GenTech Scientific - GenTech MS-QuietBox II

Manufactured by  GenTech Scientific
Follow this Equipment

The GenTech MS-QuietBox II™ system offers a wide range of ventilated noise reduction solution for all brands of...

The GenTech MS-QuietBox II™ system offers a wide range of ventilated noise reduction solution for all brands of mass spec vacuum pumps including Edwards, Leybold and Varian.   
   
Noise levels from a single vacuum pump can reach up to 75 db(A) and with multiple systems in a single lab this can increase considerably. The MS-QuietBox II™ is available as either a single or double pump enclosure and will reduce the noise levels by 15db(A).   
   
The innovative design allows for installation with no need to shut the instrument down and multiple options for pipework access enables quick setup and easy access for maintenance. The MS-QuietBoxII™ integral fans maintain the pumps at an optimum temperature and additional safety options are available to suit individual requirements. The unique flat-pack construction is environmentally friendly, reducing shipping costs and can be assembled in 5 minutes with no need for tools.
Active Questions & AnswersAsk a Question

There are no current Discussions

Other MS Service ProvidersView All (41)

Request Support
Documents & Manuals

There are no Documents or Manuals available.

Features of GenTech MS-QuietBox II
  • Reduce pump noise by 15 db(A   * Install without Mass Spec downtime   * Three options for pipework access points for easy setup   * Integral fans maintains vacuum pump at optimum temperature (safety options available)   * Compatible with all common LCMS vacuum pumps   * Easy access for pump maintenance   * Flatpack delivery, can be assembled in 5 minutes - no tools required   * CE Marked   * Dimensions
General Specifications
Depth 614 mm
Height605 mm
Width 414 mm
Additional Specifications

MS-QuietBox II - Part No#MSQB2-01T - for the following pumps:   

  • Edwards RV3, RV5, XDS5, E2M0.7, E2M1.5   
  • Leybold S1, 5, D2, 5E and Triscoll 300/600   
  • Ulvac G100DC, Ulvac GLD040   
  • Duo 2.5 Pfeiffer   
  • Varian MS40+   
       
    MS-QuietBox II - Part No#MSQB2-02T - for the following pumps:
       
  • Edwards RV8, RV12, E1M18, E2M18, E2M28, E2M30   
  • Leybold Trivac D25B, D16B, D4B, D8B, D16B   
  • Varian DS42, DS102, DS202, DS302, DS402, DS602, HS602, HS452, HS652   
  • Alcatel 1005SD, 1015SD, 2004A, 2005SD   
       
  • Pump Tray   
  • NINETY (90) DAY WARRANTY
  • Looking for New or Used Equipment?

    Shop on LabX

    Shop on Labx.com