Today's research requires that instrumentation be cost effective, reliable and easy to use. In response to those requirements, BioTek Instruments has developed the Synergy™ HT Multi-Mode Microplate Reader. This plate reader for fluorescence, absorbance and luminescence measurements was designed with an emphasis on superior performance in all detection methods. Unlike many multi-mode microplate readers, the Synergy HT utilizes a unique dual-optics design.
Active Questions & AnswersAsk a Question
Microplate Readers Service ProvidersView All (12)
Documents & ManualsView All Documents
Features of Synergy HT
- Automatic top and bottom epifluorescence read modes optimized for both sensitive homogeneous and cell-based assays
- Compatible with Take3 Multi-Volume Plate: sixteen 2 µL microspots for low volume DNA/RNA 260 nm measurements. Saves precious samples, very fast and simple process.
- Software-controlled automatic probe height adjustment with built-in plate sensor to prevent probe crashes
- Scanning monochromator for wavelength scans to identify peak absorbance and provide full spectral analysis
- Luminescence measurements with top detection for best sensitivity
- Reads 6- to 384-well microplate formats including PCR trays and Terasaki plates
- Well area scanning for popular cell-based assays
- Time-Resolved Fluorescence capability
- Dual Reagent Dispensers
- USB and serial ports for easy connectivity
- Includes Gen5™ Software
General Specifications
There are no General Specifications available.
Additional Specifications
Injection Volume Range: 5 - 1000 µL
Series Modals
BioTek - Absorbance
[+] View Model SpecificationsBandwidth | 2.4 nm |
Depth | 15 in |
Height | 10 in |
Detection Mode | Multi-label |
Width | 16 in |
Detection Method | Fluorescence, Time-Resolved Fluorescence, Luminescence, UV-Visible Absorbance |
Power Requirements | 100-240 VAC 50/60 Hz |
Sample Formats | 6- to 384-well plates; PCR plates; Compatible with Take3 Multi-Volume Plate with 2 µL microspots |
Lighting | SQ Xenon Flash |
Weight | 40 lbs |
Read Method | End-point, kinetic, spectral scanning, well-area scanning |
Wavelength Range | 200 to 999 nm |
Scanning Speed | 96: 14 seconds, 384: 26 seconds |
Wavelength Selection | Monochromator |
Additional Model Specifications | General Shaking: Yes Software: Gen5™ Included. Control through USB or serial port. Automation: Yes Absorbance Dynamic range: 0 - 4.0 OD Resolution: 0.001 OD Pathlength correction: Yes Monochromator wavelength accuracy: +/- 2 nm Monochromator wavelength repeatability: +/- 0.2 nm OD accuracy: < 1% at 2.0 OD typical < 3% at 3.0 OD typical OD linearity: < 1% from 0 to 3.0 OD typical OD repeatability: < 0.5% at 2.0 OD typical Stray light: 0.03% at 230 nm typical Reagent Dispensers Number: 2 syringe pumps Dispense volume: 5-1000 µL in 1 µL increments Dead volume: 1.1 mL, 100 µL with backflush Regulatory: For in vitro diagnostic use. All BioTek microplate instrumentation is CE and ETL marked. For details on approvals and standards compliance, please contact BioTek. |
BioTek - Fluorescence Intensity
[+] View Model SpecificationsBandwidth | Filter dependent |
Depth | 15 in |
Detector | PMT |
Height | 10 in |
Detection Mode | Multi-label |
Width | 16 in |
Detection Method | Fluorescence, Time-Resolved Fluorescence, Luminescence, UV-Visible Absorbance |
Power Requirements | 100-240 VAC 50/60 Hz |
Sample Formats | 6- to 384-well plates; PCR plates; Compatible with Take3 Multi-Volume Plate with 2 µL microspots |
Lighting | Tungsten Halogen SQ Xenon Flash |
Weight | 40 lbs |
Read Method | End-point, kinetic, spectral scanning, well-area scanning |
Wavelength Range | 200 to 700 nm |
Scanning Speed | 96 wells: 31 seconds, 384 wells: 80 seconds |
Wavelength Selection | Deep blocking filters |
Additional Model Specifications | General Shaking: Yes Software: Gen5™ Included. Control through USB or serial port. Automation: Yes Fluorescence Intensity Sensitivity: Fluorescein 5 pM typical (1 fmol/well 96 well plate) – Top and bottom Dynamic range: 5 decades Reagent Dispensers Number: 2 syringe pumps Dispense volume: 5-1000 µL in 1 µL increments Dead volume: 1.1 mL, 100 µL with backflush Regulatory: For in vitro diagnostic use. All BioTek microplate instrumentation is CE and ETL marked. For details on approvals and standards compliance, please contact BioTek. |
BioTek - Luminescence
[+] View Model SpecificationsDepth | 15 in |
Detector | Low noise PMT |
Height | 10 in |
Detection Mode | Multi-label |
Width | 16 in |
Detection Method | Fluorescence, Time-Resolved Fluorescence, Luminescence, UV-Visible Absorbance |
Sample Formats | 6- to 384-well plates; PCR plates; Compatible with Take3 Multi-Volume Plate with 2 µL microspots |
Weight | 40 lbs |
Read Method | End-point, kinetic, spectral scanning, well-area scanning |
Wavelength Range | 300 to 700 nm |
Additional Model Specifications | General Shaking: Yes Software: Gen5™ Included. Control through USB or serial port. Automation: Yes Luminescence Sensitivity: 30 amol ATP typical (flash) Dynamic range: >6 decades Reagent Dispensers Number: 2 syringe pumps Dispense volume: 5-1000 µL in 1 µL increments Dead volume: 1.1 mL, 100 µL with backflush Regulatory: For in vitro diagnostic use. All BioTek microplate instrumentation is CE and ETL marked. For details on approvals and standards compliance, please contact BioTek. |
BioTek - Time-Resolved Fluorescence
[+] View Model SpecificationsDepth | 15 in |
Height | 10 in |
Detection Mode | Multi-label |
Width | 16 in |
Detection Method | Fluorescence, Time-Resolved Fluorescence, Luminescence, UV-Visible Absorbance |
Power Requirements | 100-240 VAC 50/60 Hz |
Sample Formats | 6- to 384-well plates; PCR plates; Compatible with Take3 Multi-Volume Plate with 2 µL microspots |
Lighting | SQ Xenon Flash (optional) |
Weight | 40 lbs |
Read Method | End-point, kinetic, spectral scanning, well-area scanning |
Wavelength Selection | Monochromator |
Additional Model Specifications | General Shaking: Yes Software: Gen5™ Included. Control through USB or serial port. Automation: Yes Reagent Dispensers Number: 2 syringe pumps Dispense volume: 5-1000 µL in 1 µL increments Dead volume: 1.1 mL, 100 µL with backflush Regulatory: For in vitro diagnostic use. All BioTek microplate instrumentation is CE and ETL marked. For details on approvals and standards compliance, please contact BioTek. |