Beckman Coulter - Allegra X-15R

Manufactured by  Beckman Coulter
Follow this Equipment

More Power! More Flexibility!...On the Bench!

The X-15R spins up to three liters of sample at an industry-leading 5,250 x g, with a robust refrigeration system that cools from ambient to 4C in less than 4 minutes – over 10 minutes faster than other three liter centrifuges. Save even more time with optional ARIES rotor technology that accepts up to 50 grams (effectively one tube!) of rotor imbalance, allowing you to eye-balance your samples with confidence. The X-15R is the ideal choice for all your cellular separation applications.
Active Questions & AnswersAsk a Question

Recent Questions & Answers

avatar placemark

Asked bySteveBrok

avatar placemark

Asked byxuefei

avatar placemark

Asked byardhi

Centrifuge Service ProvidersView All (21)

Request Support
Features of Allegra X-15R

4 x 750 mL Swinging Bucket Rotor . . . 5,250 x g!    

Now faster separations in your 4 x 750 mL rotor than ever before    

  • Optimize recoveries    
  • Faster separations    
  • Save time    

Some Key Applications Include     Filtration and Concentration    

  • 3 mL and larger centrifugal devices    
  • At maximum speed in your swinging bucket rotor    

Fast & Slow Blood Component Spins    

Microbial Cell Harvesting    

  • Up to 3 liters    
  • In just 14 minutes    

Skip Steps in Cell Culturing     Centrifuge cells directly in your cell culture flasks    

  • Save time and labor    
  • Eliminate 15 mL or 50 mL conical tubes    
  • Reduce a potential contamination step
General Specifications
Centrifuge Type Clinical
Maximum RCF11400 xg (Fixed Angle Rotor)
Maximum Speed4750 rpm (Swinging Bucket Rotor)
OrientationBenchtop
RefrigeratedYes CFC-Free
Depth 24.5 in
Height13.5 in
Width 30 in
Power Requirements 60 Hz, 208V
Weight283 lbs
Additional Specifications

Approximate Acceleration Time: 10 acceleration   
Approximate Deceleration Time: 11 deceleration   
Drive Type: Brushless Induction   
   
Max Speed    
Swinging Bucket Rotor: 4,750 rpm   
Fixed Angle Rotor: 10,200 rpm   
   
Temperature Control: -10° C to +40° C   
Acceleration: 10 Profiles   
Audible End-of-Run Tone: Yes   
Automatic Rotor Identification: Yes   
Deceleration: 11 Profiles   
Timed Run: Up to 99 hours, 59 min   
User-Defined Programs: 10   
Ventilation Clearances Required: Sides and Rear: 7.6 cm (3.0 in)   
   
Relative Centrifugal Field (RCF) at r max:    
Swinging Bucket Rotor: 5,250 x g   
Fixed Angle Rotor: 11,400 x g   
   
Rotor Capacity: 4 x 750 mL

VideosView All Videos
  • Allegra X-15R Centrifuge Performance Overview by Beckman Coulter

Looking for New or Used Equipment?

Shop on LabX

Shop on Labx.com