BMG LABTECH - CLARIOstar
Versatile, high-performance microplate reader with monochromators, spectrometer, and filters
Anything is possible. Any wavelength. Any bandwidth. Any assay.
The CLARIOstar® is a multimode microplate reader with Advanced LVF Monochromators, highly sensitive filters, and an ultra-fast spectrometer. It is a modular microplate reader, having up to eight different detection modes, including: Fluorescence Intensity, FRET, Fluorescence Polarization, Luminescence, BRET, UV/Vis Absorbance, Time-Resolved Fluorescence, TR-FRET, and AlphaScreen® /AphaLISA®.[/b]
Detection Modes:
Fluorescence Intensity - including FRET
Fluorescence Polarization / Anisotropy
AlphaScreen® / AlphaLISA®
Luminescence (flash and glow) - including BRET
Time-Resolved Fluorescence - including TR-FRET
UV/Vis Absorbance Spectra
Active Questions & AnswersAsk a Question
There are no current Discussions
Microplate Readers Service ProvidersView All (12)
Documents & Manuals
There are no Documents or Manuals available.
Features of CLARIOstar
Full spectrum UV/Vis absorbance (220 to 1000 nm) * BMG LABTECHs proprietary ultra-fast spectrometer (<1 sec/well) * AlphaScreen®/AlphaLISA® assays are performed with a high energy Laser * Kinetic and cell-based assays can be initiated with reagent injectors * An integrated fluorophore library
Advanced LVF Monochromator & Filter Selector System Perfect for measuring and developing fluorescence assays, the CLARIOstar has an advanced monochromator for flexibility that can be used in combination with filters for greater sensitivity. The advanced monochromators, having continually adjustable wavelengths (320 to 850 nm) and bandwidths (8 to 100 nm) for excitation and emission, have significantly increased performance over conventional monochromators.
Description of Technology BMG's advanced monochromator system consists of two Linear Variable Filter (LVF) Monochromators & Filter Selectors, one for excitation and one for emission. In addition, a Linear Variable Dichroic Mirror (LVDM) slide is used to separate the excitation from the emission light. The LVF Monochromator consists of a Linear Variable Long Pass (LVLP) slide and a Linear Variable Short Pass (LVSP) slide. The LVLP forms the rising edge while the LVSP forms the falling edge of a bandpass filter. By moving the LVLP and the LVSP slides relative to each other, the system creates a filter with a distinct variable peak wavelength and bandwidth. The high transmission and the outstanding blocking of stray light give the CLARIOstar s monochromator system filter-like performance. In addition, the slides can hold fixed filters, polarizers, and fixed dichroic mirrors for special applications like FP, TR-FRET or Alpha Technology.
General Specifications
Depth | 51 cm |
Shaking | 1 |
Height | 40 cm |
Detection Mode | Multi-label |
Width | 45 cm |
Shaking Pattern | Linear, orbital, and double-orbital |
Weight | 32 kg |
Microplate Size | 1536-well |
Software | External |
Temperature Control | 1 |
Additional Specifications
Detection Modes
- Fluorescence Intensity
- FRET
- Fluorescence Polarization
- AlphaScreen®/AlphaLISA®
- Luminescence
- BRET
- Time-Resolved Fluorescence - including TR-FRET
- UV/Vis Absorbance