Harvard Apparatus - Peristaltic Pump Series
Manufactured by Harvard Apparatus
The new Harvard Peristaltic Pump series offers unparalleled accuracy, reproducibility, and ease of use over a broad...
The new Harvard Peristaltic Pump series offers unparalleled accuracy, reproducibility, and ease of use over a broad range of flow rates.
The Harvard Peristaltic Pump consists of a control unit, a motor drive, a tubing cassette and some sample tubing. The pump can deliver solutions over a range of flow rates from 0.001 to 1,500 ml/min depending on the motor drive used. Choose from three interchangeable motor drives. The motor drive modules provide flow over the following ranges:
P-70 drive provides flow rates from 0.001 to 70 ml/min
P-230 drive provides flow rates from 0.001 to 230 ml/min
P-1500 drive provides flow rates from 0.01 to 1,500 ml/min
A complete range of programmable functions allow the pump to be easily adapted to a wide range of dispensing applications. The pump has pre-programmed flow profiles for:
Constant Flow
Flow Ramps
Pulsatile Flow
Concentration Based Fluid Delivery
The Harvard Peristaltic Pump consists of a control unit, a motor drive, a tubing cassette and some sample tubing. The pump can deliver solutions over a range of flow rates from 0.001 to 1,500 ml/min depending on the motor drive used. Choose from three interchangeable motor drives. The motor drive modules provide flow over the following ranges:
A complete range of programmable functions allow the pump to be easily adapted to a wide range of dispensing applications. The pump has pre-programmed flow profiles for:
Active Questions & AnswersAsk a Question
There are no current Discussions
Lab Pumps Service ProvidersView All (3)
Documents & Manuals
There are no Documents or Manuals available.
Features of Peristaltic Pump Series
General Specifications
There are no General Specifications available.
Series Modals
Harvard Apparatus - P-1500
[+] View Model Specifications| Depth | 9.6 cm |
| Height | 20.7 cm |
| Width | 13 cm |
| Power Requirements | 100-250 VAC, 50/60 Hz |
| Weight | 5 kg |
| Additional Model Specifications | Pump Configuration
Remote Number of Channels 1 channels Number of Rollers 4 rollers Protection Rating IP23 Tubing ID Metric 0.8 to 4.8 mm Tubing ID English 0.03 to 0.19 in Max RPM 375 Minimum Flow Rate 0.001 ml/min Maximum Flow Rate 1500 ml/min Reversible Flow yes Accuracy ±1.0% Computer Interface USB Type B Pump to Pump IEEE 1394 TTL Connector 15-pin D-sub Back Pressure 30 psi |
Harvard Apparatus - P-230
[+] View Model Specifications| Depth | 9.6 cm |
| Height | 20.7 cm |
| Width | 13 cm |
| Power Requirements | 100-250 VAC, 50/60 Hz |
| Weight | 5 kg |
| Additional Model Specifications | Pump Configuration
Remote Number of Channels 4 channels Number of Rollers 8 rollers Protection Rating IP23 Tubing ID Metric 0.13 to 3.17 mm Tubing ID English 0.005 to 0.13 in Max RPM 230 Minimum Flow Rate 0.001 ml/min Maximum Flow Rate 230 ml/min Reversible Flow yes Accuracy ±1.0% Computer Interface USB Type B Pump to Pump IEEE 1394 TTL Connector 15-pin D-sub Back Pressure 15 psi |
Harvard Apparatus - P-70
[+] View Model Specifications| Depth | 9.6 cm |
| Height | 20.7 cm |
| Width | 13 cm |
| Power Requirements | 100-250 VAC, 50/60 Hz |
| Weight | 4.7 kg |
| Additional Model Specifications | Pump Configuration
Remote Number of Channels 5 channels Number of Rollers 8 rollers Protection Rating IP23 Tubing ID Metric 0.13 to 2.79 mm Tubing ID English 0.005 to 0.11 in Max RPM 220 Minimum Flow Rate 0.001 ml/min Maximum Flow Rate 70 ml/min Reversible Flow yes Accuracy ±1.0% Computer Interface USB Type B Pump to Pump IEEE 1394 TTL Connector 15-pin D-sub Back Pressure 15 psi |