A&D Weighing - HR Series
Manufactured by A&D Weighing
Orion Analytical Balance Series
The Orion Series balances provide many remarkable features at affordable prices. These easy-to-use analytical balances are durable, adapt to your environment, and provide great flexibility and resolution.
Active Questions & AnswersAsk a Question
There are no current Discussions
Balances Service ProvidersView All (23)
Documents & ManualsView All Documents
Features of HR Series
- Large Weighing Chamber holds up to a 250mm volumetric flask Wide Angle LCD Display
- Multi-Functional Weighing
- Standard Underhook
- GLP/LIMS/ISO Compliant
- Multi-Functional Weighing: %, Counting, Grams, mg. oz ozt, dwt, ct, mom, GN, t, TL Separate, Clearly Marked Operating Keys Full Range Tare
- Body & frame constructed of extra strong die-cast aluminum alloy
- HR-60 model only is legal-for-trade, Class II
General Specifications
There are no General Specifications available.
Series Modals
A&D Weighing - HR-120
[+] View Model SpecificationsDepth | 12.6 in |
Height | 11.9 in |
Width | 8.4 in |
Power Requirements | 100, 120, 220, 240 VAC (AC Adaptor) 50 Hz/60 Hz. 10 hours continuous operation with rechargeable battery pack |
Balance Type | Analytical Balance |
Weight | 12.5 lbs Approximately |
Additional Model Specifications | Gram: (g) 120x0.0001 (mg)120000x0.1 Decimal Ounce(oz): 4.2x0.000005 Troy Ounce(ozt): 3.8x0.000005 Pennyweight(dwt): 77x0.0001 Carat (ct): 600x0.001 Momme (mom): 32x0.00005 Grain Unit (GN): 1851x0.002 Tola (t): 10x0.00001 Tael (TL): 3.1x0.000005 Percentage Min Div: 0.01%, 0.1% or 1% (auto prompt) Counting Min Weight: 0.1 mg Linearity: ±0.0002 g Repeatability/Std Dev: 0.0001 g Stabilization Time: 3 seconds (typically) Sensitivity Drift (10°C-30°C): ±2ppm/°C (when automatic self calibration is not used) Display Refresh: 5 times per second/10 times per second Pan Size: Ø 85 mm/3.3 inches Physical Dimensions: (mm): 213(W) x 319(D) x 301(H) Breeze Break Dimensions: (mm): 180(W) x 192(D) x 200 H) (in): 7.1(W) x 7.5(D) x 7.9(H) Operating Temperature: 5C to 40C (41 F to 104 F), 85% RH or less (no condensation) Standard Accessories: Manual, AC Adapter, Protective Cover Ext. Cal. Mass (optional): 100 g |
A&D Weighing - HR-200
[+] View Model SpecificationsDepth | 12.6 in |
Height | 11.9 in |
Width | 8.4 in |
Power Requirements | 100, 120, 220, 240 VAC (AC Adaptor) 50 Hz/60 Hz. 10 hours continuous operation with rechargeable battery pack |
Balance Type | Analytical Balance |
Weight | 12.5 lbs Approximately |
Additional Model Specifications | Gram: (g) 210x0.0001 (mg)210000x0.1 Decimal Ounce(oz): 7.4x0.000005 Troy Ounce(ozt): 6.7x0.000005 Pennyweight(dwt): 38x0.0001 Carat (ct): 1050x0.001 Momme (mom): 56x0.00005 Grain Unit (GN): 3240x0.002 Tola (t): 18x0.00001 Tael (TL): 5.5x0.000005 Percentage Min Div: 0.01%, 0.1% or 1% (auto prompt) Counting Min Weight: 0.1 mg Sensitivity Drift (10°C-30°C): ±2ppm/°C (when automatic self calibration is not used) Display Refresh: 5 times per second/10 times per second Pan Size: Ø 85 mm/3.3 inches Physical Dimensions: (mm): 213(W) x 319(D) x 301(H) Breeze Break Dimensions: (mm): 180(W) x 192(D) x 200 H) (in): 7.1(W) x 7.5(D) x 7.9(H) Operating Temperature: 5C to 40C (41 F to 104 F), 85% RH or less (no condensation) Standard Accessories: Manual, AC Adapter, Protective Cover Ext. Cal. Mass (optional): 200 g |
A&D Weighing - HR-202i
[+] View Model SpecificationsDepth | 17.4 in |
Height | 12.24 in |
Width | 8.54 in |
