Wyatt Technology - Eclipse DUALTEC

Manufactured by  Wyatt Technology
Follow this Equipment

A new level of sensitivity, productivity, and flexibility for separating proteins, biopolymers, polymers, and nanoparticles.

The Eclipse™ DualTec solves the most difficult separation, fractionation and sizing tasks for macromolecules, nanoparticles and colloids by means of field-flow fractionation. It offers a routine method to complement size exclusion chromatography (SEC), with a separation range of 1 nm to 1000 nm. Combined with a Wyatt DAWN® or miniDAWN™ MALS detector and Optilab® T-rEX™ refractive index detector, the Eclipse DualTec offers a uniquely versatile solution providing characterization of absolute molar mass and size as well as conformation and conjugation. 
 
The DualTec supports both Hollow-Fiber Flow-FFF (HF5) and Asymmetric Flow-FFF (AF4) techniques, as well as SEC. Even better, it supports software switching between two separation channels, e.g. SEC and AF4, or SEC and HF5, enhancing rather than simply replacing standard analytical capabilities. The entire system is based on industry-standard liquid chromatography components. 
 
AF4 utilizes an open separation channel with no stationary phase and very little surface area, and therefore generates almost no shear that can degrade sensitive samples. Since very little surface area is involved, adverse interactions between the sample and surfaces are minimized relative to sizing columns. Its resolution is similar to that of analytical ultracentifugation, but it surpasses even this benchmark-sizing tool when one considers its flexibility, speed, and ease of use. 
 
HF5 is similar to AF4 except the separation channel is far smaller, resulting in fast, nL-scale separations over a similar size range, outperforming UHPLC-SEC in many regards. 
 
The Eclipse AF4 integrates seamlessly with various market-leading HPLC packages, such as Agilent, Thermo Scientific and Shimadzu, utilizing high-quality pumps, degassers, autosamplers and UV detectors while replacing just the column with an AF4 or HF5 channel. The chassis can be ordered in three versions: for aqueous solvents (biocompatible), for organic solvents and in a metal-free version.
Active Questions & AnswersAsk a Question

There are no current Discussions

Particle Size Analyzers Service ProvidersView All (2)

Request Support
Documents & Manuals

There are no Documents or Manuals available.

Features

There are no Features available.

General Specifications
Depth 64 cm
Height25 cm
Width 36 cm

Looking for New or Used Equipment?

Shop on LabX

Shop on Labx.com