Rigel Medical - UNI-SIM Lite
Manufactured by Rigel Medical
The UNI-SiM Lite is a handheld and battery-operated vital signs simulator, designed to be a cost effective and portable...
The UNI-SiM Lite is a handheld and battery-operated vital signs simulator, designed to be a cost effective and portable solution for carrying out spot checks and full PM’s on vital signs monitors, wherever the job takes you.
With synchronized vital signs parameters, fast boot up and single button simulation to repeat the last simulation value in seconds, the UNI-SiM Lite is a quick and easy-to-use simulator for basic spot checks.
User configurable heart rate, SpO2 values, systolic and diastolic NiBP pressures make the UNI-SiM Lite a truly versatile tool capable of meeting even the most demanding test protocols.
Compatibility with the Rigel PULS-R universal SpO2 simulation finger enables accurate and repeatable SpO2 values. Unique probe positioning LEDS help to ensure the correct positioning of SpO2 probes, improving accuracy and repeatability
With synchronized vital signs parameters, fast boot up and single button simulation to repeat the last simulation value in seconds, the UNI-SiM Lite is a quick and easy-to-use simulator for basic spot checks.
User configurable heart rate, SpO2 values, systolic and diastolic NiBP pressures make the UNI-SiM Lite a truly versatile tool capable of meeting even the most demanding test protocols.
Compatibility with the Rigel PULS-R universal SpO2 simulation finger enables accurate and repeatable SpO2 values. Unique probe positioning LEDS help to ensure the correct positioning of SpO2 probes, improving accuracy and repeatability
Active Questions & AnswersAsk a Question
There are no current Discussions
Miscellaneous Service ProvidersView All (3)
Documents & ManualsView All Documents
Features of UNI-SIM Lite
- Compact and cost-effective * Simultaneous vital signs simulation * Fast start up and single button simulation * User definable systolic and NiBP simulations * Universal SpO2 simulation * Easy and accurate probe placement with PULS-R
General Specifications
Depth | 3 in |
Height | 10.8 in |
Width | 4 in |
Power Requirements | 100-240VAC |
Weight | 3.5 lbs |
Additional Specifications
Operation
Battery cell, in-situ charge
Supply
12VDC centre positive
Battery Life
8 hours standby or a maximum of 200 NiBP simulations
Communication
Via Blue Tooth
Display
Monochorme, ¼VGA full graphics
Keypad
Alpha-numeric
Operating Conditions
50?F-86?F, 0-90% RH - NC
Storage Environment
5?F - +140?F
Environmental Protection
IP 40