KD Scientific - Legato 200
KDS Legato 200 infuse only syringe pump
LEGATO INHERITS KD SCIENTIFIC'S LEGENDARY RELIABILITY
Our experience in pumps and fluidics was used to create the Legato 200 Series. Over the years, customers had asked to display more information simultaneously and make it easier to configure and run complicated multi-step programs. The high resolution touch screen interface offers unparalleled ease of use. Today’s demanding applications require better flow performance and repeatability down to 1 nl/hr. Legato offers 0.35% accuracy and 0.5% repeatability.
DESIGNED TO MEET TODAY’S CHALLENGES
In today’s economic environment, multiple users with different experiments are using the same pump. The next generation of pump had to meet this demand to store and recall multiple programs. The pumps role in the experiment now changes more readily with multiple users and multiple tests being done using a single pump.
ENGINEERED TO MEET GLOBAL REGULATORY COMPLIANCE
Worldwide use of our pumps and changing regulatory compliance meant designing the pump to meet RoHS and WEEE, CE, UL, CSA, and CB schemes. The Legato has lead free boards and is designed to the latest safety and EMI/RFI standards.
Active Questions & AnswersAsk a Question
Recent Questions & Answers
Lab Pumps Service ProvidersView All (3)
Documents & Manuals
There are no Documents or Manuals available.
Features of Legato 200
- Holds one or two syringes from 0.5ul to 140ml* High resolution color touch screen* Real time clock* Unparallel ease of use* Touch pad "lock" feature* LED light on front panel* Full metal chassis* Built in syringe table* Up to 75 lbs linear force* Advanced microstepping techniques* Built in RS485 interface* USB port* I/O & TTL interface* Continuous mode of operation* Spill dam
General Specifications
There are no General Specifications available.
Additional Specifications
Accuracy:
± 0.35%
Reproducibility
± 0.05%
Syringes (Min/Max)
0.5 ul to 140ml
Flow Rate:
Minimum (0.5 ul syringe): 5pl/min
Maximum (140ml syringe): 220.97 ml/min
Display
4.3 WQVGA TFT Color Display with Touchpad
Non-Volatile Memory
Stores all Settings
Connectors:
RS232 - 9Pin D-Sub Connector
RS485 - IEEE-1394 6 pos
USB - Type B
I/O & TTL - 15 pin D-Sub Connector
Linear Force (Max)
34 kg (75 lbs) @ 100% Force Selection
Drive Motor
1.8 degree Stepper Motor
Motor Drive Control
Microprocessor with 1/16 microstepping
Number of Microsteps (per one rev.of Lead Screw)
6,400
Step Rate - Minimum
27.5 sec/ustep
Step Rate - Maximum
26 usec/ustep
Pusher Travel Rate - Minimum
0.36 um/min
Pusher Travel Rate - Maximum
190.80 mm/min
Power
100-240 VAC: 50/60 Hz, 50 W, 0.5 A fuse
Dimensions
8.89 x 25.4 x 27.94 cm (3.5 x 10 x 11 in)
Weight
4.9 Kg (10.75 lb)
Operating Temperature
4 degree'C to 40 degree C (40 degree F to 104 degree F)
Storage Temperature
-10 degreeC to 70 degree C (14 degree F to 158 degree F)
Humidity
20% to 80% RH non condensing
Mode of Operation
Continuous
Classification
Class 1
Pollution Degree
1
Installation Category
11
Regulatory Certification
CE, UL, CSA, CB Scheme, EU RoHS
Videos
KD Scientific introduces the new Legato 200 series syringe pumps