Quadrex - FUSED SILICA CAPILLARY COLUMNS

Manufactured by  Quadrex
Follow this Equipment

Quadrex fused silica columns are produced with the industry standard polyimide outer coating (390°C maximum temperature) for most GC applications

Quadrex fused silica columns are produced with the industry standard polyimide outer coating (390°C maximum temperature) for most general GC applications. Columns with high temperature polyimide coatings, for applications >400°C, are available upon request.     
     
Each stationary phase used in our coating processes is synthesized and cleaned in-house to insure column to column reproducibility. All Quadrex phases are bonded to the silica substrate and cross-linked. Our stringent QA / QC program governs the production of all in-house phases which results in accurate selectivity, reproducibility, and outstanding thermal stability.     
     
Every Quadrex fused silica capillary column is pre-conditioned, QC tested, and shipped with a clear and easy to read Capillary Column Test Data Sheet. This gives you all of the pertinent information regarding the columns' configuration, test operating conditions, and maximum programmed and isothermal operating temperature limits. Column efficiency, activity and film thickness are easily evaluated using an appropriately designed test mixture. We maintain a computer data base of all column data in order to assure you of column-to-column reproducibility.
Active Questions & AnswersAsk a Question

There are no current Discussions

GC Columns Service ProvidersView All (13)

Request Support
Documents & Manuals

There are no Documents or Manuals available.

Features of FUSED SILICA CAPILLARY COLUMNS

PHASE DESIGNATION / CHEMICAL COMPOSITION      007-1       Dimethylpolysiloxane      007-5       (5% Phenyl)Methylpolysiloxane      007-5MS       Silphenylene Polysiloxane       007-10 / 007-20       (10% & 20% Phenyl)Methylpolysiloxanes      007-502 / 007-608 / 007-624      Cyanopropylphenyl Methylpolysiloxanes      007-1301       (6% Cyanopropylphenyl)Methylpolysiloxane      007-35       (35% Phenyl)Methylpolysiloxane       007-1701       (14% Cyanopropylphenyl)Methylpolysiloxane       007-17       (50% Phenyl)Methylpolysiloxane       007-65HT      (65% Phenyl)Methylpolysiloxane      007-225       (50% Cyanopropylphenyl) Methylpolysiloxane       007-CW / BTR-CW       Polyethylene Glycol (PEG)      007-FFAP       Nitroterephthalic acid-modified Polyethylene Glycol (PEG)      007-23       (78% Cyanopropyl)Methylpolysiloxane      PLT-5A/ PLT-Q / PLT-AL2O3      Molecular Sieve 5A      Porous Divinylbenzene polymer      Alumina/KCL

General Specifications

There are no General Specifications available.

Series Modals

Quadrex - 007-1

[+] View Model Specifications

Quadrex - 007-10

[+] View Model Specifications

Quadrex - 007-1301

[+] View Model Specifications

Quadrex - 007-17

[+] View Model Specifications

Quadrex - 007-1701

[+] View Model Specifications

Quadrex - 007-20

[+] View Model Specifications

Quadrex - 007-225

[+] View Model Specifications

Quadrex - 007-23

[+] View Model Specifications

Quadrex - 007-35

[+] View Model Specifications

Quadrex - 007-5

[+] View Model Specifications

Quadrex - 007-5MS

[+] View Model Specifications

Quadrex - 007-608, 007-624, 007-502

[+] View Model Specifications

Quadrex - 007-65HT

[+] View Model Specifications

Quadrex - 007-CW and BTR-CW

[+] View Model Specifications

Quadrex - 007-FFAP

[+] View Model Specifications

Quadrex - PLT-5A

[+] View Model Specifications

Looking for New or Used Equipment?

Shop on LabX

Shop on Labx.com