Purifier Logic Class II, Type A2 Biosafety Cabinets provide personnel, product and environmental protection from...
Purifier Logic Class II, Type A2 Biosafety Cabinets provide personnel, product and environmental protection from hazardous particulates such as agents that require Biosafety Level 1, 2 or 3 containment. Other appropriate applications include work with antineoplastic drugs, genetic material, carcinogens, allergens and additional substances that generate hazardous airborne particulates. All models are NSF-Listed.
During operation, room air is drawn into the inlet grille at the work access opening and through a supply HEPA filter. Approximately 70% of the HEPA-filtered air is circulated through the cabinet, while 30% passes through an exhaust HEPA filter and is discharged. These biohazard cabinets are designed to discharge HEPA-filtered exhaust air directly into the laboratory, or into an exhaust system through the optional Canopy Connection. When canopy-ducted, these biological safety cabinets may be used for applications involving minute quantities of volatile toxic chemicals and tracer amounts of radionuclides as an adjunct to microbiological research.
During operation, room air is drawn into the inlet grille at the work access opening and through a supply HEPA filter. Approximately 70% of the HEPA-filtered air is circulated through the cabinet, while 30% passes through an exhaust HEPA filter and is discharged. These biohazard cabinets are designed to discharge HEPA-filtered exhaust air directly into the laboratory, or into an exhaust system through the optional Canopy Connection. When canopy-ducted, these biological safety cabinets may be used for applications involving minute quantities of volatile toxic chemicals and tracer amounts of radionuclides as an adjunct to microbiological research.
Active Questions & AnswersAsk a Question
Recent Questions & Answers
Biological Safety Cabinets Service ProvidersView All (5)
Documents & ManualsView All Documents
Features of Purifier Logic Type A2
- Nominal inflow velocity of 105 fpm (0.5 m/sec)
- Nominal downflow velocity of 55 fpm (0.3 m/sec)
- Patent-pending design
- Interior-mounted, line-of-sight LCD information center with "Filter Life Remaining" bar graph, status line for alarm conditions and alerts to warn when filter life diminishes to 20%, 10% and 0%
- Filter monitoring system consisting of an electronically commutated motor (ECM) that delivers a precise volume of air as required and automatically adjusts as filters load without relying on airflow sensors
- Smart-Start™ System that allows the user to program start up and shut down operations
- Night-Smart™ System that idles the blower when the sash is fully closed
- Built-in interval or elapsed timer for experiment monitoring or UV light control (on models with UV light)
- Touchpad control on right-hand side post for manual activation of blower, light, timer, audible alarm mute and menu selection
- Radiused type 304 stainless steel interior and removable, seamless, dished work surface with lift out knobs
- Epoxy-coated steel exterior
- Towel catch located under work surface
- Contain-Air™ Negative Pressure Channel
- Class 5 conditions per ISO 14644-1 and 2 (formerly Class 100)
- Supply and exhaust 99.99% efficient HEPA filters
- Two electrical duplex receptacles, (single outlets on 230 volt models), located one on each side, with ground fault interruption and stainless steel splash covers
- Fully-closing, clear 1/4" tempered safety glass sash with two sash handles; counterbalanced, anti-racking mechanism; and 10° slope
- 29" sash opening viewing height
- Curved stainless steel inlet grille with Reserve-Air™ Secondary Airflow Slots
- Bright, 100 foot-candle, glare-free fluorescent lighting located outside the contaminated work area
- Intrinsically safe negative pressure design
- Electronic security lock (optional activation) that requires code to operate the cabinet
- Full three year warranty
- NSF-Listed
- ETL listed (115 volt, 60 Hz models)
- CE conformity (230 volt, 50 Hz models)
- EN 12469 compliant (3440830 and 3440831 models)
General Specifications
There are no General Specifications available.
Additional Specifications
Nominal Width: 3'
Electrical Requirements: Domestic
Sash Opening: 10
Series Modals
Labconco - 3' Purifier Logic
[+] View Model Specifications| Airflow (CFM) | 279 CFM |
| Depth | 31.2 in |
| Height | 63.4 in |
| Width | 42.3 in |
| Power Requirements | Available in Domestic and International |
| Lighting | Fluorescent |
| Cabinet Type | Class II Type A2 |
| Construction | Stainless steel interior, epoxy-coated steel exterior |
| Additional Model Specifications | *Domestic and International versions may vary slightly in height and width.
