This product is Discontinued
BioTek - FLx800
Manufactured by BioTek
Incorporates powerful performance at a price much lower than traditional fluorescence-luminescence microplate readers.
The FLx800™ Multi-Detection Microplate Reader combines excellent specifications and performance with convenience and ease of use. This design incorporates powerful performance at a price much lower than traditional fluorescence-luminescence microplate readers. The FLx800 line includes several models with options that meet the specific needs of research and OEM users. Top and bottom reading are available to read anything from 6-well to 384-well microplates, and PCR plates. An optional external dispenser module allows you to run applications such as ion channel assays and flash luminescence assays (e.g. luciferase, ATP).
Active Questions & AnswersAsk a Question
Microplate Readers Service ProvidersView All (12)
Documents & ManualsView All Documents
Features of FLx800
- Custom-mapped fiber optics for optimal signal transfer
- Selectable, automated top- or bottom-probe reading for best sensitivity
- Typical fluorescence sensitivity to 5 pM sodium fluorescein
- Glow luminescence reading with top detection for best sensitivity
- Incubation to 50ºC for temperature-sensitive assays
- PCR tube-reading option available
- Reads 6- to 384-well formats and PCR plates
- Convenient front panel accessory access makes changing filters simple
- Powerful on-board data reduction software
- Computer control via Gen5™ Software
General Specifications
Bandwidth | Variable, dependent on filter |
Depth | 16 in |
Height | 9 in |
Detection Mode | Mid-level |
Width | 15 in |
Detection Method | Fluorescence, Luminescence: Low Noise Photomultiplier tube |
Power Requirements | 100-240 VAC 50/60 Hz |
Shaking Pattern | Linear shaking (I models) |
Filters | Excitation: 4 positions, Emission: 4 positions. Supplied filters: 2 excitation and 2 emission filters |
Sample Formats | 6- to 384-well plates, PCR plates (FLx800TBP) |
Lighting | Tungsten Halogen, 1000 hours lifetime |
Weight | 30 lbs |
Read Method | Endpoint, kinetic and area scanning under computer control |
Wavelength Range | 300 to 650 nm |
Scanning Speed | Kinetic, full 96-well plate in <35 seconds (depends on settings) |
Wavelength Selection | Deep blocking interference filters |
Additional Specifications
Dynamic range: 0-99.999 RFUs, 0-99.999 RLUs
Sensitivity:
Sodium fluorescein 2.5 pg/ml SF (1.3 fmol/well) typical*
Luciferase 0.1 pg/well typical
ATP 100 amol/well limit of detection
(*Black plate, top measurement, 3mm diameter probe)
Standard probes: 3.0 mm top, 5.0 mm bottom
Reagent dispensers: 1 syringe pump
Dispense volume: 5-1000 µl in 1 µl increments
Onboard software: 55 user-programmable protocols
PC Software: KCjunior, KC4 (optional)
Regulatory: For in-vitro diagnostic use (Except in the European Union).
All BioTek microplate instrumentation is CE and ETL marked. For details
on approvals and standards compliance, please contact BioTek.