JASCO - FP-6000 series

Manufactured by  JASCO
Follow this Equipment

FP-6000 series of spectrofluorometers

The FP-6000 series of spectrofluorometers meets the demands of both research and routine analysis by combining a highly sensitive and flexible optical system with the 32-bit Windows® based Spectra ManagerTM software platform. The FP-6000 series is equipped with a flexible sample compartment that allows use of a range of prealigned optional sampling accessories to meet many specific application requirements.
Active Questions & AnswersAsk a Question

There are no current Discussions

Need Equipment Support?

Request Support
Documents & Manuals

There are no Documents or Manuals available.

Features of FP-6000 series
Large Throughput Optics The sensitivity is one of most important factor in performance of Fluorescence Spectrophotometer. The FP-6300 is proud of S/N ratio for Raman band of water at 350 nm is greater than 450:1 (SBW: 10 nm on both EX and EM, response: 2 sec., peak-to-peak). It corresponds to greater than 1800:1 at same conditions (SBW: 10 nm on both EX and EM, response: 2 sec., RMS) as competitors. Meeting the Requirements for Biochemistry A trigger switch for starting measurement is available on the main unit as standard, and also enables to control by an operation on the PC. This function is useful to perform Kinetics analysis. System versatility and flexibility The FP-6200 can be used for a wide variety of fluorescence applications. Specific applications may require that specially designed accessories are placed within the instrument. The FP-6200 sample compartment employs pre-aligned mountings which enables various optional accessories to be quickly and easily mounted or demounted without the need for time consuming re-alignment. Horizonal Slit Image The sample illumination optics incorporate an all reflective image rotation optical system to obtain high emission yields. Rotating the slit image of the monochromator formed on the sample cell by 90 deg., the observed volume of the sample illumination is enlarged by the slits length-to-width ratio, resulting in higher emission intensity providing an increase in sensitivity. GLP/GMP Compliance The FP-6300 is designed to keep GLP/GMP compliance using optional validtion tools and program. Compact Design The compact optical bench is housed in a rugged case measuring only 420(W) x 180(D) x 260(H) mm.
General Specifications

There are no General Specifications available.

Looking for New or Used Equipment?

Shop on LabX

Shop on Labx.com