A&D Weighing - EK-EP Series
Manufactured by A&D Weighing
Intrinsically Safe Compact Balances
Compact, lightweight and affordable.
FM & FMc approved for excellent explosion protection. Portable and battery powered, requiring no power supply from a safe area. Get it today and start using it today.
Stay safe.
Active Questions & AnswersAsk a Question
There are no current Discussions
Balances Service ProvidersView All (23)
Documents & ManualsView All Documents
Features of EK-EP Series
- Intrinsically Safe (FM Approved)
- 200+ Hours of Battery Life
- Counting & Comparator function
- Auto Power-Off Function
- LCD Backlight Display
General Specifications
There are no General Specifications available.
Series Modals
A&D Weighing - EK-12KEP
[+] View Model SpecificationsPlate Depth | 5.24 in |
Plate Width | 6.69 in |
Capacity | 12 kg |
Weight | 1.5 kg |
Linearity | 1 g |
Minimum Load | 1 g |
Readability | 1 g |
Repeatability | 1 g |
Additional Model Specifications | Sensitivity drift ±20 ppm /°C (10°C-30°C / 50°F-86°F) Counting Mode No. of samples: 5, 10, 25, 50 or 100 pieces Percent Mode Min. % display: 0.1% Min. 100% weight: 100 g Operating temperature range 0°C-40°C / 32°F-104°F, less than 85% R.H. (non-condensing) Class / division standards IS / I / 1 / C,D / T3C Zone standards - FM/FMc Aex / Ex ia IIB T3 Battery operation Approximately 250 hours (with 4 AA alkaline batteries, backlight off) |
A&D Weighing - EK-3000EP
[+] View Model SpecificationsPlate Depth | 5.24 in |
Plate Width | 6.69 in |
Capacity | 3000 g |
Weight | 1.5 kg |
Linearity | 0.2 g |
Minimum Load | 0.1 g |
Readability | 0.1 g |
Repeatability | 0.1 g |
Additional Model Specifications | Sensitivity drift ±20 ppm /°C (10°C-30°C / 50°F-86°F) Counting Mode No. of samples: 5, 10, 25, 50 or 100 pieces Percent Mode Min. % display: 0.1% Min. 100% weight: 10 g Operating temperature range 0°C-40°C / 32°F-104°F, less than 85% R.H. (non-condensing) Class / division standards IS / I / 1 / C,D / T3C Zone standards - FM/FMc Aex / Ex ia IIB T3 Battery operation Approximately 250 hours (with 4 AA alkaline batteries, backlight off) |
A&D Weighing - EK-300EP
[+] View Model SpecificationsPlate Depth | 4.33 in |
Plate Width | 4.33 in |
Capacity | 300 g |
Weight | 1.2 kg |
Linearity | 0.02 g |
Minimum Load | 0.01 g |
Readability | 0.01 g |
Repeatability | 0.01 g |
Additional Model Specifications | Sensitivity drift ±20 ppm /°C (10°C-30°C / 50°F-86°F) Counting Mode No. of samples: 5, 10, 25, 50 or 100 pieces Percent Mode Min. % display: 0.1% Min. 100% weight: 1 g Operating temperature range 0°C-40°C / 32°F-104°F, less than 85% R.H. (non-condensing) Class / division standards IS / I / 1 / C,D / T3C Zone standards - FM/FMc Aex / Ex ia IIB T3 Battery operation Approximately 250 hours (with 4 AA alkaline batteries, backlight off) |