This product is Discontinued
Beckman Coulter - Avanti J Series
Manufactured by Beckman Coulter
The Beckman Coulter Avanti® J Series features performance capabilities unattainable with high speed or super speed...
The Beckman Coulter Avanti® J Series features performance capabilities unattainable with high speed or super speed centrifuges. New rotors enable forces of over 110,000 g. Features include a high-torque SR Drive* for the fastest acceleration and deceleration possible with gentle precision. All models feature automatic rotor identification and imbalance safety check, CFC-free refrigerants, FRS (Friction Reduction System), and accommodate all Beckman Coulter J rotors.
The Avanti J-30I High-Performance Centrifuge System gives you the fastest separations possible - in the shortest amount of time. Swinging-bucket and fixed-angle rotors provide maximum separation forces in excess of 100,000 x g at speeds up to 30,000 rpm. Your productivity is ensured by unmatched accel/decel rates and an easy run set-up. Your sample spends more time at full force and less time in the centrifuge.
The Avanti J-30I High-Performance Centrifuge System gives you the fastest separations possible - in the shortest amount of time. Swinging-bucket and fixed-angle rotors provide maximum separation forces in excess of 100,000 x g at speeds up to 30,000 rpm. Your productivity is ensured by unmatched accel/decel rates and an easy run set-up. Your sample spends more time at full force and less time in the centrifuge.
Active Questions & AnswersAsk a Question
Recent Questions & Answers

Updated byFixerOfThings
Centrifuge Service ProvidersView All (22)
Documents & ManualsView All Documents
Features of Avanti J Series
Near-Ultracentrifuge Forces
- Over 100,000 x g means fast protein separations in the Avanti J-30I and the JA-30.50, the highest g-force fixed-angle rotor available in a high-performance centrifuge
- Subcellular organelles effectively separated by rate zonal centrifugation with the JS-24.38, a 6 x 38 mL swinging-bucket rotor
High Throughput
- Four-liter batch throughput for bacteria and cell membrane isolation using the JLA-9.1000 J-LITE® rotor at 16,800 x g
- DNA sample preparation in up to 10 microplates with the JS-5.9 Rotor
Fast and Efficient
- Fastest accel and decel times with exclusive SR Drive** technology
- Low heat output and low energy consumption
General Specifications
There are no General Specifications available.
Additional Specifications
Maximum Capacity 4 liters
Maximum Force (RCF x g) 110,500 x g
Single Tube Volume Range 1.5 - 1,000 mL
Set Temp Range (1° increments) -20°C to 40°C
Dimensions H x D x W 865 mm x 876 mm x 711 mm (34.1 in. x 34.5 in. x 28 in.)
Weight 310 kg (680 lb.)
Series Modals
Beckman Coulter - Avanti J-26 XP
[+] View Model SpecificationsDepth | 34.5 in |
Height | 34.1 in |
Width | 28 in |
Orientation | Floor Standing |
Noise Level | 57 dB |
Weight | 640 lbs |
Speed Range | 100 to 26000 rpm |
Centrifuge Type | High Speed |
Maximum Capacity | 6 liters (single tube volume range: 1.5 - 1,000 mL) |
Maximum RCF | 82000 xg |
Maximum Speed | 26000 rpm |
Refrigerated | No_ |
Additional Model Specifications | Approximate Acceleration Time: Maximum, slow, or timed (1 to 10 min from 0 to 500 rpm) Approximate Deceleration Time: Maximum, slow, timed (1 to 10 min from 500 to 0 rpm), or off Drive Cooling: Air Cooled Drive Type: SR* Drive Friction Reduction System (FRS): A mechanical rotary vane pump reduces chamber pressure to 0.25 ATM (190 mm [7.5 in] Hg) Maximum Heat Dissipation into Room under Steady-State Conditions: 2.0 kW (6,900 Btu/hr) Rotor ID: Auto Set Speed: Actual rotor speed ± 10 rpm from 10,000 to 26,000 rpm or equivalent RCF Set Time: 1 min to 99 hr 59 min, 2t, or continuous (hold) Speed Control: ± rpm of set speed or 0.1%, whichever is greater Speed Range: 0 to 5,000 rpm for elutriation Temperature Control: ± 2°C of set temperature (after equilibration) Zonal Capability: Yes Ambient Temperature Range: 15 to 40°C |