Nominal Width: 3' Sash opening: Available in 8' and 10' Compliance: NSF, CE, ADA Listing: NSF, CE Inflow velocity: 105 FPM Downflow velocity: 55 FPM [u]Power supply:[/u] Domestic: 115 volts, 60 Hz, 12 amps 10' width: 3430000, 3430001 8' width: 3430800, 3430801 International: 230 volts, 50/60 Hz, 6 amps [u]British (UK):[/u] 10' width: 3430020, 3430021 8' width: 3430820, 3430821 [u]Schuko:[/u] 10' width: 3430022, 3430023 8' width: 3430822, 3430823 [u]China/Australia[/u] 10' width: 3430024, 3430025 8' width: 3430824, 3430825 [u]North America:[/u] 10' width: 3430026, 3430027 8' width: 3430826, 3430827 International: 100V, 50/60 Hz, 12 amps 3430810, 3430811 [u]Also available: [/u] Built In Options: UV Light, 1 service fixture |
Labconco - 4' Purifier Logic
[+] View Model Specifications| Airflow (CFM) | 370 CFM |
| Depth | 31.2 in |
| Height | 63.4 in |
| Width | 54.3 in |
| Power Requirements | Available in Domestic and International |
| Lighting | Fluorescent |
| Cabinet Type | Class II Type A2 |
| Construction | Stainless steel interior, epoxy-coated steel exterior |
| Additional Model Specifications | *Domestic and International versions may vary slightly in height and width.
Nominal Width: 4' Sash opening: Available in 8' and 10' Compliance: NSF, ETL, UL 61010-1, ADA Listing: NSF, ETL Inflow velocity: 105 FPM Downflow velocity: 55 FPM [u]Power supply:[/u] Domestic: 115 volts, 60 Hz, 12 amps 10' width: 3440000, 3440001 8' width: 3440800, 3440801 International: 230 volts, 50/60 Hz, 6 amps [u]British (UK):[/u] 10' width: 3440020, 3440021 8' width: 3440820, 3440821 [u]Schuko:[/u] 10' width: 3440022, 3440023 8' width: 3440822, 3440823 [u]China/Australia[/u] 10' width: 3440024, 3440025 8' width: 3440824, 3440825 [u]North America:[/u] 10' width: 3440026, 3440027 8' width: 3440826, 3440827 International: 100V, 50/60 Hz, 12 amps 3440810, 3440811 [u]Also available: [/u] Built In Options: UV Light, 1 service fixture |
Labconco - 5' Purifier Logic
[+] View Model Specifications| Airflow (CFM) | 462 CFM |
| Depth | 31.2 in |
| Height | 63.4 in |
| Width | 66.3 in |
| Power Requirements | Available in Domestic and International |
| Lighting | Fluorescent |
| Cabinet Type | Class II Type A2 |
| Construction | Stainless steel interior, epoxy-coated steel exterior |
| Additional Model Specifications | *Domestic and International versions may vary slightly in height and width.
Nominal Width: 5' Sash opening: Available in 8' and 10' Compliance: NSF, ETL, UL 61010-1, ADA Listing: NSF, ETL Inflow velocity: 105 FPM Downflow velocity: 55 FPM [u]Power supply:[/u] Domestic: 115 volts, 60 Hz, 12 amps 10' width: 3450000, 3450001 8' width: 3450800, 3450801 International: 230 volts, 50/60 Hz, 6 amps [u]British (UK):[/u] 10' width: 3450020, 3450021 8' width: 3450820, 3450821 [u]Schuko:[/u] 10' width: 3450022, 3450023 8' width: 3450822, 3450823 [u]China/Australia[/u] 10' width: 3450024, 3450025 8' width: 3450824, 3450825 [u]North America:[/u] 10' width: 3450026, 3450027 8' width: 3450826, 3450827 International: 100V, 50/60 Hz, 12 amps 3450810, 3450811 [u]Also available: [/u] Built In Options: UV Light, 1 service fixture |
Labconco - 6' Purifier Logic
[+] View Model Specifications| Airflow (CFM) | 554 CFM |
| Depth | 31.2 in |
| Height | 63.4 in |
| Width | 78.3 in |
| Power Requirements | Available in Domestic and International |
| Lighting | Fluorescent |
| Cabinet Type | Class II Type A2 |
| Construction | Stainless steel interior, epoxy-coated steel exterior |
| Additional Model Specifications | *Domestic and International versions may vary slightly in height and width.
Nominal Width: 6' Sash opening: Available in 8' and 10' Compliance: NSF, ETL, UL 61010-1, ADA Listing: NSF, ETL Inflow velocity: 105 FPM Downflow velocity: 55 FPM [u]Power supply:[/u] Domestic: 115 volts, 60 Hz, 12 amps 10' width: 3460000, 3460001 8' width: 3460800, 3460801 International: 230 volts, 50/60 Hz, 6 amps [u]British (UK):[/u] 10' width: 3460020, 3460021 8' width: 3460820, 3460821 [u]Schuko:[/u] 10' width: 3460022, 3460023 8' width: 3460822, 3460823 [u]China/Australia[/u] 10' width: 3460024, 3460025 8' width: 3460824, 3460825 [u]North America:[/u] 10' width: 3460026, 3460027 8' width: 3460826, 3460827 International: 100V, 50/60 Hz, 12 amps 3460810, 3460811 [u]Also available: [/u] Built In Options: UV Light, 1 service fixture |