Quadrex - FUSED SILICA CAPILLARY COLUMNS
Quadrex fused silica columns are produced with the industry standard polyimide outer coating (390°C maximum temperature) for most GC applications
Each stationary phase used in our coating processes is synthesized and cleaned in-house to insure column to column reproducibility. All Quadrex phases are bonded to the silica substrate and cross-linked. Our stringent QA / QC program governs the production of all in-house phases which results in accurate selectivity, reproducibility, and outstanding thermal stability.
Every Quadrex fused silica capillary column is pre-conditioned, QC tested, and shipped with a clear and easy to read Capillary Column Test Data Sheet. This gives you all of the pertinent information regarding the columns' configuration, test operating conditions, and maximum programmed and isothermal operating temperature limits. Column efficiency, activity and film thickness are easily evaluated using an appropriately designed test mixture. We maintain a computer data base of all column data in order to assure you of column-to-column reproducibility.
Active Questions & AnswersAsk a Question
There are no current Discussions
GC Columns Service ProvidersView All (13)
Documents & Manuals
There are no Documents or Manuals available.
Features of FUSED SILICA CAPILLARY COLUMNS
PHASE DESIGNATION / CHEMICAL COMPOSITION 007-1 Dimethylpolysiloxane 007-5 (5% Phenyl)Methylpolysiloxane 007-5MS Silphenylene Polysiloxane 007-10 / 007-20 (10% & 20% Phenyl)Methylpolysiloxanes 007-502 / 007-608 / 007-624 Cyanopropylphenyl Methylpolysiloxanes 007-1301 (6% Cyanopropylphenyl)Methylpolysiloxane 007-35 (35% Phenyl)Methylpolysiloxane 007-1701 (14% Cyanopropylphenyl)Methylpolysiloxane 007-17 (50% Phenyl)Methylpolysiloxane 007-65HT (65% Phenyl)Methylpolysiloxane 007-225 (50% Cyanopropylphenyl) Methylpolysiloxane 007-CW / BTR-CW Polyethylene Glycol (PEG) 007-FFAP Nitroterephthalic acid-modified Polyethylene Glycol (PEG) 007-23 (78% Cyanopropyl)Methylpolysiloxane PLT-5A/ PLT-Q / PLT-AL2O3 Molecular Sieve 5A Porous Divinylbenzene polymer Alumina/KCL
General Specifications
There are no General Specifications available.
Series Modals
Quadrex - 007-1
[+] View Model SpecificationsMaximum Temperature | 350 °C |
Phase | 007-1 |
Additional Model Specifications | DIMETHYLPOLYSILOXANE Bonded and Crosslinked Non polar Excellent thermal stability Comparable to: SE-30, OV-1, OV-101 Similar phases: DB-1, Rtx -1, HP-1, Ultra-1, SPB-1, CPSil-5CB, AT-1, BP-1, DB-Petro, DB-2887, RTx-PONA, RTx-2887, HP-PONA, Petrocol-DH, Petrocol-2887, CP-SimDist-CB, At-Petro USP Phase Specification: G1, G2 |
Quadrex - 007-10
[+] View Model SpecificationsMaximum Temperature | 350 °C |
Phase | G32 |
Additional Model Specifications | 10% PHENYL METHYLPOLYSILOXANE Bonded and crosslinked Comparable to: OV-3, OV-7 Similar phases: Rtx -20, SPB-20 USP Phase Specification: G32 007-10 and 007-20 Phenyl Methylpolysiloxane columns are available in all standard column I.D.'s and column lengths. |
Quadrex - 007-1301
[+] View Model SpecificationsMaximum Temperature | 320 °C |
Phase | G43 |
Additional Model Specifications | (6% CYANOPROPYLPHENYL) METHYLPOLYSILOXANE Bonded and crosslinked Excellent thermal stability Moderately polar Similar phases: DB-1301, Rtx -1301, HP-1301, SPB-1301 USP Phase Specification: G43 007-1301 (6% Cyanopropylphenyl) Methylpolysiloxane columns are available in all standard column I.D.'s and lengths. |
Quadrex - 007-17
[+] View Model SpecificationsMaximum Temperature | 325 °C |
Phase | G3 |
Additional Model Specifications | (50% PHENYL) METHYLPOLYSILOXANE Bonded and crosslinked Medium polarity Comparable to OV-17 Similar phases: DB-17, Rtx-50, SPB-50, AT-50, HP-17, HP-50+, CPSil-20CB USP Phase Specification: G3 Available in all standard column I.D.'s and lengths. |
Quadrex - 007-1701
[+] View Model SpecificationsMaximum Temperature | 280 °C |
Phase | G46 |
Additional Model Specifications | (14% CYANOPROPYLPHENYL) METHYLPOLYSILOXANE Bonded and crosslinked Moderately polar Comparable to OV-1701 Similar phases: DB-1701, Rtx-1701, SPB-1701, AT-1701, HP-1701, BPX-1701 USP Phase Specification: G46 Available in all standard column I.D.'s and lengths. |
Quadrex - 007-20
[+] View Model SpecificationsMaximum Temperature | 350 °C |
Phase | G32 |
Additional Model Specifications | 20% PHENYL METHYLPOLYSILOXANE Bonded and crosslinked Comparable to: OV-3, OV-7 Similar phases: Rtx -20, SPB-20 USP Phase Specification: G32 007-10 and 007-20 Phenyl Methylpolysiloxane columns are available in all standard column I.D.'s and column lengths. |
