This product is Discontinued
Beckman Coulter - Allegra X-22 Series
Manufactured by Beckman Coulter
The compact Allegra X-22 Series is up to 10 inches/ 25 cm thinner than other benchtop centrifuges. With a library of 11...
The compact Allegra X-22 Series is up to 10 inches/ 25 cm thinner than other benchtop centrifuges. With a library of 11 rotors, the Allegra X-22 Series is the
space-saving multipurpose solution for your requirements.
space-saving multipurpose solution for your requirements.
Active Questions & AnswersAsk a Question
Centrifuge Service ProvidersView All (22)
Documents & ManualsView All Documents
Features of Allegra X-22 Series
- Only 18 inches / 46 cm wide
- 11 Rotor Library
- Achieve up to 22,065 x g
3 different ways to Spin 1.5 mL & PCR* Tubes:
- 24-place fixed-angle Rotor - 22,065 x g Certified by Porton Down UK
- 30-place Fixed-angle Rotor - 21,952 x g
- 24-place Swinging-bucket Rotor - 16,244 x g for Flat Pelleting
One Rotor Spins 500 uL to 250 mL
- 4 x 250 mL - Maximum Capacity
- 4,500 rpm - 3,901 x g - Maximum g-Force
- 18 Different Adapters
Spins
- 250 mL Bottles
- 100 mL, 94 mL, 85 mL Bottles
- 50 mL Conical and Round-bottom Tubes
- 15 mL Conical and Round-bottom Tubes
- 30 mL, 25 mL, 10 mL Tubes
- 1.5 mL and 500 µL PCR Tubes
General Specifications
There are no General Specifications available.
Additional Specifications
Dimensions(in) Lid Closed: 18.1W x 21.7D x 14H
Weight without Rotor: 48 kg (106 lbs)
Maximum g-Force: 19,309 x g
Maximum Capacity: 4 x 250 mL
Series Modals
Beckman Coulter - Allegra X-22
[+] View Model SpecificationsDepth | 21.7 in |
Height | 14 in |
Width | 18.1 in |
Orientation | Benchtop |
Weight | 48 |
Centrifuge Type | Clinical |
Maximum Capacity | 4 x 250 m |
Maximum RCF | 19309 xg |
Maximum Speed | 14500 rpm |
Refrigerated | No_ |
Additional Model Specifications | Run Time: Timed (Up to 9 hrs, 59 min) Hold, Pulse (Short Run) Drive: Brushless Induction Accel/Decel Profiles: 10/10 Operating Temperature: Ambient *Weight without Rotor |
Beckman Coulter - Allegra X-22R
[+] View Model SpecificationsDepth | 70.7 cm |
Height | 37 cm |
Width | 46 cm |
Orientation | Benchtop |
Weight | 78 kg |
Centrifuge Type | Clinical |
Maximum Capacity | 4 x 250 mL |
Maximum RCF | 22065 xg |
Maximum Speed | 15500 rpm |
Refrigerated | Yes CFC-Free |
Additional Model Specifications | Run Time: Timed (Up to 9 hrs, 59 min) Hold, Pulse (Short Run) Drive: Brushless Induction Accel/Decel Profiles: 10/10 Operating Temperature: +2°C to +40°C *Weight without rotor |