Malvern Panalytical - MicroCal ITC range
Manufactured by Malvern Panalytical
Determine the binding parameters of biomolecules in a single analysis
MicroCal ITC isothermal titration calorimeters are used to study a wide range of biomolecular interactions. The applications range from drug design to fundamental research such as the understanding and regulation of signal transduction pathways. These systems deliver direct, label free and in-solution measurements of binding affinity and thermodynamic parameters in a single experiment. They have high sensitivity, low sample consumption and options for automation to minimize ‘hands on’ time. A choice of instruments ensures that MicroCal ITC calorimeters meet the varied and demanding requirements of today’s life science laboratories.
Active Questions & AnswersAsk a Question
3Replies
Thermostat instability
Recent Questions & Answers
Updated byMalvern
Need Equipment Support?
Documents & ManualsView All Documents
Features
There are no Features available.
General Specifications
There are no General Specifications available.
Series Modals
Malvern Panalytical - MicroCal Auto-iTC200
[+] View Model SpecificationsDepth | 350 mm |
Height | 770 mm |
Width | 630 mm |
Maximum Temperature | 80 °C |
Power Requirements | 100-240V, 50/60Hz |
Peak Power | 70 W |
Weight | 91 kg |
Additional Model Specifications | Measurement type: Affinity (KD) Measurement type: Enthalpy ?H Measurement type: Entropy ?S Measurement type: Stoichiometry (n) Sample capacity: 384 (four 96 well plates) Sample tray temperature range: 4°C ± 2°C at ambient Sample volume: 370µL Cell volume: 200µL Injection syringe volume: 40µL Injection volume precision: <1% @ 2µL Equilibration time: < 6 min (from 25°C to 5°C) Sample presentation options: 96 well plate Sample capacity: Up to 75 per 24h (SIM) Cell material: Hastelloy Cell: Coin-shaped Noise: 0.2 ncal/s Temperature range: 2°C to 80°C Temperature stability: ± 0.00015°C (at 25°C) Response time: 10s (high feedback) Multiple feedback modes: Yes (passive, high gain, low gain) Operating environment Operating temperature (°C): 10°C to 28°C Humidity: 0% to 70% RH, non condensing |
Malvern Panalytical - MicroCal iTC200
[+] View Model SpecificationsDepth | 350 mm |
Height | 340 mm |
Width | 210 mm |
Maximum Temperature | 80 °C |
Power Requirements | 100-240V, 50/60Hz |
Peak Power | 70 W |
Weight | 9.4 kg |
Additional Model Specifications | Measurement type: Affinity (KD) Measurement type: Enthalpy ?H Measurement type: Entropy ?S Measurement type: Stoichiometry (n) Sample volume: 280µL Cell volume: 200µL Injection syringe volume: 40µL Injection volume precision: <1% @ 2µL Equilibration time: < 6min (from 25°C to 5°C) Sample capacity: 8-12 per 8h day Cell material: Hastelloy Cell: Coin-shaped Noise: 0.2 ncal/s Temperature range: 2°C to 80°C Temperature stability: ± 0.00015°C (at 25°) Response time: 10s (high feedback) Multiple feedback modes: Yes (passive, high gain, low gain) Automated upgrade available: Yes Operating environment Temperature (operating): 10°C to 28°C Humidity: 0% to 70% RH, non condensing |
Malvern Panalytical - MicroCal VP-ITC
[+] View Model SpecificationsDepth | 370 mm |
Height | 440 mm |
Width | 200 mm |
Maximum Temperature | 80 °C |
Power Requirements | 100-240V, 50/60Hz |
Peak Power | 120 W |
Weight | 11.5 kg |
Additional Model Specifications | Measurement type: Affinity (KD) Measurement type: Enthalpy ?H Measurement type: Entropy ?S Measurement type: Stoichiometry (n) Sample volume: 2mL Cell volume: 1400µL Injection syringe volume: 300µL Sample capacity: 4-8 per 8h day Cell material: Hastelloy Cell: Coin-shaped Noise: 0.2 ncal/s Temperature range: 2°C to 80°C Response time: 20s (high feedback) Multiple feedback modes: Yes (passive, high gain, low gain) Dimensions (W, D, H): 150mm x 410mm x 360mm (Controller) Weight: 9 kg (Controller) Operating environment Temperature (operating): 10°C to 28°C Humidity: 0% to 70% RH, non condensing |