Labconco - Protector Work Stations without Blower
Manufactured by Labconco
Protector Work Stations with Built-In Blower
Protector Work Stations are specifically designed for the needs of pathologists and histotechnologists. Like a traditional fume hood, these enclosures have a front air foil and rear baffle to direct the inflow air across the work area and away from the operator. Ideal for cramped or crowded labs, Protector Work Stations have a low profile so they fit easily under standard upper cabinets.
Protector Work Stations designed for ducting to the outside are available with or without a built-in blower. If there is no feasible way to vent to the outside, models with a built-in blower are available that use specially-treated Carbon Filters. These filter packs keep low level concentrations of toluene, xylene, formalin, formaldehyde and other solvents below their OSHA-recommended, time-weighted averages, restoring clean air to the laboratory. Complete and e-mail the Chemical Usage Assessment Form to receive a technical analysis of the right product for your application.
Protector Work Stations designed for ducting to the outside are available with or without a built-in blower. If there is no feasible way to vent to the outside, models with a built-in blower are available that use specially-treated Carbon Filters. These filter packs keep low level concentrations of toluene, xylene, formalin, formaldehyde and other solvents below their OSHA-recommended, time-weighted averages, restoring clean air to the laboratory. Complete and e-mail the Chemical Usage Assessment Form to receive a technical analysis of the right product for your application.
Active Questions & AnswersAsk a Question
There are no current Discussions
Fume Hoods Service ProvidersView All (9)
Documents & ManualsView All Documents
Features of Protector Work Stations without Blower
Features
- Face velocities from 60 to 100 fpm
- Built-in dynamically-balanced motorized impeller
- Speed control to achieve desired inflow velocity
- Ergonomic air foil with aerodynamic Clean-Sweep airflow openings
- Upper dilution air supply
- Zone-perforated Type 304 stainless steel rear baffle
- Side-entry air foils
- Glacier white and gray, dry powder epoxy-coated aluminum frame and steel rear plenum and baffle
- 1/4" thick tempered safety glass front sash and sides
- 8" high sash opening
- Ergonomic 20° angled and hinged sash with wiping seals and spring-loaded latch that pivots upward and locks to a 20" height
- Glare-free fluorescent lighting
- Light and blower switches
- Exterior rear-mounted electrical receptacle
- Baffle with two release knobs that pivots down for filter access
- Low discharge volume and quiet operation
- SpillStopper™ Work Surfaces
- Supporting Base
- Remote blower, house exhaust or FilterMate™ Portable Exhauster
- Ductwork
General Specifications
There are no General Specifications available.
Additional Specifications
Product Subcategory: General Chemistry
Nominal Width: 4'
Electrical Requirements: Domestic
Blower Requirements: Remote blower or FilterMate Portable Exhauster and filters required
Compliance: SEFA 1-2002, Modified ASHRAE 110-1995, ANSI Z9.5-1993, UL 3101-1/61010-1, CAN/CSA C22.2 No. 1010.1
Style: Benchtop
Air Usage/Static Pressure with Sash At Working Height: At 60 fpm, exhausts 150 CFM at .06" H2O maximum external static pressure
Power Cord & Plug: 6.5' power cord with plug.
Series Modals
Labconco - 3930001
[+] View Model Specifications| Airflow (CFM) | 150 CFM |
| Depth | 29 in |
| Height | 25.7 in |
| Width | 48 in |
| Power Requirements | 115 volts, 60 Hz, 10 amps, Domestic |
| Lighting | Fluorescent |
| Face Velocity (FPM) | 60 FPM |
| Fume Hood Type | Conventional Ducted |
| Additional Model Specifications | Product Subcategory: General Chemistry
Style: Benchtop Nominal Width: 4' Blower Requirements: Remote blower or FilterMate Portable Exhauster and filters required Compliance: SEFA 1-2002, Modified ASHRAE 110-1995, ANSI Z9.5-1993, UL 3101-1/61010-1, CAN/CSA C22.2 No. 1010.1 Style: Benchtop Air Usage/Static Pressure with Sash At Working Height: At 60 fpm, exhausts 150 CFM at .06" H2O maximum external static pressure Power Cord & Plug: 6.5' power cord with plug. |
Labconco - 3930021
[+] View Model Specifications| Airflow (CFM) | 150 CFM |
| Depth | 29 in |
| Height | 25.7 in |
| Width | 48 in |
| Power Requirements | 230 V, 50 Hz, 5 A, International |
| Lighting | Fluorescent |
| Face Velocity (FPM) | 60 FPM |
| Fume Hood Type | Conventional Ducted |
| Additional Model Specifications | Product Subcategory: General Chemistry
Style: Benchtop Nominal Width: 4' Blower Requirements: Remote blower or FilterMate Portable Exhauster and filters required Compliance: SEFA 1-2002, Modified ASHRAE 110-1995, ANSI Z9.5-1993, UL 3101-1/61010-1, CAN/CSA C22.2 No. 1010.1 Style: Benchtop Air Usage/Static Pressure with Sash At Working Height: At 60 fpm, exhausts 150 CFM at .06" H2O maximum external static pressure Power Cord & Plug: 9' power cord without plug. |