Beckman Coulter - Avanti J-30I
[+] View Model SpecificationsDepth | 34.5 in |
Height | 34.1 in |
Width | 28 in |
Orientation | Floor Standing |
Noise Level | 57 dB |
Weight | 680 lbs |
Speed Range | 0 to 30000 rpm |
Centrifuge Type | High Speed |
Maximum Capacity | 4 liters (Single tube Volume Range 1.5 - 1,000 mL) |
Maximum RCF | 110500 xg |
Maximum Speed | 30000 rpm |
Refrigerated | Yes_ |
Additional Model Specifications | Approximate Acceleration Time: Maximum, slow, or timed (1 to 10 min from 0 to 500 rpm) Approximate Deceleration Time: Maximum, slow, timed (1 to 10 min from 500 to 0 rpm), or off Friction Reduction System (FRS): A mechanical rotary vane pump reduces chamber pressure dependent on rotor and run speed Maximum Heat Dissipation into Room under Steady-State Conditions: 2.0 kW (6,900 Btu/hr) Set Speed: Actual rotor speed ± 10 rpm from 10,000 to 30,000 rpm or equivalent RCF Set Time: 1 min to 99 hr 59 min or continuous (hold) Temperature Control: ± 2°C of set temperature (after equilibration) Ambient Temperature Range: 16 to 38°C Clearances Required: 7.6 cm (3.0 in) sides; 16.0 cm (6.25 in) rear Door: 5.4-cm (2.1-in) thick structural foam with steel plate Humidity Restrictions: < 95% (noncondensing) Pollution Degree: 2 Rotor Chamber Diameter: 40.6 cm (16 in) Time -- Actual Display: Indicates run time remaining (timed run) or elapsed time (hold run) |
Beckman Coulter - Avanti J-E
[+] View Model SpecificationsDepth | 31.5 in |
Height | 36 in |
Width | 25 in |
Power Requirements | 50 Hz, 180 to 253 VAC, 24 A; 60 Hz, 187to229/216to264 VAC, 24 A |
Orientation | Floor Standing |
Noise Level | 64 dB |
Weight | 589 lbs |
Speed Range | 300 to 21000 rpm |
Centrifuge Type | Ultraspeed |
Maximum Capacity | 4 liters (single tube volume range: 1.5 - 1,000 mL) |
Maximum RCF | 53000 xg |
Maximum Speed | 21000 rpm |
Refrigerated | Yes CFC-Free |
Additional Model Specifications | Approximate Acceleration Time: Two profiles--MAX (full acceleration to set speed) and SLOW Approximate Deceleration Time: Three profiles--MAX, SLOW, and OFF (coast) Friction Reduction System (FRS): 190 mm (7.5 in) Hg Maximum Heat Dissipation into Room under Steady-State Conditions: 2.0 kW (6,900 Btu/hr) Set Speed: Actual rotor speed ± 50 rpm of set speed Set Time: to 99 hr 59 min or continuous (hold) Temperature Control: ± 2° C of set temperature (after equilibration) Ambient Temperature Range: 15° C to 35° C Clearances Required: 7.6 cm (3.0 in) sides; 16.0 cm (6.25 in) rear Humidity Restrictions: < 95% (noncondensing) Pollution Degree: 2 Time -- Actual Display: Indicates run time remaining/displays elapsed time Finish Control panel: silicone elastomer. Top surface: urethane paint. Other surfaces: general purpose paint. |
Beckman Coulter - J-26 XPI
[+] View Model SpecificationsDepth | 34.5 in |
Height | 34.1 in |
Width | 28 in |
Orientation | Floor Standing |
Noise Level | 57 dB |
Weight | 340 lbs |
Centrifuge Type | High Speed |
Maximum Capacity | 6 liters (single tube volume range: 1.5 - 1,000 mL) |
Maximum RCF | 82000 xg |
Maximum Speed | 26000 rpm |
Refrigerated | No_ |
Additional Model Specifications | Accel/Decel Rates 12/13 Temp Control + 2° of set temperature Speed Control + 10 rpm of set speed or 0.1%, whichever is greater Ambient Temp Range 16° to 38°C Drive Type Cooling SRDrive / Air Cooled Power Usage / Heat Output 2.0 kW / 6900 Btu/hr |