Malvern Panalytical - Parsum
Parsum Probes use Spatial Filter Velocimetry to deliver in situ, real-time size and velocity measurements for solid particles suspended in a pneumatic
Parsum Probes use Spatial Filter Velocimetry to deliver in situ, real-time size and velocity measurements for solid particles suspended in a pneumatic or gravity flow gas stream. Robust, dustproof and waterproof they measure particles in the size range 50-6000 µm with velocities from 0.01-50 m/s and are suitable for any industrial environment.
Parsum IPP 70-S
A robust inline particle sizing probe for real-time measurement
Parsum IPP 70-SE
An intrinsically safe in-line particle sizing probe for real-time measurement
Parsum IPP 70-SL
A long, robust particle sizing probe for real-time measurement
Parsum IPP 80-P
Specifically designed for the pharmaceutical and food industries, the Parsum IPP80 is an intrinsically safe probe delivering real-time particle size and particle velocity measurements for solid particles in the range from 50µm up to 6mm in size. Its simple, dustproof and waterproof probe design enables direct monitoring of fluidized bed and high shear mixing and granulation processes.
The Parsum IPP 80 is used in food and pharmaceutical applications for endpoint detection in batch granulation process, and for real time monitoring of continuous manufacturing processes. It is applied in unit operations such as grinding, agglomeration, granulation, coating and sieving.
Active Questions & AnswersAsk a Question
There are no current Discussions
Particle Size Analyzers Service ProvidersView All (2)
Documents & ManualsView All Documents
Features of Parsum
- Lightweight and easy to install for rapid integration into new and existing processing plant.
- Wide dynamic range for particles from 50 - 6000µm travelling at up to 50m/s.
- Reproducible measurement at high solids loadings even with irregularly moving particles - ideal for fluidized bed monitoring.
- Real-time measurement and feedback via comprehensive, customizable software.
- No sampling or calibration required.
- Range of accessories enables application for abrasive, greasy, sticky and adherent particles.
General Specifications
There are no General Specifications available.
Series Modals
Malvern Panalytical - Parsum IPP 70-S
[+] View Model SpecificationsPower Requirements | 110 |
Measurement | 50 to 6000 µm |
Light Source | 670nm |
Additional Model Specifications | Power: (V, Hz, VA) 110/230V, 50/60Hz Software: IPP V7.14 Minimum computer specification: Min 2 GB Ram Operating platforms: Win XP, Vista, Win 7 Measurement type 1: Particle size Measurement range: 50-6000µm Measurement principle: Spatial Filter Velocimetry Measurement type 2: Particle Velocity Measurement range: 0,01 – 50m/s Measurement principle: Spatial Filter Velocimetry Light source: 670nm Laser safety: Class 1 Operating environment: Temperature: 10°C -100°C Humidity: 35% - 80% non-condensing Enclosure rating: IP 65 |
Malvern Panalytical - Parsum IPP 70-SE Discontinued
[+] View Model SpecificationsPower Requirements | 110 |
Measurement | 50 to 6000 µm |
Light Source | 670nm |
Additional Model Specifications | Software: IPP V7.14 Minimum computer specification: Min 2 GB Ram Operating platforms: Win XP, Vista, Win 7 Measurement type 1: Particle size Measurement range: 50-6000µm Measurement principle: Spatial Filter Velocimetry Measurement type 2: Particle Velocity Measurement range: 0,01 – 50m/s Measurement principle: Spatial Filter Velocimetry Light source: 670nm Laser safety: Class 1 Operating environment: Temperature: 10°C – 60°C Humidity: 35% - 80% non-condensing Enclosure rating: IP 65 |
Malvern Panalytical - Parsum IPP 70-SL Discontinued
[+] View Model SpecificationsPower Requirements | 110 |
Measurement | 50 to 6000 µm |
Light Source | 670nm |
Additional Model Specifications | Software: IPP V7.14 Minimum computer specification: Min 2 GB Ram Operating platforms: Win XP, Vista, Win 7 Measurement type 1: Particle size Measurement range: 50-6000µm Measurement principle: Spatial Filter Velocimetry Measurement type 2: Particle Velocity Measurement range: 0,01 – 50m/s Measurement principle: Spatial Filter Velocimetry Light source: 670nm Laser safety: Class 1 Operating environment: Temperature: 10°C – 60°C Humidity: 35% - 80% non-condensing Enclosure rating: IP 65 |