Hach Company - 2100Q Portable Turbidimeter
The Hach 2100Q and 2100Q IS Portable Turbidimeters offer unsurpassed ease of use and accuracy in turbidity measurement.
Active Questions & AnswersAsk a Question
Recent Questions & Answers
Elemental Analyzers Service ProvidersView All (6)
Documents & ManualsView All Documents
Features of 2100Q Portable Turbidimeter
Easy Calibration and Verification
Be confident your measurements are right every time with on-screen assisted calibration and verification. You save time and get accurate results with an easy-to-follow interface that eliminates the need to reference complicated manuals in order to perform routine calibrations. Single-standard RapidCal™ calibration offers a simplified solution for low-level measurements.
Simple Data Transfer
Data transfer with the 2100Q is simple, flexible, and doesn’t require additional software. This feature requires the USB + Power module. All data can be transferred to the module and easily downloaded to your computer with a USB connection, providing superior data integrity and availability. With two different module options, you can customize connectivity and power to meet your specific needs.
Accuracy for Rapidly Settling Samples
The Hach 2100Q Portable Turbidimeter incorporates an innovative Rapidly Settling Turbidity™ (RST) mode to provide accurate, repeatable measurements for difficult-to-measure, rapidly settling samples. An exclusive algorithm that calculates turbidity based on a series of automatic readings eliminates redundant measurements and estimating.
Convenient Data Logging Up to 500 measurements are automatically stored in the instrument for easy access and backup. Stored information includes: date and time, operator ID, reading mode, sample ID, sample number, units, calibration time, calibration status, error messages and the result.
General Specifications
There are no General Specifications available.
Series Modals
Hach Company - 2100Q
[+] View Model SpecificationsDepth | 9 in |
Height | 3 in |
Width | 4.2 in |
Power Requirements | 100 to 240 V |
Weight | 1.17 lbs |
Additional Model Specifications | Accuracy: ± 2 % of reading plus stray light Battery Requirements: 4, AA Certifications: CE certified Compliance certifications: CE/WEEE Data Logger: 500 records Display Size: 240 x 160 pixels Enclosure Rating: IP67 Interface: Optional USB Light Source: tungsten filament lamp Max. operating humidity: 90 Measurement Method: Ratio turbidimetric determination using a primary nephelometric light scatter signal (90°) and transmitted light scatter signal Measurement Modes: Normal (Push to Read), Signal Averaging, Rapidly Settling Turbidity Measuring Range: 0 to 1000 NTU Operating Temperature Range: 0 to 50 °C Repeatability: ± 1 % of reading or 0.01 NTU , whichever is greater Resolution: 0.01 NTU on lowest range Response Time: 6 s in normal reading mode Sample Cell Compatibility: 25 mm x 60 mm round Sample Requirements: 15 mL (0.5 oz) Signal Averaging: Selectable on/off Storage Conditions: -40 °C to 60 °C |
Hach Company - 2100Qis
[+] View Model SpecificationsDepth | 9 in |
Height | 3 in |
Width | 4.2 in |
Power Requirements | 100 to 240 V |
Weight | 1.17 lbs |
Additional Model Specifications | Accuracy: ± 2 % of reading plus stray light of reading plus stray light Battery Requirements: 4, AA Certifications: CE certified Compliance certifications: CE/WEEE Data Logger: 500 records Display Size: 240 x 160 pixels Enclosure Rating: IP67 Interface: Optional USB Light Source: 860 nm LED Max. operating humidity: 90 Measurement Method: Ratio turbidimetric determination using a primary nephelometric light scatter signal and transmitted light scatter signal. Measurement Modes: Normal (Push to Read), Signal Averaging, Rapidly Settling Turbidity Measuring Range: 0 to 1000 FNU Operating Temperature Range: 0 to 50 °C Regulatory: ISO 7027 Repeatability: ± 1 % of reading or 0.01 FNU whichever is greater Resolution: 0.01 FNU on lowest range Response Time: 6 s in normal reading mode Sample Cell Compatibility: 25 mm x 60 mm round Sample Requirements: 15 mL (0.5 oz) Signal Averaging: Selectable on/off Storage Conditions: -40 °C to 60 °C |
Videos
Rugged Portables – 2100Q Portable Turbidimeter