Fungilab - Pro Series
Professional and Accurate viscosity results. Customize your...
Active Questions & AnswersAsk a Question
There are no current Discussions
Need Equipment Support?
Documents & Manuals
There are no Documents or Manuals available.
Features of Pro Series
Languages options: English / French / German / Catalan / Spanish / Italian / Japanese / Polish / Dutch / Portuguese
Program features:
- Time to torque
- Time to stop
- 10 working memories
- Customizable option (Speeds)
- Programmable: Multistep/Ramp
- Unit Converter (IS or CGS)
USB interface: Faster transfer data to the computer
Auto-test: It checks the internal function in order to make the unit ready to use
ViscOsity readings:
- Absolute viscosity (cP or mPa·s)
- Apparent viscosity (cP or mPa·s)
- Kinematic viscosity (cSt, mm2/sec)
(Density introduced by the user)
10 working memories: Set up the unit and get it ready to be used every day choosing the memory you need
Data displayed:
- Selected Speed
- Selected Spindle
- Viscosity readings (cP or mPa·s or cSt)
- Percentage of Full Scale Range (%)
- Sample Temperature (oC or oF)
- Shear rate (with coaxial spindles) (s-1)
- Shear Stress (with coaxial spindles) (N/m2)
- Density (introduced by the user) (g/cm3)
Universal adapter: All accessories such as Brookfield (Optional)
Datalogger software included: USB allows data transfer to a Excel format
Spindles: AISI 316 stainless steel spindles, easily identified by number and letter when changed according to range of viscosity.
These are the standards our units follow:
- BS: 6075, 5350
- ISO: 2555, 1652
- ASTM: 115, 789, 1076, 1084, 1286, 1417, 1439, 1638, 1824, 2196, 2336, 2364, 2393, 2556, 2669, 2849, 2983, 2994, 3232, 3236, 3716
General Specifications
There are no General Specifications available.
Series Modals
Fungilab - PRO H
[+] View Model SpecificationsTemperature Range | 0 to 100 °C |
Viscometer Type | Rotational |
Power Requirements | 100-240 VAC, 50/60 Hz |
Maximum Viscosity | 106000000 cP |
Viscosity Range | 200 to 106000000 cP |
Part Number | VL300001 |
Speed Range | 0.01 to 200 rpm |
Repeatability | 0.2% |
Additional Model Specifications | Precision: ± 1% of full scale Resolution: With low viscosity adapter: 0.01 For lower than 10.000 viscosity cP: 0.1 For viscosity equal to or above 10.000 cP: 1 Repeatability: 0.2% Thermometer features Resolution: 0.1ºC / 0.1722ºF Precision: +/- 0.1 ºC Type of probe: PT100 Supplied at: 100-240 VAC, 50/60 Hz Software: Fungilab Data Boss The Fungilab Data Boss software complies the FDA 21CFR PART 11 regulation Measuring Range (cP): 200 - 106.000.000 Number of speeds: 54 |
Fungilab - PRO L
[+] View Model SpecificationsTemperature Range | 0 to 100 °C |
Viscometer Type | Rotational |
Power Requirements | 100-240 VAC, 50/60 Hz |
Maximum Viscosity | 6000000 cP |
Viscosity Range | 1 to 6000000 cP |
Part Number | VL300003 |
Speed Range | 0.01 to 200 rpm |
Repeatability | 0.2% |
Additional Model Specifications | Precision: ± 1% of full scale Resolution: With low viscosity adapter: 0.01 For lower than 10.000 viscosity cP: 0.1 For viscosity equal to or above 10.000 cP: 1 Repeatability: 0.2% Thermometer features Resolution: 0.1ºC / 0.1722ºF Precision: +/- 0.1 ºC Type of probe: PT100 Supplied at: 100-240 VAC, 50/60 Hz Software: Fungilab Data Boss The Fungilab Data Boss software complies the FDA 21CFR PART 11 regulation Measuring Range (cP): *1 - 6.000.000 Number of speeds: 54 |
Fungilab - PRO R
[+] View Model SpecificationsTemperature Range | 0 to 100 °C |
Viscometer Type | Rotational |
Power Requirements | 100-240 VAC, 50/60 Hz |
Maximum Viscosity | 40000000 cP |
Viscosity Range | 100 to 40000000 cP |
Part Number | VL300002 |
Speed Range | 0.01 to 200 rpm |
Repeatability | 0.2% |
Additional Model Specifications | Precision: ± 1% of full scale Resolution: With low viscosity adapter: 0.01 For lower than 10.000 viscosity cP: 0.1 For viscosity equal to or above 10.000 cP: 1 Repeatability: 0.2% Thermometer features Resolution: 0.1ºC / 0.1722ºF Precision: +/- 0.1 ºC Type of probe: PT100 Supplied at: 100-240 VAC, 50/60 Hz Software: Fungilab Data Boss The Fungilab Data Boss software complies the FDA 21CFR PART 11 regulation Measuring Range (cP): 100 - 40.000.000 Number of speeds: 54 |