On a tight budget and looking for a reliable, easy-to-use coulometric Karl Fischer titrator?
Then look no further than the AQUACOUNTER® AQ-300. With state-of-the-art performance features, like a fritless cell option, the AQ-300 offers the same fast and accurate results you've come to expect from other AQUACOUNTER® products.
Comes with DVD training movie, plasticized Quick-Start guide for use in the lab, paper and pdf manual. Also included, complete accessories, download software, RS-232 cable, and AQUACOUNTER® KF Reagent starter kit.
Then look no further than the AQUACOUNTER® AQ-300. With state-of-the-art performance features, like a fritless cell option, the AQ-300 offers the same fast and accurate results you've come to expect from other AQUACOUNTER® products.
Comes with DVD training movie, plasticized Quick-Start guide for use in the lab, paper and pdf manual. Also included, complete accessories, download software, RS-232 cable, and AQUACOUNTER® KF Reagent starter kit.
Active Questions & AnswersAsk a Question
Titrators Service ProvidersView All (5)
Documents & Manuals
There are no Documents or Manuals available.
Features of AQ-300
- Six (6) built-in calculation modes accommodate solid, liquid and gas samples.
- One-touch calculations - including statistics package!
- Four (4) files of preset conditions can be stored in memory.
- Balance and computer interfaces for GLP and ISO documentation. Instant recall of data for up to 20 samples.
- Built-in detector monitors titration status.
- Choice of ion exchange membrane or fritted cell system.
- Choice of thermal printer or impact printer.
- Free software for downloading titration results to a laptop or PC; includes the correct RS-232 cable.
- Competive price.
General Specifications
| Depth | 270 mm |
| Height | 300 mm |
| Width | 310 mm |
| Power Requirements | AC100 - 240V, 50/60 Hz & 100VA |
| Weight | 5 kg |
| Titrator Type | Karl Fischer Coulometric |
Additional Specifications
Electrolytic control method: Constant current electrolysis, intermittent electrolysis in the vicinity of the end point only
Titration control method: AC polarization potential difference detection method (1) Automatic stop at endpoint after elapsed INTERVAL time (INTERVAL: Max. 99 sec.) (2) Titration time settings system (T-TIMER: Max. 99 min.)
Accuracy: CV of 0.3 % With water-methanol (1 mg H2O/mL),1 g is measured 10 times
Measuring range: 10Μg H2O - 99mg H2O
Required measuring time: FAST 50 sec/mg H2O SLOW: 100 sec/mg H2O
Titration cell capacity: 150 mL
File function: 4 files for titration parameters