Labconco - Protector ClassMate
Manufactured by Labconco
Protector ClassMate Laboratory Hoods
The redesigned Protector® ClassMate® chemical fume hood. The new design is the first full view fume hood that meets the SEFA definition of a high performance hood. This means it has been ASHRAE 110 containment tested with the sash fully open (28” above the work surface) at a 60 feet per minute (fpm) face velocity, and there was less than an average of 0.05 ppm of the Sulfur Hexafluoride (SF6) tracer gas detected. In fact, the test reports show the new ClassMate exceeded those requirements, and show an average of 0.00 ppm of detected SF6!
The patented Protector ClassMate Laboratory Hood is designed to meet the needs of instructional laboratories. Clear back and sides and taller front viewing window provide enhanced visibility for conducting chemistry demonstrations or observing students using the hood. The clear back also does not obstruct visibility when hoods are placed back-to-back in an island configuration.
Fully-featured with baffle and air foil, this by-pass hood maintains safe airflow while the restricted sash opening conserves energy. The Protector ClassMate Hood is benchtop design and offered in 4', 5', and 6' widths. HOPEC IV models with combination A-style sashes are also available.
The patented Protector ClassMate Laboratory Hood is designed to meet the needs of instructional laboratories. Clear back and sides and taller front viewing window provide enhanced visibility for conducting chemistry demonstrations or observing students using the hood. The clear back also does not obstruct visibility when hoods are placed back-to-back in an island configuration.
Fully-featured with baffle and air foil, this by-pass hood maintains safe airflow while the restricted sash opening conserves energy. The Protector ClassMate Hood is benchtop design and offered in 4', 5', and 6' widths. HOPEC IV models with combination A-style sashes are also available.
Active Questions & AnswersAsk a Question
There are no current Discussions
Fume Hoods Service ProvidersView All (9)
Documents & ManualsView All Documents
Features of Protector ClassMate
- Clear, 1/4" thick, tempered safety glass sides, back and baffle provide maximum visibility and are removable for cleaning.
- Unique sash conserves energy yet provides maximum height visibility of 39".
- Ergonomic 5º angled sash and panel allow closer, more comfortable viewing, without glare.
- Vertical-rising sash from closed to 29" fully open height for loading and cleaning
- 8.63" ID epoxy-coated steel exhaust connection
- Anti-racking shaft provides smooth vertical sash movement.
- By-pass airflow design
- Tissue screen located directly below the exhaust outlet prevents debris from potentially damaging the remote blower.
- Interior cover plates are removable for easy access to plumbing.
- Pre-wired lighting, light and blower switches
- Curved air foil allows air to sweep the work surface while Clean-Sweep™ openings pull inflow air from under the air foil.
- Low profile trough below air foil contains spills.
- Frame of glacier white epoxy-coated steel and aluminum
- Streamlined corner posts provide maximum visibility and working area.
- Factory-prepared for up to 8 service fixtures.
- Factory-prepared for up to 2 pre-wired electrical duplex receptacles
- ETL listed
- Removable front panel and interior cover plates for access to plumbing and electrical wiring
Options
- 4’, 5’ and 6’widths
- Combination Sash Models
Required Accessories
- Base cabinets
- Adjustable Height Base stands
- Remote blowers
- Ductwork
- SpillStopper™ Work Surfaces
General Specifications
There are no General Specifications available.
Additional Specifications
Product Subcategory: Educational
Nominal Width: 4'
Electrical Requirements: Domestic
Blower Requirements: Remote blower required
Air Usage/Static Pressure with Sash Open 18
Series Modals
Labconco - 4ft Protector ClassMate
[+] View Model SpecificationsAirflow (CFM) | 570 CFM |
Depth | 32.25 in |
Height | 59 in |
Width | 48 in |
Power Requirements | 115 V, 60 Hz, 15 A, Domestic |
Lighting | T8 fluorescent |
Construction | Dry-powder glacier white epoxy-coated steel and aluminum frame |
Face Velocity (FPM) | 100 |
Fume Hood Type | Variable Air Volume Ducted |
Additional Model Specifications | Product Subcategory: Educational Style: Benchtop Nominal Width: 4' Blower Requirements: Remote blower required Compliance: SEFA 1-2002, ASHRAE 110-95, ANSI Z9.5-1993, UL 3101-1/61010-1 Air Usage/Static Pressure with Sash Open 18": At 100 fpm, exhausts 570 CFM at 0.24" H2O static pressure Models 6970401 & 6971401: Service Fixtures: 4 Electrical Duplexes: 2 Models 6971400 & 6971401 4' Protector ClassMate HOPEC IV Laboratory Hood, ADA-compliant hand operated positive energy control design, angled tempered safety glass vertical-rising sash and viewing window. |
Labconco - 5ft Protector ClassMate
[+] View Model SpecificationsAirflow (CFM) | 730 CFM |
Depth | 32.25 in |
Height | 59 in |
Width | 60 in |
Power Requirements | 115 V, 60 Hz, 15 A, Domestic |
Lighting | T8 fluorescent |
Construction | Dry-powder glacier white epoxy-coated steel and aluminum frame |
Face Velocity (FPM) | 100 |
Fume Hood Type | Variable Air Volume Ducted |
Additional Model Specifications | Product Subcategory: Educational Style: Benchtop Nominal Width: 5' Blower Requirements: Remote blower required Compliance: SEFA 1-2002, ASHRAE 110-95, ANSI Z9.5-1993, UL 3101-1/61010-1 Air Usage/Static Pressure with Sash Open 18": At 100 fpm, exhausts 730 CFM at 0.39" H2O static pressure Model 6970501 & 6971501: Service Fixtures: 4 Electrical Duplexes: 2 Models 6971500 & 6971501 4' Protector ClassMate HOPEC IV Laboratory Hood, ADA-compliant hand operated positive energy control design, angled tempered safety glass vertical-rising sash and viewing window. |
Labconco - 6ft Protector ClassMate
[+] View Model SpecificationsAirflow (CFM) | 890 CFM |
Depth | 32.25 in |
Height | 59 in |
Width | 72 in |
Power Requirements | 115 V, 60 Hz, 15 A, Domestic |
Lighting | T8 fluorescent |
Construction | Dry-powder glacier white epoxy-coated steel and aluminum frame |
Face Velocity (FPM) | 100 |
Fume Hood Type | Variable Air Volume Ducted |
Additional Model Specifications | Product Subcategory: Educational Style: Benchtop Nominal Width: 6' Blower Requirements: Remote blower required Compliance: SEFA 1-2002, ASHRAE 110-95, ANSI Z9.5-1993, UL 3101-1/61010-1 Air Usage/Static Pressure with Sash Open 18": At 100 fpm, exhausts 890 CFM at 0.51" H2O static pressure Models 6970601 & 6971601: Service Fixtures: 4 Electrical Duplexes: 2 Models 6971600 & 6971601 4' Protector ClassMate HOPEC IV Laboratory Hood, ADA-compliant hand operated positive energy control design, angled tempered safety glass vertical-rising sash and viewing window. |