Tecan - AC Extraction Plate

Manufactured by  Tecan
Follow this Equipment

Sample Preparation for LC-MS Made Easy

The Tecan AC Extraction Plate with TICE™ (Tecan Immobilized Coating Extraction) technology revolutionizes your sample preparation routine. A simple pipette and shake sequence, with no filtration, centrifugation or solvent evaporation, is all that is required. The AC Extraction Plate is easily integrated into automated processes, making it a perfect match with Tecan’s Freedom EVO® liquid handling platform.   
   
The AC Extraction Plate is an ANSI/SLAS (formerly known as ANSI/SBS) standard, 96­well, deep-well microplate, with each well having a proprietary TICE™ coating. The product is supplied with:   
   
AC Extraction Plate for 96 tests in a protective aluminum inner packaging   
Certificate of Analysis   
Instructions for Use
Active Questions & AnswersAsk a Question

There are no current Discussions

Liquid Handling Service ProvidersView All (10)

Request Support
Documents & Manuals

There are no Documents or Manuals available.

Features of AC Extraction Plate
Cost-effective – Simple pipette and shake workflow, without labor intensive centrifugation, filtration and solvent evaporation steps.        Convenient and fast – Just unpack and start, no conditioning or other preparations needed.        Highly reproducible – Pipette and shake routines are easily standardized and automated on a liquid handling platform, eliminating random errors and increasing consistency of results.
General Specifications
Depth 85.5 mm
Height27.1 mm
Width 127.8 mm
Additional Specifications

AC Extraction Plate:   
96-wells with TICE coating, 1 plate per unit   
Number of tests:   
96 tests   
Max. liquid volume:   
500 Μl   
Chemical resistance:   
Known compatible solvents: Methanol, Acetonitrile, Ethanol, Isopropanol, 2% Acetic Acid, 2% Formic Acid, 2% Ammonium Hydroxide, Ammonium Acetate.   
Known incompatible solvents: Aromatic hydrocarbons, Esters, Ketones and concentrated Acids.    
Operational conditions:   
Standard laboratory range which is 15°C to 32°C (59°F to 90°F). The relative operating humidity must be between 30% to 80% (non-condensing).   
Storage:   
15°C to 32°C (59°F to 90°F), must be stored dry and protected against direct solar radiation.   
Tested pH range:   
Aqueous solutions with a pH range of 2 to 10.   
Expiration date:   
The AC Extraction Plate can be used for up to 6 months from date of manufacture when properly stored (15°C to 32°C), but only until the expiration date as indicated on the primary packaging label.