Zircar - HOT SPOT 110
A 1700°Celsius Lab Furnace that can simply be plugged into a standard 110 Volt, 20 Amp outlet without the need for 220...
This breakthrough design is made possible by a unique combination of zirconia and alumina insulation, which exploits the hot strength of alumina and low thermal conductivity of zirconia. The zirconia insulation incorporated in the Hot Spot 110 has the lowest thermal conductivity of any commercially available high temperature insulation. The alumina insulation is a newly developed, state of the art, material with exceptional hot strength. The furnace insulation package is a four layer, graded design that ensures the proper heat flow through each layer for maximum life.
Active Questions & AnswersAsk a Question
There are no current Discussions
Lab Furnaces Service ProvidersView All (8)
Documents & Manuals
There are no Documents or Manuals available.
Features of HOT SPOT 110
- Two Models: 110 Volts or 220 Volts * In- Stock Standard Item * Programmable Temperature Controller Holds 2 Programs of up to 8 Steps Each * Space Saving Compact Design * Separate Overtemperature Protection * Low Energy Consumption * Kanthal 1800 Grade Heating Elements * Pre-fired and Pre-programmed * Optional Datalogger Offered * Unique Combination of Zircar Insulations * Fan Cooled Shell & Door Safety Interlock
General Specifications
There are no General Specifications available.
Additional Specifications
Maximum Continuous Use Temperature:
1700°C
Chamber Size:
5″ wide X 4″ high X 5″ deep
Working Size (Ware Space):
3.5″ wide X 4″ high X 3.5″ deep
Overall Size (Door Closed):
20″ wide X 16.5″ deep X 16″ high
Overall Size (Door Open):
20″ wide X 19″ deep X 27″ high
Thermocouple:
Dual Element Type B (Pt6%Rh vs. Pt30%Rh)
Molybdenum Disilicide Heating Elements:
Four Kanthal 1800 grade , 3mm/6mm diameters
Power Supply Requirement for 110 Volt Model:
110V,20A, 60Hz standard US duplex outlet
Power Supply Requirement for 220 Volt Model:
220V, 10A, 50-60 Hz , configurable power cord
Element Current at 1700 C Soak:
40 Amps AC at 5.5Volts
Transient Peak Current Surge on Start Up:
40 Amps AC at 110 Volts
Power Line Consumption at 1700 C Soak:
935 Watts
Series Modals
Zircar - HOT SPOT 110
[+] View Model SpecificationsDepth | 16.6 in |
Height | 16 in |
Internal Depth | 5 in |
Internal Height | 4 in |
Width | 20 in |
Internal Width | 5 in |
Weight | 108 lbs |
Additional Model Specifications | Maximum Continuous Use Temperature: 1700°C Chamber Size: 5″ wide X 4″ high X 5″ deep Working Size (Ware Space): 3.5″ wide X 4″ high X 3.5″ deep Overall Size (Door Closed): 20″ wide X 16.5″ deep X 16″ high Overall Size (Door Open): 20″ wide X 19″ deep X 27″ high Thermocouple: Dual Element Type B (Pt6%Rh vs. Pt30%Rh) Molybdenum Disilicide Heating Elements: Four Kanthal 1800 grade , 3mm/6mm diameters Power Supply Requirement for 110 Volt Model: 110V,20A, 60Hz standard US duplex outlet Power Supply Requirement for 220 Volt Model: 220V, 10A, 50-60 Hz , configurable power cord Element Current at 1700 C Soak: 40 Amps AC at 5.5Volts Transient Peak Current Surge on Start Up: 40 Amps AC at 110 Volts Power Line Consumption at 1700 C Soak: 935 Watts |
Zircar - HOT SPOT 110L
[+] View Model SpecificationsDepth | 16.5 in |
Height | 16 in |
Internal Depth | 5 in |
Internal Height | 4 in |
Width | 20 in |
Internal Width | 6 in |
Power Requirements | 110V |
Weight | 108 |
Additional Model Specifications | Maximum Continuous Use Temperature: 1600°C Minimum Ramp Time to Reach 1600°C Max Temp: 2 hours Chamber Size: 6″ wide X 4″ high X 5″ deep Working Size (Ware Space): 4.5″ wide X 4″ high X 4.5″ deep Overall Size (Door Closed): 20″ wide X 16.5″ deep X 16″ high Overall Size (Door Open): 20″ wide X 19″ deep X 27″ high Weight (Standard Model): 108 pounds Thermocouple: Dual Element Type B (Pt6%Rh vs. Pt30%Rh) Molybdenum Disilicide Heating Elements: 4 Power Supply Requirement for 110 Volt Model: 110V,20A, 60Hz standard US duplex outlet Power Supply Requirement for 220 Volt Model: 220V, 10A, 50-60 Hz , configurable power cord Element Current at 1600 C Soak: ~45Amps AC at 5.5Volts Transient Peak Current Surge on Start Up: 40 Amps AC at 110 Volts Power Line Consumption at 1600 C Soak: ~1320 Watts |