Agilent Technologies - 1200 Series LC Multi-method Solution
Multi-column and solvent switching solution for method development and multi-method applications
Typical applications are in analytical method development, open access systems with different users requiring different separation conditions and for any labs that frequently have to change separation conditions.
- Select of up to 8 columns and up to 26 different solvents by a one-click operation in the user interface of the column compartment and pump.
- Choose between more than 50 LC modules for different pressure ranges,detection requirements, and budgets restrictions.
- Benefit from far beyond 1000 different test conditions for binary, ternary or quaternary gradient separations. No need to disconnect a column or exchange a solvent bottle anymore!
The new Agilent 1290 Infinity Thermostated Column Compartment (TCC) is the heart of an multi-method or method development system. Up to three TCCs can be clustered together – regardless of whether the LC system is based on Agilent 1290 Infinity, 1200 Series RRLC or standard 1200 Series modules. Valves with a reduced pressure range are available for standard pressure systems.
Active Questions & AnswersAsk a Question
Recent Questions & Answers
HPLC Systems Service ProvidersView All (54)
Documents & ManualsView All Documents
Features of 1200 Series LC Multi-method Solution
- Automated and unattend change of separation conditions
- many different system set-up possibilities
- different pressure ranges available - 400, 600, 1200 bar
- many different detectors available
- software support for method screening/development and open access operation
General Specifications
| Detector | variable wavelength, multiple wavelength, diode array, fluorescence, refractive index, evaporative light scattering |
| Maximum Pressure | 1200 bar (1290 Infinity UHPLC) |
Additional Specifications
Column dimensions: Typically 2.1 – 4.6 mm ID, up to 300 mm length
Number of columns: Up to 8
Waste/Bypass: Yes (optional, reduces number of columns)
Number of independent temperature zones: Up to 6
Number of solvents Up to 26
Flow rate: Up to 5 mL/min (binary pump), 10 mL/min (quaternary pump), flow restrictions might apply depending on pump and backpressure
Pressure range: 400 bar (standard 1200 Series LC), 600 bar (1200 Series RRLC), 1200 bar (1290 Infinity UHPLC)
Detection: Agilent 1200 Series variable wavelength, multiple wavelength, diode array, fluorescence, refractive index, evaporative light scattering, or third-party detection through Agilent A/D converter
MS detection: Agilent 6100 Series Quadrupole MS
Software support: Agilent ChemStation B04.01 SP1 or higher, Agilent ChemStation Method Scouting Wizard, Agilent EasyAccess
3rd party Software: ACD/Labs AutoChrom for ChemStation, ChromSword Auto for ChemStation
Videos
1200 Series LC Multi-method Solution Overview