TOMY - LC-200/220/230

Manufactured by  TOMY
Follow this Equipment

Easy-Mount Rotors>Tomy offers a wide selection of Easy-Mount Rotors for the Flexpin Bench-top centri...

Easy-Mount Rotors
Tomy offers a wide selection of Easy-Mount Rotors for the Flexpin Bench-top centrifuges. These rotors install and remove with the turn of a knob and the selection covers most of the commonly used centrifuge labware.

Flex-Spin Drive
The Flex-Spin Drive features a flexible motor shaft that equalizes minor imbalances without damaging the centrifuge or triggering the imbalance protection system. This allows excellent tolerance for minor difference in sample volumes.

Superior Imbalance Protection
Tomy has developed a unique concept in imbalance protection based on the kinetic energy generated by the entire rotational system including the motor, rotor, buckets and adapters. This system, with its expanded inputs, is capable of detecting a severe imbalance within a few seconds after the centrifuge is started.

Higher Speeds for Microplates
The TS-38LB rotor and B438-96 buckets spin four 96-well microplates at 4,200 rpm generating 3,100G - sufficient for microplate based ethanol extractions of DNA.

High-Speed Fixed Angle Rotor
The TLA-11 Fixed Angle Rotor is a high-speed rotor that takes up to six 35 to 50 ml conical centrifuge tubes, and generates up to 9,600G. The maximum speeds will depend on the tube manufacturers' specifications.

Flat Tabletop
No Chamber Gasket on the tabletop provides easy sample load.
Active Questions & AnswersAsk a Question

There are no current Discussions

Centrifuge Service ProvidersView All (22)

Request Support
Documents & Manuals

There are no Documents or Manuals available.

Features of LC-200/220/230

Safety Devices

  • Imbalance Detector
  • Scatter Containing Lid System
  • Rotor Identification System
  • Lid Interlock System
  • Lid Detector
  • Overspeed Detector
  • Motor Overheat Detection
  • Overcurrent Detection
  • Circuit Detector
General Specifications

There are no General Specifications available.

Additional Specifications

Model LC-200
Maximum Speed 9,000rpm
Maximum RCF 9,600G
Maximum Capacity 480ml (15ml x 32)
Speed Control Microprocessor
Drive System Flex-Spin Drive System
Speed Display 0 to 9,990rpm
Setting Range 300 to 9,000rpm
Control Precision Setting Speed +/-50rpm
Force
Display/ Display Range
Digital / 0 to 9,990G
Setting Range 10 to 9,600G
(Less than 100G : Units of 10G, More than 100G : Units 100G)
Time
Display/ Display Range Digital / 0 to 99 minutes, or Cotinuous
Setting Range 1 to 99 minutes, or Continuous
Precision Within 0.1% or 1 second
Other Functions
3 Acceleration and Deceleration Steps(LC-220/230)/2 Deceleration Steps(LC-200),
Rotor Speed Automatic Setting with BART Code, Previous Setting Memory,
5 Memory Stores(LC-220/230)/2 Memory Stores (LC-200)
Safety Devices Imbalance Detector, Scatter Containing Lid System, Rotor Identification System,
Lid Interlock System, Lid Detector, Overspeed Detector,
Motor Overheat Detection, Overcurrent Detection, Circuit Detector
Required Environment Room Temperature : 6 to 35 degree C, Relative Humidity : 30 to 85 %
Dimentions
420W x 528(projection 95)D x 337H mm
Height to the Chamber : 300 mm
Net Weight Approx. 46 kg
Power Required
110/120V, 15A, 50/60Hz
220/230/240V, 8A, 50/60Hz
Consumptive Electric Power 470 W

Model LC-220
Maximum Speed 9,000rpm
Maximum RCF 9,600G
Maximum Capacity 480ml (15ml x 32) 1,200ml (15ml x 80)
Speed Control Microprocessor
Drive System Flex-Spin Drive System
Speed Display 0 to 9,990rpm
Setting Range 300 to 9,000rpm
Control Precision Setting Speed +/-50rpm
Setting Range 10 to 9,600G
(Less than 100G : Units of 10G, More than 100G : Units 100G)
Time Display 0 to 99 minutes, or Cotinuous
Setting Range 1 to 99 minutes, or Continuous
Precision Within 0.1% or 1 second
Other Functions 3 Acceleration and Deceleration Steps(LC-220/230)/2 Deceleration Steps(LC-200),
Rotor Speed Automatic Setting with BART Code, Previous Setting Memory,
5 Memory Stores(LC-220/230)/2 Memory Stores (LC-200)
Safety Devices Imbalance Detector, Scatter Containing Lid System, Rotor Identification System,
Lid Interlock System, Lid Detector, Overspeed Detector,
Motor Overheat Detection, Overcurrent Detection, Circuit Detector
Required Environment Room Temperature : 6 to 35 degree C, Relative Humidity : 30 to 85 %
Dimentions 440W x 544(projection 95)D x 362H mm
Height to the Chamber : 300 mm Height to the Chamber : 325 mm Height to the Chamber : 328 mm
Net Weight Approx. 50 kg
Power Required
110/120V, 15A, 50/60Hz
220/230/240V, 8A, 50/60Hz
Consumptive Electric Power 600 W

Model LC-230
Maximum Speed 9,000rpm
Maximum RCF 9,600G
Maximum Capacity 1,200ml (15ml x 80)
Speed Control Microprocessor
Drive System Flex-Spin Drive System
Speed
Display/ Display Range Digital / 0 to 9,990rpm
Setting Range 300 to 9,000rpm
Control Precision Setting Speed +/-50rpm
Force
Display/ Display Range Digital / 0 to 9,990G
Setting Range 10 to 9,600G
(Less than 100G : Units of 10G, More than 100G : Units 100G)
Time
Display/ Display Range Digital / 0 to 99 minutes, or Cotinuous
Setting Range 1 to 99 minutes, or Continuous
Precision Within 0.1% or 1 second
Other Functions 3 Acceleration and Deceleration Steps(LC-220/230)/2 Deceleration Steps(LC-200),
Rotor Speed Automatic Setting with BART Code, Previous Setting Memory,
5 Memory Stores(LC-220/230)/2 Memory Stores (LC-200)
Safety Devices Imbalance Detector, Scatter Containing Lid System, Rotor Identification System,
Lid Interlock System, Lid Detector, Overspeed Detector,
Motor Overheat Detection, Overcurrent Detection, Circuit Detector
Required Environment Room Temperature: 6 to 35 degree C, Relative Humidity : 30 to 85 %
Dimentions 484W x 582(projection 95)D x 365H mm
Height to the Chamber : 328 mm
Net Weight Approx. 54 kg
Power Required
110/120V, 15A, 50/60Hz
220/230/240V, 8A, 50/60Hz
Consumptive Electric Power 730 W

Series Modals

TOMY - LC-200

[+] View Model Specifications

TOMY - LC-220

[+] View Model Specifications

TOMY - LC-230

[+] View Model Specifications