Ultra Fine-Tuned™ technology is what sets the Synergy Mx Multi-Mode Reader apart. Its quadruple monochromator system selects wavelengths with a repeatability of plus or minus 0.2 nm. Its top optical head can focus up and down on the samples with a 100 µm resolution. Four slits on the excitation and emission side provide a choice of 16 bandpass combinations for every wavelength pair. Its advanced 4-Zone™ temperature control system incubates up to 65°C with a precision of ± 0.5°C at 37°C. These unique features and BioTek’s exclusive focus on microplate instrumentation and software make the Synergy Mx the most precise, sensitive and flexible multi-mode microplate reader available today for life-science research applications.
Active Questions & AnswersAsk a Question
1Replies
query about TRF assay
Recent Questions & Answers
Updated byBioTek Instruments
Microplate Readers Service ProvidersView All (12)
Documents & Manuals
There are no Documents or Manuals available.
Features of Synergy Mx
- Fully monochromator-based with quadruple grating architecture for Ultra Fine-Tuned performance.
- Compatible with Take3 Multi-Volume Plate: sixteen 2 µL microspots for low volume DNA/RNA 260 nm measurements. Saves precious samples, very fast and simple process.
- High performance fluorescence (top and bottom), absorbance and dedicated luminescence detection systems accommodate all life-science research microplate applications.
- Variable bandpass selection adds flexibility in fluorescence mode.
- Automated Z-height adjustment accommodates variable microplate heights and liquid levels with 100 µm resolution.
- Cuvette port to measure standard 1-cm path cuvettes if only a few samples need to be run, or to compare data with a standard cuvette spectrophotometer.
- Modular architecture allows purchase of required modes with the ability to upgrade later.
- Optional dual-reagent dispenser can be used for assays requiring precise timing such as ion channel assays or luminescent flash ATP assays.
General Specifications
There are no General Specifications available.
Additional Specifications
Injection Volume Range: 5 - 1000 µL
Shaking: Yes
Software: Gen5™ Included. Control through USB or serial port.
Automation: Yes
Series Modals
BioTek - Absorbance
[+] View Model SpecificationsBandwidth | 2 nm (230-285 nm), 4 nm (>285 nm) |
Depth | 20.9 in |
Height | 15 in |
Detection Mode | Multi-label |
Width | 17 in |
Detection Method | Fluorescence, UV-Visible Absorbance, Luminescence, Time-Resolved Fluorescence (secondary mode) |
Power Requirements | 250 Watts max. |
Sample Formats | 1- to 384-well plates and PCR plates Compatible with Take3 Multi-Volume Plate with 2 µL microspots |
Lighting | High Energy Xenon Flash |
Weight | 70 lbs |
Read Method | End-point, kinetic, spectral scanning, well-area scanning |
Wavelength Range | 230 to 999 nm |
Scanning Speed | 96 wells: 11 seconds, 384 wells: 22 seconds |
Wavelength Selection | Double Monochromator |
Additional Model Specifications | Shaking: Yes Software: Gen5™ Included. Control through USB or serial port. Automation: Yes Absorbance Dynamic range: 0 - 4.0 OD Resolution: 0.0001 OD Pathlength correction: Yes Monochromator wavelength accuracy: +/- 2 nm Monochromator wavelength repeatability: +/- 0.2 nm OD accuracy: < 1% at 2.0 OD typical OD linearity: < 1% from 0 to 3.0 OD typical OD repeatability: < 0.5% at 2.0 OD typical Reagent Dispensers Number: 2 syringe pumps Dispense volume: 5 - 1000 µL in 1 µL increment Dead volume: 1.1 mL, 100 µL with back flush Regulatory: For in vitro diagnostic use. All BioTek microplate instrumentation is CE and ETL marked. For details on approvals and standards compliance, please contact BioTek. |
BioTek - Fluorescence Intensity
[+] View Model SpecificationsBandwidth | Variable: 9, 13.5, 17, 20 nm |
Depth | 20.9 in |
Detector | Dedicated red shifted PMT |
Height | 15 in |
Detection Mode | Multi-label |
Width | 17 in |
Detection Method | Fluorescence, UV-Visible Absorbance, Luminescence, Time-Resolved Fluorescence (secondary mode) |
Power Requirements | 250 Watts max. |
Sample Formats | 1- to 384-well plates and PCR plates Compatible with Take3 Multi-Volume Plate with 2 µL microspots |
Lighting | High Energy Xenon Flash |
Weight | 70 lbs |
Read Method | End-point, kinetic, spectral scanning, well-area scanning |
Wavelength Range | 250 to 900 nm |
Scanning Speed | 96: 11 seconds, 384: 22 seconds |
Wavelength Selection | Double grating monochromators / Top and Bottom |
Additional Model Specifications | Shaking: Yes Software: Gen5™ Included. Control through USB or serial port. Automation: Yes Fluorescence Intensity Sensitivity: Fluorescein 2.5 pM typical (0.25 fmol/well 384-well plate) - top Fluorescein 5 pM typical (0.5 fmol/well 384-well plate) - bottom Dynamic range: 5 decades Reagent Dispensers Number: 2 syringe pumps Dispense volume: 5 - 1000 µL in 1 µL increment Dead volume: 1.1 mL, 100 µL with back flush Regulatory: For in vitro diagnostic use. All BioTek microplate instrumentation is CE and ETL marked. For details on approvals and standards compliance, please contact BioTek. |
BioTek - Luminescence
[+] View Model SpecificationsDepth | 20.9 in |
Detector | Low noise PMT |
Height | 15 in |
Detection Mode | Multi-label |
Width | 17 in |
Power Requirements | 250 Watts max. |
Weight | 70 lbs |
Wavelength Range | 300 to 700 nm |
Additional Model Specifications | Shaking: Yes Software: Gen5™ Included. Control through USB or serial port. Automation: Yes Luminescence Sensitivity: 10 amol ATP typical (flash) Dynamic range: > 6 decades Reagent Dispensers Number: 2 syringe pumps Dispense volume: 5 - 1000 µL in 1 µL increment Dead volume: 1.1 mL, 100 µL with back flush Regulatory: For in vitro diagnostic use. All BioTek microplate instrumentation is CE and ETL marked. For details on approvals and standards compliance, please contact BioTek. |