FMS - TRP Total-Rapid-Prep system

Manufactured by  FMS
Follow this Equipment

FMS introduces the first and only "Total Solution" Sample Prep system available that combines three sample prep processes into one economical package

The Total-Rapid-Prep™ system performs complete sample preparation for six GC or GC/MS samples for analysis in a few hours. Solid or semi-solid sample is mixed with drying agent and placed in the extraction cells. The extraction cells are then filled with the solvent(s) of choice. They are pressurized & heated. While the samples are being extracted, the cleanup columns are conditioned. As soon as the extraction cycle is terminated, the extraction columns are depressurized, and flushed with solvent, and then purged with nitrogen. At the moment of the extraction columns depressurization the concentration cycle is started. Solvent exchange (if necessary) is performed for the concentrated sample, and the sample is then transferred to the cleanup columns for purification. As soon as the first fractions start to come off the clean up columns, the concentration cycle starts. The final concentrated fractions are then transferred for GC/MS analysis.
Active Questions & AnswersAsk a Question

There are no current Discussions

Sample Preparation Service ProvidersView All (4)

Request Support
Documents & Manuals

There are no Documents or Manuals available.

Features of TRP Total-Rapid-Prep system
  • Automated, unattended operation
  • Same day results for multiple samples
  • Sample preparation for POP analysis made easy
  • Automates EPA SW846 and 40 CFR 136 methods
  • Electronic documentation and reporting
  • Reduce solvent and glassware usage
  • Dramatic savings in time and resources
  • Low background automated sample prep
  • Wide range of inexpensive extraction cell sizes
  • Wide range of pre-packed disposable clean up columns
  • Disposable Columns used for Dioxins and PCBs, PBDEs analysis:
    • Disposable or reusable extraction filtration end caps
    • Modular and expandable
    • A tool for method development
General Specifications

There are no General Specifications available.

Additional Specifications

Pressurized Liquid Extraction System  
Dimensions: 15" W X 18" D X 35" H  
Weight: 140 lbs  
Flow Rate: 0 - 35 mL/minute  
Electrical Input: 110/220 Volts, 50/60 HZ  
Controller: PC based  
 
PowerPrep MultiColumn Cleanup System  
Dimensions: 15" W x 18" D x 35" H  
Weight: 130 lbs.  
Pump: Piston Displacement  
Flow rate: 0.2 to 15 mL/minute  
Electrical Input: 110/220 Volts, 50/60 HZ  
Controller: PC based  
 
SuperVap Concentrator  
Dimensions: 13" W x 13" D x 12" H  
Weight: 20 lbs.  
Gas Requirements: Nitrogen - 20 PSI minimum  
Electrical Input: 110/220 Volts, 50/60 HZ  
Controller: PC based  
Bath: Dry

Looking for New or Used Equipment?

Shop on LabX

Shop on Labx.com