Features of AX Series
FLEXIBILITY
- From mircro tubes to 250ml bottles
- Convenient flashing function
- Three-step acceleration and three-step and natural deceleration
COMPACT DESIGN
- Compact design for minimum space requirement
EASY OPERATION
- Easy to see and operate control panel
SAFETY & ECOLOGY
- One-push rotor locking knob* Flap-drive system for safer and more efficient operation
General Specifications
There are no General Specifications available.
Additional Specifications
Model AX-310
Maximum Speed 9,000rpm
Maximum RCF 9,600G
Maximum Capacity 1,000ml (4x250ml)
Control System Microprocessor control (feedback system)
Drive Motor Induction motor
Setting System Jog Dial with (ENTER) button on top
Temperature Display Digital
Setting Range From -9 to +35 degree C, 1 degree C increments
Control Range From -9 degree C to ambient temperature
Speed Display Digital (from 0rpm to 9,990rpm)
Setting Range From 100rpm to 9,000rpm, 100rpm increments
RCF Display Digital (from 0G to 9,990G)
Setting Range From 10 to 9,600G, 10G increments for the range less than 100G,
100G increments for the range over 100G
Time Display Digital (from 0sec to 59sec and 1min to 99min. Or for free)
Setting Range From 10 sec to 50 sec, in 10 sec increments, from 1min to 99min, in 1min increments of for free
Refrigerant HFC134a
Safety Devices Imbalance detector, Over-speed detector, Motor over-current detector, Lid interlock, Over-current circuit breaker, Abnormally high or low chamber temperature detector, Lid open/close detector, Rotor identification system
Additional Functions
Three-step acceleration characteristics selection, BART code selection, Four programmable memory function, Three-step deceleration charactiristics selection, FLASH operation function
Weight/ Power Requirements 125kg/
Single phase AC120V, 50/60Hz, 15A 130kg/
Single phase AC220/230/240V, 50/60Hz, 8A
Power Consumption(Heat output) 930W (800kcal/h)
Dimensions 510W x 590D x 940H mm,(table height; 775mm)
Model AX-320
Maximum Speed 9,000rpm
Maximum RCF 9,600G
Maximum Capacity 1,536ml (8x96x2ml DW plate)
Control System Microprocessor control (feedback system)
Drive Motor Induction motor
Setting System Jog Dial with (ENTER) button on top
Temperature Display Digital
Setting Range From -9 to +35 degree C, 1 degree C increments
Control Range From -9 degree C to ambient temperature
Speed
Display Digital (from 0rpm to 9,990rpm)
Setting Range From 100rpm to 9,000rpm, 100rpm increments
RCF
Display Digital (from 0G to 9,990G)
Setting Range From 10 to 9,600G, 10G increments for the range less than 100G,
100G increments for the range over 100G
Time
Display Digital (from 0sec to 59sec and 1min to 99min. Or for free)
Setting Range From 10 sec to 50 sec, in 10 sec increments, from 1min to 99min, in 1min increments of for free
Refrigerant HFC134a
Safety Devices Imbalance detector, Over-speed detector, Motor over-current detector, Lid interlock, Over-current circuit breaker, Abnormally high or low chamber temperature detector, Lid open/close detector, Rotor identification system
Additional Functions
Three-step acceleration characteristics selection, BART code selection, Four programmable memory function, Three-step deceleration charactiristics selection, FLASH operation function
Weight/ Power Requirements 134kg/
Single phase AC120V, 50/60Hz, 15A139kg/
Single phase AC220/230/240V, 50/60Hz, 8A
Power Consumption(Heat output) 1,030W (890kcal/h)
Dimensions 540W x 620D x 940H mm,(table height; 775mm)
Series Modals
TOMY - AX-310
[+] View Model SpecificationsDepth | 590 mm |
Height | 940 mm |
Width | 510 mm |
Power Requirements | Single phase: AC120V, 50/60Hz, 15A 130kg/ - AC220/230/240V, 50/60Hz, 8A |
Orientation | Floor Standing |
Weight | 125 kg |
Speed Range | 0 to 9990 rpm |
Centrifuge Type | Low Speed |
Maximum Capacity | 1,000ml (4x250ml) |
Maximum RCF | 9600 xg |
Maximum Speed | 9990 rpm |
Refrigerated | Yes_ |
Additional Model Specifications | Control System: Microprocessor control (feedback system) Drive Motor: Induction motor Setting System: Jog Dial with (ENTER) button on top Temperature Display: Digital Control Range: From -9 degree C to ambient temperature Setting Range: From 100rpm to 9,000rpm, 100rpm increments Setting Range: From 10 to 9,600G, 10G increments for the range less than 100G, 100G increments for the range over 100G Time: Display Digital (from 0sec to 59sec and 1min to 99min. Or for free) Setting Range: From 10 sec to 50 sec, in 10 sec increments, from 1min to 99min, in 1min increments of for free Refrigerant: HFC134a Safety Devices: Imbalance detector, Over-speed detector, Motor over-current detector, Lid interlock, Over-current circuit breaker, Abnormally high or low chamber temperature detector, Lid open/close detector, Rotor identification system Additional Functions: Three-step acceleration characteristics selection, BART code selection, Four programmable memory function, Three-step deceleration charactiristics selection, FLASH operation function Power Consumption(Heat output): 930W (800kcal/h) |
TOMY - AX-320
[+] View Model SpecificationsDepth | 620 mm |
Height | 940 mm |
Width | 540 mm |
Power Requirements | Single phase: AC120V, 50/60Hz, 15A139kg/ - AC220/230/240V, 50/60Hz, 8A |
Orientation | Floor Standing |
Weight | 134 kg |
Speed Range | 0 to 9990 rpm |
Centrifuge Type | Low Speed |
Maximum Capacity | 1,536ml (8x96x2ml DW plate) |
Maximum RCF | 9600 xg |
Maximum Speed | 9990 rpm |
Refrigerated | Yes_ |
Additional Model Specifications | Control System: Microprocessor control (feedback system) Drive Motor: Induction motor Setting System: Jog Dial with (ENTER) button on top Temperature Display; Digital Control Range: From -9 degree C to ambient temperature RCF: Setting Range: From 10 to 9,600G, 10G increments for the range less than 100G, 100G increments for the range over 100G Time: Display Digital: (from 0sec to 59sec and 1min to 99min. Or for free) Setting Range: From 10 sec to 50 sec, in 10 sec increments, from 1min to 99min, in 1min increments of for free Refrigerant: HFC134a Safety Devices: Imbalance detector, Over-speed detector, Motor over-current detector, Lid interlock, Over-current circuit breaker, Abnormally high or low chamber temperature detector, Lid open/close detector, Rotor identification system Additional Functions: Three-step acceleration characteristics selection, BART code selection, Four programmable memory function, Three-step deceleration charactiristics selection, FLASH operation function Power Consumption(Heat output): 1,030W (890kcal/h) |