Features of Labgard 425
Generous room The industry's largest workspace allows you to place all items required for a complete procedure within the work zone thereby minimizing air barrier penetration, reducing possible escape of contaminants from the work zone.
Unequaled reliability Without a doubt, the NU-425's mean-time-between-failures (MTBF) is the industry's highest. Reliability must be built-in from the ground up. Only the highest quality parts are demanded by our customers and provided by our vendors.
Greater accessibility The large ten-inch work access opening allows personnel more freedom and better protection.
Less reach You're not only more comfortable with the interior work tray closer to you, but the ergonomic design and optional accessories such as the stainless steel turntable encourages proper work technique, so you work smarter, safer and more efficiently.
Minimal eye fatigue The lightweight, nonreflecting sliding glass view screen with the frameless polished edge design and cool white diffused lighting provides an unobstructed view of your work and reduces eye fatigue.
Quieter, safer, more efficient operation NuAire's HEPEX Zero leak Air Flow system, places a negative pressure around all positive pressure plenums, even down to the HEPA filter interface with the work zone, insuring a continuing bio-clean environment.
General Specifications
There are no General Specifications available.
Series Modals
NuAire - NU-425-200
[+] View Model SpecificationsDepth | 24 in |
Height | 50 in |
Internal Depth | 19 in |
Internal Height | 23.5 in |
Width | 28.5 in |
Internal Width | 24.5 in |
Power Requirements | 11 |
Lighting | Fluorescent, 90 (968) to 120 (1291) foot-candles (LUX), UV optional |
Noise Level | 63 dB |
Cabinet Type | Class II Type A2 |
Construction | All welded stainless steel 16GA, Type 304 pressure tight design |
Additional Model Specifications | Nominal size: 2' Power supply: 115 VAC / 60 Hz 100 VAC / 50-60 Hz 230 VAC / 50 Hz 230 VAC / 60 Hz |
NuAire - NU-425-300
[+] View Model SpecificationsDepth | 32.9 in |
Height | 63 in |
Internal Depth | 23.5 in |
Internal Height | 28.5 in |
Width | 41.6 in |
Internal Width | 34.4 in |
Lighting | Fluorescent, 90 (968) to 120 (1291) foot-candles (LUX), UV optional |
Noise Level | 63 dB |
Cabinet Type | Class II Type A2 |
Construction | All welded stainless steel 16GA, Type 304 pressure tight design |
Additional Model Specifications | Nominal size: 3' Power supply: 115 VAC / 60 Hz 100 VAC / 50-60 Hz 230 VAC / 50 Hz 230 VAC / 60 Hz |
NuAire - NU-425-400
[+] View Model SpecificationsDepth | 32.9 in |
Height | 63 in |
Internal Depth | 23.5 in |
Internal Height | 28.5 in |
Width | 53.6 in |
Internal Width | 46.6 in |
Lighting | Fluorescent, 90 (968) to 120 (1291) foot-candles (LUX), UV optional |
Noise Level | 63 dB |
Cabinet Type | Class II Type A2 |
Construction | All welded stainless steel 16GA, Type 304 pressure tight design |
Additional Model Specifications | Nominal size: 4' Power supply: 115 VAC / 60 Hz 100 VAC / 50-60 Hz 230 VAC / 50 Hz 230 VAC / 60 Hz |
NuAire - NU-425-500
[+] View Model SpecificationsDepth | 32.9 in |
Height | 63 in |
Internal Depth | 23.5 in |
Internal Height | 28.5 in |
Width | 65.6 in |
Internal Width | 58.6 in |
Lighting | Fluorescent, 90 (968) to 120 (1291) foot-candles (LUX), UV optional |
Noise Level | 63 dB |
Cabinet Type | Class II Type A2 |
Construction | All welded stainless steel 16GA, Type 304 pressure tight design |
Additional Model Specifications | Nominal size: 5' Power supply: 115 VAC / 60 Hz 100 VAC / 50-60 Hz 230 VAC / 50 Hz 230 VAC / 60 Hz |
NuAire - NU-425-600
[+] View Model SpecificationsDepth | 32.9 in |
Height | 63 in |
Internal Depth | 23.5 in |
Internal Height | 28.5 in |
Width | 77.6 in |
Internal Width | 70.4 in |
Lighting | Fluorescent, 90 (968) to 120 (1291) foot-candles (LUX), UV optional |
Noise Level | 63 dB |
Cabinet Type | Class II Type A2 |
Construction | All welded stainless steel 16GA, Type 304 pressure tight design |
Additional Model Specifications | Nominal size: 6' Power supply: 115 VAC / 60 Hz 100 VAC / 50-60 Hz 230 VAC / 50 Hz 230 VAC / 60 Hz |