Roche - cobas e 411
Bench top analyzer for heterogeneous immunoassays.
For immunological analysis of serum or plasma.
Active Questions & AnswersAsk a Question
Need Equipment Support?
Documents & ManualsView All Documents
Features of cobas e 411
Easy to operate The customized keyboard and easy-to-learn software make training and operation simple and keep user involvement to a minimum.
Unique programming-by-loading concept Barcode-based data entry is carried out automatically by loading reagents, controls and calibrators onto the system – a rapid, robust and safe procedure.
STAT facilities for urgent samples cobas e 411 disk system features two STAT sample positions that can be accessed at any time, delivering results rapidly in response to clinicians‘ requests . The cobas e 411 rack system features a STAT port for immediate access emergency testing.
Innovative technology Novel Electrochemiluminescence (ECL) technology provides superior analytical performance. Increased sensitivity means that extremely low levels of antigen, as well as subtle changes in levels, can be detected. The very wide measuring range facilitates cost and time efficient testing by reducing the need to dilute and repeat samples.
General Specifications
Power Requirements | 100 –120 VAC 50/60 Hz single phase or 200–240 VAC 50/60 Hz single phase |
Peak Power | 800 VA |
Additional Specifications
System:
Fully automated, random access system for immunoassay analysis.
It is available as both, a disk system and a rack system.
System components:
Analytical module including Window XP embedded operated touch screen PC
Sample handling module: rack or disk operated
Sample throughput:
Up to 88 samples/hr (theoretical max)
Test throughput:
Up to 88 tests/hr (theoretical max)
Number of channels:
18 channels/reagent slots for up to 18 different assays
Programmable parameters:
Max 60 assays definable via 2D-barcode (programming by loading)
Sample types:
Serum, Plasma, Urine
Sample input/output
Load/unload capacity:
30 samples (disk)
75 samples on 15 racks
Rack:
RD standard 5 position rack
Rack types:
Routine, STAT, Control, Calibrator
STAT handling:
Any unoccupied position on the sample disk,
dedicated STAT port on rack feeder
Sample container types
Primary tubes:
5–10 ml; 16x100,16x75, 13x100, 13x75mm
Sample cup:
2,5 ml
Micro cup:
not allowed
Cups on tube:
Cup on top of a 16 x 75/100 mm tube
Sample volume:
10 to 50 Μl per test, depending on assay protocol
Operating conditions
Ambient temperature:
18 to 32 °C (64.4 °F to 89.6 °F)
Ambient humidity:
20% to 80%
Noise Output:
60 dbA (stand-by mode)
63 dbA (avg. during operation)
Physical dimensions
Width:
1200 to 1700 mm (disk/rack)
Depth:
730 to 950 mm (disk/rack)
Height:
560 mm (w/o PC unit)
Weight:
Approx. 170 kg (disk) and 210 kg (rack)