FMS - SuperVap 6
The SuperVap™ system is an automated, standalone, direct-to-vial concentrator that replaces older techniques such as KD, nitrogen blow down and water
The SuperVap concentrator sets new a standard for consistency, speed, and reliability of results for an automated sample evaporation and concentration system. It is ideal for the analysis of pesticides, herbicides, Persistent Organic Pollutants (POPs), PCBs, PAHs, pharmaceutical byproducts, and personal care byproducts as well as many other applications. The programmable SuperVap concentrator is a dry, waterless concentrator that can preheat as well as ramp up to final temperature. It automatically senses when the extract is being delivered to each vessel, starts the blow down and then shuts off the nitrogen when final volume is achieved. The concentrated samples are then automatically transferred directly to a vial, eliminating the errors that occur during manual transfer.
Active Questions & AnswersAsk a Question
There are no current Discussions
Other Service ProvidersView All (9)
Documents & Manuals
There are no Documents or Manuals available.
Features of SuperVap 6
Easy-to-Use The SuperVap concentration system uses a touch screen display for programming, storing, and running methods. Real-time plotting of temperature readings are displayed throughout the process. Simply touch a point on the plot and instantly see the temperature of that point. Reduces Errors The SuperVap system performs the entire evaporation and concentration process, automatically, delivering consistent, reproducibly high recoveries for all analytes. Unattended operation of the sample prep process saves time, reduces labor costs, glassware and solvents.
High Recovery of All Analytes The SuperVap system provides direct-to-vial concentration with automatic endpoint detection and Nitrogen shut off for each vessel
Uses No Water Uses a robust waterless, dry bath with no electronics submerged in water. It easily and inexpensively captures solvents.
Concentrates up to 6 Samples Sample Sizes up to 250 mL.
Compact Size
Minimizes Contamination An integrated HEPA/Carbon filter eliminates outside contamination.
Inexpensive Glassware Economically priced vessels in 500 µL, 1 mL and direct-to-vial.
Fully Automated Automatic endpoint detection, nitrogen shutoff, and alarm for each vessel. Programmable heat ramp and nitrogen settings for precise control of the concentration and evaporation process.
Documentation Every method and run is documented and stored on the SuperVap system for easy retrieval for electronic documentation. A temperature log for each run is also saved and may be downloaded to a PC via a USB port.
Stand Alone or Integrated The SuperVap concentrator can be easily integrated into existing FMS sample preparation systems. Integration allows for PC-based control and automatic solvent exchange.
General Specifications
Depth | 13 in |
Height | 12 in |
Width | 13 in |
Power Requirements | 110 |
Weight | 20 lbs |
Additional Specifications
Gas Requirements:
Nitrogen - 20 PSI minimum
Controller:
Touch Screen
Bath:
Dry