NuAire - AutoFlow NU-4750
Water Jacket CO2 Incubator
Active Questions & AnswersAsk a Question
CO2 Fault
CO2 Incubator Service ProvidersView All (28)
Documents & ManualsView All Documents
Features of AutoFlow NU-4750
Closed Loop HEPA Filtration
Limits the need for moving parts minimizing vibration. An air pump injects filtered air into the work chamber. The air recirculates through sensor checkpoints before it is re-injected into the work chamber passing through a 99.99% HEPA filter. This system slows air movement to one chamber air change every 30 minutes. The decelerated air movement ensures ISO class 5 air conditions to minimize cell desiccation by airflow.
NICE Electronics
NuAire Incubator Control Electronics (NICE) is a state-of-the-art microcomputer based control system specifically designed to service the precise control requirements of the chambers environment, providing optimum programmable conditions for culture growth.
Constant Contamination Control
A unique HEPA filtration system filters fresh air into the pump, CO2 gas from tanks or house systems, IR CO2 sensor sample air returning to the change, air between air pump and inner chamber, while continuously filtering the internal chamber to create ISO Class 5 air quality.
Cleanroom within a Cleanroom
Interior chamber is constantly maintained at positive pressure similar to an ISO Class 5 Cleanroom
Sensitivity and Accuracy of Gas Control
Infrared (IR) CO2 sensor provides stable outputs requiring less calibrations.
Precision of Electronic Microprocessor Controls
A programmable microcontroller samples input sensors, sets control outputs, and makes necessary corrections to the chamber environments resulting in quick and responsive recovery times.
Reliability and Protection of Automated and Redundant Back-up Systems
Dual temperature sensor probes, solid-state analyzers, HEPA filtration systems, and status alarms create a dependable, long lasting scientific instrument.
Critical Cleaning Components
Coved corners prevent contaminants from becoming trapped in the chamber. Removable shelves, brackets, and gasket make cleaning simple by cleaning around them or placing them in the autoclave.
Homogeneous Temperature
All 6 sides of the chambers walls feature heating elements surrounded by R5 insulation to provide optimum temperature uniformity in the work chamber.
- 100% Stainless Steel Interior
- 4 Removable Stainless Steel Shelves
- 20 Gallon (75.7 L) Water Jacket
- Remote Alarm Output Contacts
- CO2 Sample Port
- Adjustable Leg Levelers
- Access Port
- Water Pan
Optional Features
- Internal Tank Switch
- RS-232 Communications Interface
- Multi-Signal Analog Outputs
- Additional Shelves
- Cooling Coil
- 4 Segmented Inner Lexan Doors
- Right Door Swing
- Humidity Display
General Specifications
CO2 Incubator Type | Water Jacketed |
Depth | 25.5 in |
Temperature Uniformity | 0.2 °C |
Height | 34 in |
Internal Depth | 21 in |
Internal Height | 21.5 in |
Width | 31 in |
Internal Width | 25.5 in |
Chamber Volume | 188 L |
CO2 Range | 0.1 to 20 % |
Weight | 222 lbs |
O2 Accuracy | 0 |
CO2 Accuracy | 0.1 % |
Temperature Accuracy | 0.125 |