Agilent Technologies - 7100 Capillary Electrophoresis System
Highest sensitivity. Highest productivity. Minimal footprint.
Active Questions & AnswersAsk a Question
There are no current Discussions
Need Equipment Support?
Documents & ManualsView All Documents
Features of 7100 Capillary Electrophoresis System
- Most sensitive CE system on the market
- Replenishment system allows high throughput and unattended operation
- Flexible separation modes including capillary electrochromatography
- Easy maintenance and automated instrument diagnostics
- Plug & play connectivity to all Agilent MS systems
- Easy method setup data analysis
- Regulatory compliance tools
- Comprehensive accessory and consumable offering
- Partner solutions for Laser Induced Fluorescence detection (LIF) and electrochemical detection
General Specifications
Depth | 51 cm |
Height | 59 cm |
Width | 35 cm |
Power Requirements | 100-240 V, 50/60 Hz, max. 300W |
Weight | 35 kg |
Electropheresis Type | Capillary |
Additional Specifications
Pressure System
Programmable with -100 to +100 mbar on inlet
Flushing with 1 bar or with high pressure 2–12 bar
Vial pressurization with high pressure 2–12 bar on inlet and/or outlet
Safety Features
Current leak detection low current limit
Liquid leak sensor
Safety sensors at door and cover disabling high voltage
Vial sensor
Interfaces
LAN, CAN, RS232, remote control, analog in (1V, 20 bit, integrated A/D converter), analog out
Injection Modes
Self correcting injection system with injection from inlet or outlet
Programmable range: Up to 10,000 seconds
Pressure: -100 to +100 mbar
Electrokinetic: –30 to +30 kV
Autosampler/ fraction collector
50-position carousel
All vials are randomly accessible from inlet or outlet end of capillary
Temperature control with external waterbath with vial temperature from 10–40 °C
(non-condensing conditions, minimum waterbath temperature +1 °C)
Replenishment
Satellite station for refilling of inlet or outlet buffer vials with fresh buffer for automatic, continuous operation.
Selectable buffer levelling.
Vials
100 µL (polypropylene or glas) with resealing snap caps
1 mL (polypropylene) with resealing snap caps
2 mL (glas) with resealing snap caps
Capillary cassette
High-speed forced-air cooler with Peltier element
Temperature range: 10 °C below ambient, up to 60 °C (min. 10 °C cassette temperature)
Minimum total capillary length: 33 cm
Capillary compatibility: 365 µm o.d.
Detector
Real time UV-Visible diode-array detector (190–600 nm)
Temperature controlled
Wavelength accuracy: 1 nm
Response time: 0.025 to 10 s
Light source: Prealigned deuterium or high brightness lamp
Signals: Up to eight signals simultaneously, full spectral acquisition with Agilent ChemStation
Sensitivity: 1 µM 4-hydroxy-aceto-phenon injected at 50 mbar*5 sec, 3 x 50 µm bubble cell capillary, signal/noise >6* (50 mM borate buffer pH 9.3, 25 kV)
Baseline noise: <50 µAU (at 2 sec response time)*
Linear dynamic range: 1x104 (3x50 µm bubble cell capillary)*
Raw data channels
Detector signals and spectrum, voltage, current, leak current, power, cassette temperature, pressure, lamp voltage and detector temperature
Diagnostic functions
RFID tag for lamp, early maintenance feedback, supported by Agilent Lab Advisor software with integrated diagnosis test suite
System control
Operating with graphical user interface under Windows XP (SP3)
Time programmable parameters: Time programmable parameters: voltage, current, power, polarity, pressure, inlet and outlet vial, capillary temperature, pre and post-run conditioning with pressure and/or voltage, Replenishment, fraction collection**
Electrophoresis power
Voltage range: Setable 0 to ± 30 kV supply
Current Setable 0–300 µA
Power: Setable 0–6 W
Operation under constant voltage, current or power
Programmable polarity switch
CE specific software
Mobility report, time corrected areas, pI calibration and bio polymer size calibration
Environment
Temperature 5–40 °C
Humidity up to 80 % relative humidity at 31 °C (non-condensing)
* typical value
**upgradeable