Quadrex - 007-225
[+] View Model SpecificationsMaximum Temperature | 240 °C |
Phase | G19 |
Additional Model Specifications | (50% CYANOPROPYLPHENYL) METHYLPOLYSILOXANE Bonded and crosslinked Moderately polar Comparable to OV-225 Similar phases: DB-225, Rtx -225, AT-225, SP-2300, BP-225, CPSil-43CB USP Phase Specification: G19 Available in all standard column I.D.'s and lengths. |
Quadrex - 007-23
[+] View Model SpecificationsMaximum Temperature | 280 °C |
Additional Model Specifications | (78% CYANOPROPYL) METHYLPOLYSILOXANE Bonded and crosslinked Very polar Comparable to Silar 7CP, SP-2310 Similar phases: DB-23, Rtx-2330, BPx-70, SP-2330, AT-Silar, CPSil 88 FAME column 007-23, (78% Cyanopropyl) methylpolysiloxane columns are available in 30M. and 60M. lengths with 0.25µm films only. |
Quadrex - 007-35
[+] View Model SpecificationsMaximum Temperature | 300 °C |
Phase | G42 |
Additional Model Specifications | (35% PHENYL) METHYLPOLYSILOXANE Bonded and crosslinked Excellent thermal stability Moderately polar Comparable to OV-11 Similar phases: DB-35, Rtx-35, SPB-35, AT-35, HP-35, BPX-35 USP Phase Specification: G42 Available in all standard column I.D.'s and lengths. |
Quadrex - 007-5
[+] View Model SpecificationsMaximum Temperature | 350 °C |
Phase | G27 |
Additional Model Specifications | (5% PHENYL) METHYLPOLYSILOXANE Bonded and Crosslinked Non polar Excellent thermal stability Comparable to: SE-52, SE-54, OV-73 Similar phases: DB-5, Rtx -5, HP-5, Ultra-5, SPB-5, CPSil-8CB, AT-5, BP-5 USP Phase Specification: G27 |
Quadrex - 007-5MS
[+] View Model SpecificationsMaximum Temperature | 350 °C |
Phase | 007-5MS |
Additional Model Specifications | SILPHENYLENE POLYSILOXANE greater thermal stability greater resistance to oxygen degradation fast ramping to elevated temperatures to purge the column of residual components improved analysis of trace level compounds less baseline bleed equals less baseline noise, which results in lower detection limits increased column lifetimes reduced contamination of MS sources and other GC detector surfaces "cleaner" mass spectra...mass spectra with fewer extraneous ions enables the analyst to achieve more accurate compound identification and a more efficient library search 007-5MS Silphenylene Polysiloxane columns are available in all standard column I.D.'s and in limited column lengths. |
Quadrex - 007-608, 007-624, 007-502
[+] View Model SpecificationsMaximum Temperature | 325 °C |
Phase | DB-624 |
Additional Model Specifications | CYANOPROPYLPHENYL METHYLPOLYSILOXANES Bonded and crosslinked Specifically designed for volatile organic compound analyses Similar phases: DB-624, DB-1301, Rtx-502, DB-608, VOCOL, RTX-Volatiles, PB-608, Rtx-35, AT-624, BP-624, CPSil-13CB USP Phase Specification: G43 |
Quadrex - 007-65HT
[+] View Model SpecificationsMaximum Temperature | 390 °C |
Additional Model Specifications | (65% PHENYL) METHYLPOLYSILOXANE Bonded and crosslinked Excellent thermal stability Moderately polar Similar phases: Rtx-65HT, TAP-CB Available in all standard column I.D.'s and lengths. |
Quadrex - 007-CW and BTR-CW
[+] View Model SpecificationsMaximum Temperature | 280 °C |
Phase | G16 |
Additional Model Specifications | OXYGEN-RESISTANT BTR-CW POLYETHYLENE GLYCOL (PEG) POLYMER Bonded and crosslinked Moderately polar Comparable to Carbowax 20M™* Similar phases: DB-Wax, Stabilwax, AT-Wax, HP-20M, HP-Innowax, Supelcowax-10, BP-20, CPWax-52CB USP Phase Specification: G16 |
Quadrex - 007-FFAP
[+] View Model SpecificationsMaximum Temperature | 280 °C |
Phase | G25 |
Additional Model Specifications | NITROTEREPHTHALIC ACID MODIFIED POLYETHYLENE GLYCOL (PEG) POLYMER Bonded and crosslinked Moderately polar Comparable to FFAP, OV-351, SP-1000 Similar phases: DB-FFAP, AT-1000, HP-FFAP, Stabilwax DA, BP-21, CPWax-58CB, Nukol, CPWax-58CB USP Phase Specification: G25 007-FFAP, Acid-Modified Polyethylene Glycol (PEG) columns are available in all standard column I.D.'s and lengths. |
Quadrex - PLT-5A
[+] View Model SpecificationsMaximum Temperature | 300 °C |
Additional Model Specifications | PLT-5A, MOLECULAR SIEVE 5Å Reliable permanent gas analysis Rugged layer of molecular sieve Excellent thermal stability to regenerate adsorbent layer Similar column types: GS-Molesieve, Rt-MSieve 5A, AT-Mole Sieve PLT-Q, DIVINYLBENZENE COPOLYMER Similar column types: GS-Q, HP-PLOT-Q, Rtx-Q, CP-PoroPLOT-Q PLT-AL2O3, ALUMINA/KCL Similar column types: HP-PLOT-AL2O3, Rt-Alumina BOND, CP-AL2O3 |