Power Requirements | 100, 120, 220, 240 VAC (AC Adapter). 50 Hz/60 Hz, 11 VA |
Balance Type | Analytical Balance |
Weight | 17.6 lbs Approximately |
Additional Model Specifications | Gram: (g) 220x0.0001/51x0.00001 (mg)220000x0.1/51000x0.01 Decimal Ounce(oz): 7.76x0.00001/1.8x0.000001 Troy Ounce(ozt): 7.07x0.00001/1.64x0.000001 Pennyweight(dwt): 141.5x0.0001/32.8x0.00001 Carat (ct): 1100x0.001/255x0.0001 Momme (mom): 58.7x0.0001/13.6x0.00001 Grain Unit (GN): 3395x0.002/787x0.0002 Tola (t): 18.8x0.00001/4.37x0.000001 Tael (TL): 5.87x0.00001/1.36x0.000001 Percentage Min Div: 0.01%, 0.1% or 1% (auto prompt) Counting Min Weight: 0.1 mg Linearity: 0.0001/0.00002 g Repeatability/Std Dev: ±0.0002/±0.00003 g Stabilization Time: Approx. 3.5/8 seconds Sensitivity Drift (10°C-30°C): ±2ppm/°C (when automatic self calibration is not used) Display Refresh: 5 times per second/10 times per second Pan Size: Ø 90 mm/3.6 inches Physical Dimensions: (mm): 217(W) x 442(D) x 316(H) Breeze Break Dimensions: (mm): 164(W) x 148.5(D) x 251(H) (in): 6.45(W) x 5.84(D) x 9.88(H) Operating Temperature: 5C to 40C (41 F to 104 F), 85% RH or less (no condensation) Standard Accessories: WinCT in CD-ROM, Manual, AC Adapter Ext. Cal. Mass (optional): 200 g/100 g/50 g/20 g |
A&D Weighing - HR-300i
[+] View Model SpecificationsDepth | 17.4 in |
Height | 12.24 in |
Width | 8.54 in |
Power Requirements | 100, 120, 220, 240 VAC (AC Adapter). 50 Hz/60 Hz, 11 VA |
Weight | 17.6 lbs Approximately |
Additional Model Specifications | Gram: (g) 320x0.0001 (mg)320000x0.1 Decimal Ounce(oz): 11.29x0.00001 Troy Ounce(ozt): 10.3x0.00001 Pennyweight(dwt): 199x0.0001 Carat (ct): 1550x0.001 Momme (mom): 82x0.0001 Grain Unit (GN): 4784x0.002 Tola (t): 26x0.00001 Tael (TL): 8.2x0.00001 Percentage Min Div: 0.01%, 0.1% or 1% (auto prompt) Counting Min Weight: 0.1 mg Linearity: 0.0002 mg Repeatability/Std Dev: ±0.0003 mg Stabilization Time: Approx. 3.5 seconds Sensitivity Drift (10°C-30°C): ±2ppm/°C (when automatic self calibration is not used) Display Refresh: 5 times per second/10 times per second Pan Size: Ø 90 mm/3.6 inches Physical Dimensions: (mm): 217(W) x 442(D) x 316(H) Breeze Break Dimensions: (mm): 164(W) x 148.5(D) x 251(H) (in): 6.45(W) x 5.84(D) x 9.88(H) Operating Temperature: 5C to 40C (41 F to 104 F), 85% RH or less (no condensation) Standard Accessories: WinCT in CD-ROM, Manual, AC Adapter Ext. Cal. Mass (optional): 300 g/200 g/100 g |
A&D Weighing - HR-60
[+] View Model SpecificationsDepth | 12.6 in |
Height | 11.9 in |
Width | 8.4 in |
Power Requirements | 100, 120, 220, 240 VAC (AC Adaptor) 50 Hz/60 Hz. 10 hours continuous operation with rechargeable battery pack |
Weight | 12.5 lbs Approximately |
Additional Model Specifications | Gram: (g) 60x0.0001 (mg)60000x0.1 Decimal Ounce(oz): 2.1x0.000005 Troy Ounce(ozt): 1.9x0.000005 Pennyweight(dwt): 38x0.0001 Carat (ct): 300x0.001 Momme (mom): 16x0.00005 Grain Unit (GN): 925x0.002 Tola (t): 5x0.00001 Tael (TL): 1.5x0.000005 Percentage Min Div: 0.01%, 0.1% or 1% (auto prompt) Counting Min Weight: 0.1 mg Sensitivity Drift (10°C-30°C): ±2ppm/°C (when automatic self calibration is not used) Display Refresh: 5 times per second/10 times per second Pan Size: Ø 85 mm/3.3 inches Physical Dimensions: (mm): 213(W) x 319(D) x 301(H) Breeze Break Dimensions: (mm): 180(W) x 192(D) x 200 H) (in): 7.1(W) x 7.5(D) x 7.9(H) Operating Temperature: 5C to 40C (41 F to 104 F), 85% RH or less (no condensation) Standard Accessories: Manual, AC Adapter, Protective Cover Ext. Cal. Mass (optional): 50 g |