METTLER TOLEDO - E4 XLS Adjustable Spacers
Manufactured by METTLER TOLEDO
Quickly Move Samples between Formats
For high throughput work involving multiple formats, nothing beats Rainin’s E4 XLS Adjustable Spacer multichannel pipette for speed and flexibility. Simple to use and loaded with features, the E4 XLS enables you to quickly transfer liquids from one format to another. Its speed, ease and legendary accuracy make it ideal for genomic, proteomic and cell culture applications.
Models
EA8-50XLS 8-channel adjustable 5-50 Μl
EA8-300XLS 8-channel adjustable 20–300 Μl
EA8-1200XLS 8-channel adjustable 100–1200 Μl
EA6-300XLS 6-channel adjustable 20–300 Μl
EA6-1200XLS 6-channel adjustable 100–1200 Μl
Models
EA8-50XLS 8-channel adjustable 5-50 Μl
EA8-300XLS 8-channel adjustable 20–300 Μl
EA8-1200XLS 8-channel adjustable 100–1200 Μl
EA6-300XLS 6-channel adjustable 20–300 Μl
EA6-1200XLS 6-channel adjustable 100–1200 Μl
Active Questions & AnswersAsk a Question
There are no current Discussions
Pipettes Service ProvidersView All (10)
Documents & ManualsView All Documents
Features of E4 XLS Adjustable Spacers
Different formats? Not a problem!
For high throughput work involving multiple formats, nothing beats Rainin’s E4 XLS Adjustable Spacer multichannel pipette for speed and flexibility. Simple to use and loaded with features, the E4 XLS enables you to quickly transfer liquids from one format to another. Its speed, ease and legendary accuracy make it ideal for genomic, proteomic and cell culture applications.
Eliminate “Speed Bumps”
Don’t let changing sample formats slow you down. Set the nozzle spacing between 9 and 14 mm (8 channel) or 9 and 19 mm (6 channel) and quickly move samples between different formats.
Simplify Repetitive Pipetting
Multi-dispense takes the drudgery out of repetitive pipetting by calculating how many aliquots can be dispensed from a single pickup. Autopace simplifies repeat dispensing – click the joystick once and repeat dispense across a plate.
Fast format change
Continuously-variable spacing allows nozzle spacing between 9-14 mm on 8-channel models and 9-19 mm on 6-channel models, suitable for pickup from 96-well plates and dispensing to 24-well plates or tubes, or vice versa. Smooth one-hand adjustment enables on-the-fly changing after aspiration and before dispensing. Spacing marks give a quick visual aid, or set the adjustable detent for repeatable spacing without looking.
Absolutely consistent sample pickup
Patented LTS tip and nozzle design provides exceptionally easy multichannel tip mounting, without using nozzle o-rings. Perfect sealing – first time, every time – without rocking or hand-tightening, resulting in perfectly even sample pickup across all channels. Try it – you’ll be amazed how easy it is to get absolutely consistent sample pickup across all channels.
General Specifications
| Maximum Dispensing Volume | 300 μL |
| Channel(s) | 8 |
| Dispensing Volume Range | 5 to 300 μL |
| Pipette Type | Electronic Air Displacement |
| Pipette Volume Type | Variable |