TurboVap® II increases the capacity and sample throughput in laboratories, eliminates concentration bottlenecks and maintains quality and lower costs. This instrument has 6 sample positions and enables the user to evaporate to solid state or concentrate into a fixed end-point volume. The small footprint of TurboVap® II makes it the ideal choice in today\'s laboratories. It takes up only a fraction of the bench space used by conventional rotary evaporators and can even be used outside a fume cupboard by using the integral vent tube.
Active Questions & AnswersAsk a Question
Recent Questions & Answers
Asked byTPhillips
Vortex Service ProvidersView All (9)
Documents & Manuals
There are no Documents or Manuals available.
Features of TurboVap II
Units may be configured to accommodate either 50 mL or 200 mL glassware with either 0.5 mL or 1.0 mL endpoint stems. TurboVap® II Evaporation System efficiently concentrates samples prior to analysis by LC/MS or other analytical instruments. Optical sensors automatically stop gas flow when evaporation has reached its end-point, thereby eliminating the risk of drying and loss of volatile compounds. TurboVap II is suitable for evaporation of large volumes after liquid-liquid extractions. TurboVap II is available in a Dionex ASE compatible setup which accommodate the use of six 40 mL stemmed and graduated Dionex ASE tubes. Upgrade kits are also available for converting your old TurboVap II.
- Proven equivalency with EPA methods * Patented vortex shearing technology * Patented sensor endpoint detection - no monitoring required * Unattended operation for 1–6 samples * Controlled water bath is adjustable from ambient to 90°C * Operators are free to perform other tasks while evaporation is running * User friendly displays and d agnostics * Convenient bench top size—no hood space required
General Specifications
Depth | 12 in |
Height | 12 in |
Width | 21.2 in |
Power Requirements | 100/120VAC |
Weight | 18.4 kg |
Evaporator Type | Vortex |
Additional Specifications
Fuses:
100/120VAC model 200/220 VAC model 1 ea 10A, Slow, 250V 2 ea 5A,
Technology:
Gas vortex shearing evaporation with sensor endpoint detection.
Number of samples:
1-6
Timer range:
1 to 99 min. or 0.1 to 9.9 hrs.
Max. sample volume:
200 mL
Final endpoint volumes:
0.5 or 1 mL
Water bath capacity:
6.4 L of distilled water
Water bath temp.:
Ambient to 90 °C (Upper temperature with sensors is 60 ºC)
Gas supply requirements :
Minimum inlet pressure 30 psi, 2.1 bar Maximum inlet pressure 80
Gas consumption:
At 11 psi: 0.08 cfm/nozzle or 2.3 L/min/nozzle
Exhaust :
25 CFM blower with 5.1 cm (2\") venting exhaust (tube supplied)
Certifications:
2006/95/EC Low Voltage Directive 2004/108/EC EMC Directive 93/68