Varian - SpectrAA 220G
Varian SpectrAA 220G Graphite Furnace Atomic Absorption Spectrometer
PC-controlled double beam AA spectrometer. The SpectrAA 110/220 optics feature
four lamp positions with automated wavelength and slit selection, and high intensity deuterium background correction as standard. Lamps are mounted in fixed positions, and a rotating mirror is used to select the operating lamp, eliminating the need for a conventional turret.
For maximum stability in an automated sequence, a software controlled next-lamp warm up facility is provided.
Active Questions & AnswersAsk a Question
Setup of a used system
SpectrAA Support
Need Equipment Support?
Documents & ManualsView All Documents
Features
There are no Features available.
General Specifications
| Depth | 58 cm |
| Height | 59 cm |
| Width | 79 cm |
| Power Requirements | 100 |
| Monochromator | Czerny-Turner |
| Weight | 56 kg |
| Wavelength Range | 185 to 900 nm |
Additional Specifications
MONOCHROMATOR Czerny-Turner with 1,200 lines/mm, holographic quartzovercoated grating, automatic wavelength & slit-size control
Focal length, mm (DIMENSIONS (HXWXD), MAIN) 250
WAVELENGTH RANGE, nm (UV RADIATION INTENSITY) 185-900
RESOLUTION, nm 0.2, 0.5, 1; 0.5 reduced
Scattering,nm/mm 3.2-2.4
DETECTION LIMITS,ppb
As (DETECTION LIMITS,ppb) 0.22
Cu (DETECTION LIMITS,ppb) 0.15
Ni (DETECTION LIMITS,ppb) 0.38
Pb (DETECTION LIMITS,ppb) 0.1
Se (DETECTION LIMITS,ppb) 0.23
OTHER INFORMATION (STAINING POSTS) Windows-based software; multitasking; multielement; software choice of 11 QC tests or full EPA and userdefinable tests; optional software to assist with compliance with FDA 21 CFR Part 11; range of optional accessories, including sample introduction pump
FORMAT (WAVELENGTH, nm) 1 channel, double beam - for more information please see comments.1 channel, double beam, time-shared, rotating-beam combiner
BACKGROUND CORRECT (DETECTION LIMITS,ppb) Fast (2 msec) deuterium arc lamp to 2.3 absorbance units, 185-425 nm, electronic beam balance 1
DISPLAYED INFORMATION (DETECTION LIMITS,ppb) Video displayemission, absorption, peaks, concentration, bracketing standards, standard additions, direct absorbance. With automatic attenuation
Working curve (DETECTION LIMITS,ppb) Blank and 10 standards, 8 algorithms Additional readouts include corrected signals andcalibration graphs.
Memory Unlimited methods, worksheets (includes labels, signal graphics), full export to LIS, spreadsheet 3
Integration, sec (DETECTION LIMITS,ppb) 0.1-30 (1-20 replicates), PH, PA, PrOMT system, integrate repeat 4 Additional memory features include printer and OLE.
Graphics (DETECTION LIMITS,ppb) Color CRT (SVGA) PrOMT is a feature that allows the user to specify the precision required; the instrument measures the sample for the time required to achieve thatprecision.
PRINTER (EXTERNAL BEAM) Optional laser or ink jet, any printer supported by Windows
Microcomputer (DETECTION LIMITS,ppb) Windows 98/ME/NT/ 2000/XP
INTERFACE PROTOCOL (REPORT DISPLAY) PCI-IEEE standard
DIMENSIONS (HXWXD) CM, (IN) (DISPLAY) 59 x 79 x 58 (23.2 x 31 x 23)
WEIGHT, kg (lb) (DISPLAY) 56 (123)
POWER NEEDED 100/120, 220/230/240
Hz (OPERATING) 50/60
HOLLOW-CATHODE LAMPS (DETECTION LIMITS,ppb) 4 lamps, automaticselect mirror, warmup capability, coded, noncoded; optional UltrAA (boosted) lamp