Thermo Scientific - ITQ™ Series GC-Ion Trap MS Systems

Manufactured by  Thermo Scientific
Follow this Equipment

With full-scan electron ionization sensitivity and upgradeability, Thermo Scientific™ ITQ™ Series GC-Ion...

With full-scan electron ionization sensitivity and upgradeability, Thermo Scientific™ ITQ™ Series GC-Ion Trap MS Systems have the flexibility to grow from small-footprint entry-level QA/QC instruments to fully featured, research-grade systems with advanced MSn functionality. ITQ Series systems offer a broad range of standard features with an impressive list of upgrade options. As your needs change, you can expand instrument capabilities and add flexibility and versatility. The series is supported by Productivity Solutions and workflow-oriented software packages.
Active Questions & AnswersAsk a Question

There are no current Discussions

Ion Trap Systems Service ProvidersView All (42)

Request Support
Documents & Manuals

There are no Documents or Manuals available.

Features of ITQ™ Series GC-Ion Trap MS Systems
External Ionization Ion Source       
  • Standard on all ITQ systems with independently controlled heating from 125° to 300°C for stable operation and excellent chromatographic integrity       
  • Enhanced spectral integrity when ionization takes place external to the trap, so the system stays cleaner, longer for improved uptime and longer periods between cleaning                Quadrupole Ion Trap Mass Analyzer       
  • Unit mass resolution throughout the mass range       
  • Durable inert materials for long life       
  • Automatic gain control ensures that the ion trap is always filled with the optimum number of ions                Detection System       
  • Digital electronic noise discrimination enhances sensitivity       
  • Post-acceleration +10kV conversion dynode offers efficient positive and negative ion detection                Configurations Available for ITQ Series       
  • Direct Sample Probe       
  • Directly analyze solids or liquids without chromatographic separation and without moving the GC by using the Direct Sample Probe                Chemical Ionization       
  • Optional chemical ionization increases selectivity and sensitivity       
  • Both positive and negative chemical ionization modes supported; digital reagent gas flow control ensures method stability and reproducibility                Features Standard on the ITQ 1100 GC-Ion Trap MS; Optional for the ITQ 700 GC-Ion Trap MS; and ITQ 900 GC-Ion Trap MS       
  • MSn with ACE and PQD       
  • Capability to routinely test for compounds in the matrix that cannot typically be detected with other GC/MS techniques       
  • Automated Collision Energy (ACE): Sutomatically calculates an estimated optimal collision energy based on product ion m/z and damping gas flow rates; runs at three energies across each scan       
  • Pulsed Q Dissociation Mode (PQD): Generates information-rich mass spectral data, even in the low mass range; produces precise, reproducible fragmentation                Vacuum Probe Interlock       
  • Restore system performance, change from EI to Cl or use the direct sample probe—all without venting the instrument using the Vacuum Probe Interlock
  • General Specifications

    There are no General Specifications available.

    Looking for New or Used Equipment?

    Shop on LabX

    Shop on Labx.com