Waters - Atmospheric Solids Analysis Probe

Manufactured by  Waters
Follow this Equipment

Rapid Direct Analysis of Volatile and Semi-Volatile, Solid and Liquid Samples

The Atmospheric Solids Analysis Probe (ASAP) (introduced by McEwan et al) is a useful tool for the rapid direct analysis of volatile and semi-volatile, solid and liquid samples using atmospheric pressure ionization. 
 
The ASAP technique utilizes the heated nitrogen desolvation gas to vaporize the sample and a corona discharge for sample ionization. This allows low polarity compounds not amenable to ESI, APcI and APPI to be ionized with a high degree of sensitivity. Furthermore complex mixtures can be analyzed without the need for any sample preparation.
Active Questions & AnswersAsk a Question

There are no current Discussions

Other MS Service ProvidersView All (41)

Request Support
Documents & Manuals

There are no Documents or Manuals available.

Features of Atmospheric Solids Analysis Probe

Sensitivity and Safety by Design  The Waters Atmospheric Solids Analysis Probe is readily fitted to a standard API source by replacing either the ESI or APCI probe assembly. A corona discharge pin also requires fitting. The close proximity of the sample, when loaded onto a glass capillary tube, to the point of ionization and the MS inlet, improves sensitivity while also ensuring safety due to the enclosed source housing. 

Instruments are operated in combined Electrospray/APcI mode (ESCi®). This provides for the acquisition of both analyte data in APcI mode and reference data in electrospray mode, enabling exact mass measurements to be produced. 

The probe is designed to have both fixed and removable sections to allow rapid sample introduction without removal of the complete assembly ensuring stable source conditions.

General Specifications

There are no General Specifications available.

Additional Specifications

Equipment and Installation 
The Atmospheric Solids Analysis Probe accessory comprises the probe body with removable sample insertion probe assembly, corona pin, glass sample capillaries, and operator's guide. Additional software (included) is also required for selected instruments. 
 
There are two versions of probe, depending on the design of the instrument's API source assembly. 
 
The probes are user-installable. However engineer installation and operation confirmation and training is available and recommended. 
 
Instrument Compatibility 
The Atmospheric Solids Analysis Probe is compatible and supported with the following instruments: 

     
  1. ACQUITY® SQD/TQD 
  2. LCT PremierTM (upgraded to ESCi or IonSABRETM APcI/ESCi exact mass) 
  3. LCT Premier XE 
  4. Q-Tof PremierTM, MALDI Q-Tof Premier 
  5. (MALDI) SYNAPTTM MS , (MALDI) SYNAPT HDMSTM 
  6. SQ Detector 2/Xevo TQD 
  7. Xevo TQ MS, Xevo TQ-S, Xevo TQ-S micro 
  8. Xevo G2 Tof, Xevo G2-S Tof, Xevo G2-XS Tof 
  9. Xevo QTof™ MS, Xevo G2 QTof, Xevo G2-S QTof, Xevo G2-XS QTof 
  10. (MALDI) SYNAPT G2 MS, (MALDI) SYNAPT G2 HDMS 
  11. (MALDI) SYNAPT G2-S MS, (MALDI) SYNAPT G2-S HDMS 
  12. (MALDI) SYNAPT G2-Si MS, (MALDI) SYNAPT G2-Si HDMS 