) for variable control of motor speed
Environmental Conditions Indoor use
Altitude: up to 2000 m
Temperature range: 5–40°C
Air pressure: 75–105 kPa
Pollution degree: 1 or 2, in accordance with IEC 66
Humidity: Maximum relative humidity 80% for temperatures up to 31°C, decreasing linearly to 50% relative humidity at 40°C
Flow Rate Standard flow rates (1, 2, 4, or 8 channels): 0.3 µL/min–30 mL/min at a maximum pressure of 0.5 MPa.
High flow rates (2 or 4 channels): 1 mL/min–220 mL/min at a maximum pressure of 0.3 MPa
Head Speed Continuous adjustment from 0 to 48 rpm by 0.01 rpm increments up to 9.99 rpm and by 0.1 rpm increments above 10 rpm
Motor Speed Stability 0.5% for any variation of line voltage, torque, or temperature
Peristaltic Tubing Diameter Standard model: 0.25–4 mm (ID)
High-Flow model: 2–8 mm (ID)
Power Requirements Frequency: 47–63 Hz
Voltage: 90–132 or 180–264V; mains voltage fluctuations not to exceed ±10% of the nominal voltage
Consumption: Full load 45W at 220V; no load 35W at 220V
Pump Heads Standard model: 1-, 2-, 4-, or 8-channel heads with 10 stainless steel rollers per head
High-Flow model: 2- or 4-channel heads with five stainless steel rollers per head