High Sensitivity Differential Scanning Calorimeter (DSC)

Newly released High Sensitivity Differential Scanning Calorimeter X-DSC7000 has the new technology which comprises new sensor and new furnace. New sensor achieves the tripled sensor performance by the multiple thermocouples (compared to the existing products of Hitachi High-Tech Science). The new furnace which is composed of 3 layer insulation wall and the optimized heating and cooling structure suppresses the influence of baseline fluctuation, and increases temperature following capability.
Active Questions & AnswersAsk a Question

There are no current Discussions

Need Equipment Support?

Request Support
Documents & Manuals

There are no Documents or Manuals available.

Features of X-DSC7000

Highest sensitivity, superior baseline stability and repeatability by the new technology    New sensor achieves tripled sensor performance by the multiple thermocouples (compared to the products of Hitachi High-Tech Science). New furnace which is composed of 3 layer insulation wall and the optimized heating and cooling structure suppresses the influence of baseline fluctuation, and increases temperature following capability. These achieve world’s leading performance of DSC sensitivity less than 0.1ΜW ?RMS noise less than 0.05ΜW? and baseline repeatability ±5ΜW. It enables the more reliable.   

Improved Temperature Control Performance    New furnace delivers the expanded temperature range up to -80?500°C in case of using electrical cooling unit. Cooling control performance enables down to -50°C at 10°C/min linearly. Automatic LN2 gas cooling unit improves the cooling efficiency and the amount of LN2 used decreased.   

Easy Cooling Unit Exchange    Electrical cooling unit and automatic LN2 gas cooling unit can be exchanged by users easily depend on the temperature range and the measurement purpose.   

Excellent Expandability and Option Line-Up    The auto-sampler can be attached easily.    The reliable routine measurement can be achieved by the combination of the auto-sampler and the mass controller. The photochemical reaction measurement is achieved by attaching UV irradiation unit. The sample observation unit can be attached.

General Specifications

There are no General Specifications available.

Additional Specifications

Temperature Range: -170 to 725°C    
Measurement Range: ±100mW    
Sensitivity: 0.1µW    
Scan Rate: 0.01 to 100°C/min